THIS IS MY SELECT
ATS ATC Breaker / Contactor
ATC Contactor-Based Automatic Transfer Switch
Rating Range
93.0 hp
40-1600A
Transfer Type
93.0 hp
Open / Closed Transition
Switch Type
93.0 hp
Contactor Based
THIS IS MY SELECT
backhoe loader
ATC Contactor-Based Automatic Transfer Switch
Rating Range
93.0 hp
40-1600A
Transfer Type
93.0 hp
Open / Closed Transition
Switch Type
93.0 hp
Contactor Based
Specifications
Cat® transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. The open and delayed transition contactor-based Automatic Transfer Switch (ATS) provides fully functioning transfer in Applications where a momentary loss of power is acceptable during transfer and retransfers between normal and emergency power supply. The closed transition contactor-based ATS is designed to Meet application requirements where emergency back up power is required with no momentary loss of power by connecting both sources before the transfer occurs. Closed transition also permits periodic testing of the emergency power source without interrupting power to the loads.
-
Rating Range
93.0 in
93.0 mm
40-1600A
Transfer Type
93.0 in
93.0 mm
Open / Closed Transition
Switch Type
93.0 in
93.0 mm
Contactor Based
-
Control Power
93.0 in
93.0 mm
Wall Mount 40-600A 2 or 3 Pole Floor Standing 600A 4 Pole & 800-1200A 2, 3, or 4 Pole
Two-Position Contactors
93.0 in
93.0 mm
Two-position contactors 40-400A
Three-Position Contactors
93.0 in
93.0 mm
Three-position contactors 40-1200A
System Voltage Application
93.0 in
93.0 mm
Up to 600 Vac, 50/60 Hz
Applicable Testing
93.0 in
93.0 mm
UL 1008 listed, CSA C22.2 No. 178 certified, IBC 2006, CBC 2007 and OSHPD
-
Contact Composition
-
Controls and Wiring
-
Enclosure
-
Available Options
-
2- or 4-position test switch
-
Controller availability: ATC-100, ATC-300+,and ATC-800
-
Delayed transition or closed transition
-
Multi-meter options available
-
Surge suppression
-
Space heaters
-
Field selectable, multi ratio, control voltage transformer 50/60 Hz
-
Selectable automatic or non-automatic operation
-
Remote communications
-
Load shed from emergency
-
-
Optional Delayed Transition includes:
-
Pre-transfer signal with 1 N.O. and 1 N.C. contacts
-
Time delay neutral
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance