THIS IS MY SELECT

Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating

93.0 hp

2000 kVA

Prime Power Rating

93.0 hp

1825 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel Consumption

THIS IS MY SELECT

backhoe loader

3516 Diesel Generator Set

Standby Rating

93.0 hp

2000 kVA

Prime Power Rating

93.0 hp

1825 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel Consumption

Specifications

The 3516 generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

      • Standby Rating

        93.0 in

        93.0 mm

        2000 kVA

        Prime Power Rating

        93.0 in

        93.0 mm

        1825 kVA

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Low Fuel Consumption

        Voltage

        93.0 in

        93.0 mm

        380 to 415 Volts

        Frequency

        93.0 in

        93.0 mm

        50 Hz

        Speed

        93.0 in

        93.0 mm

        1500 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Mission Critical, Prime, Continuous

        Maximum Rating

        93.0 in

        93.0 mm

        2000 kVA

        Minimum Rating

        93.0 in

        93.0 mm

        1600 kVA

      • Engine Model

        93.0 in

        93.0 mm

        3516 TA, V-16, 4-Stroke Water-Cooled Diesel

        Bore

        6.69 in

        170 mm

        Stroke

        7.48 in

        190 mm

        Displacement

        4,210.64 in³

        69 l

        Compression Ratio

        93.0 in

        93.0 mm

        13.0:1

        Aspiration

        93.0 in

        93.0 mm

        TA

        Fuel System

        93.0 in

        93.0 mm

        Mechanical unit injection

        Governor Type

        93.0 in

        93.0 mm

        Woodward

      • Length - Maximum

        234.4 in

        5,953 mm

        Width - Maximum

        90 in

        2,286 mm

        Height - Maximum

        94.9 in

        2,410 mm

        Dry Weight - Genset (maximum)

        33,840 lb

        15,350 kg

      • Air Inlet System

      • Governing System

      • Control System

        • Auto / start / stop control

        • EMCP 4.2B

        • Environmental sealed front face

        • Generator mounted - rear facing

        • Speed adjust

        • 24 Volt DC operation

        • Generator set packages include Caterpillar's Voltage Regulator

        • Text alarm/event descriptions

        • Emergency stop pushbutton

        • Engine cool-down timer

        • Engine cycle crank

        • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor

        • Controls:

        • Alarm acknowledge

        • Lamp test

        • PLC functionality

        • Load histogram feature

        • 3 Analog inputs

        • Operating hours

        • Serial annunciator module data link

        • Digital indication for:

        • 4 programmable relay outputs (Form A)

        • ATAAC - 3516E Package Radiators shipped installed

        • Communications:

        • Customer data link (Modbus RTU)

        • Reverse Reactive Power (kVAr) (32RV)

        • Accessory module data link

        • Number of I/O varies on options selected:

        • RPM

        • Overcurrent (50/51)

        • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy

        • 1 programmable relay outputs (Form C)

        • 1 programmable digital outputs

        • Cat Connect

        • 6 Customer programmable digital inputs

        • Certified standard PGS provided

        • Volts (L-L & L-N)

        • Coolant temperature

        • Oil pressure (psi, kPa or bar) - Coolant temperature - Volts (L-L & L-N) - Frequency (Hz) - Amps (per phase & average) - Power Factor (per phase & average) - kW (per phase, average & percent) - kVA (per phase, average & percent) - kVAr (per phase, average & percent) - kW-hr (total) - kVAr-hr (total)

        • Frequency (Hz)

        • kVA (per phase, average & percent)

        • Amps (per phase & average)

        • Power Factor (per phase & average)

        • kVAr (per phase, average & percent

        • kW (per phase, average & percent

        • kW-hr (total)

        • kVAr-hr (total)

        • Failure to start (overcrank)

        • Emergency stop

        • Overspeed

        • Warning/shutdown with common LED indication of shutdowns for:

        • High coolant temperature

        • Low oil pressure

        • Programmable protective relaying functions

        • Low coolant level

        • Low coolant temperature

        • Generator phase sequence

        • Over / Under frequency (81 o/u)

        • Over / Under voltage (27/59)

        • Reverse Power (kW) (32)

      • Exhaust System

        • Dry exhaust manifold

        • Flanged faced outlet(s)

      • Fuel System

        • Fuel priming pump

        • Flexible fuel lines - shipped loose

        • Secondary fuel filters

        • Fuel cooler; not included with packages without radiator

      • General

        • Right hand servicing

        • Flywheel and flywheel housing - SAE No. 00

        • Caterpillar yellow with high gloss black rails and radiator

        • SAE standard rotation

      • Generator and Attachments

        • Winding temperature detectors

        • Bus bar connections, right side extension box, bottom cable entry

        • Permanent magnet

        • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby

        • Busbar connections, top center mounted, top cable entry

        • Anti Condensation Space Heater

        • NEMA standard hole pattern

        • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)

        • Low Voltage:

        • Winding temperature detectors

        • Form wound

        • Medium Voltage:

        • Winding temperature detectorsle pattern

        • NEMA standard hole pattern

        • Six lead

        • Form wound

        • Internal Excitation

        • 3 Phase brushless, salient pole

        • Random wound

        • Busbar connections, top center mounted, top cable entry

        • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)

        • High Voltage:

      • Literature

      • Lubrication System

        • Oil drain lines and valve

        • Lubricating oil

        • Gear type lube oil pump

        • Integral lube oil cool

        • Fumes disposal

        • Oil filter, filler and dipstick

      • Mounting System

        • Rails - engine / generator / radiator mounting

        • Rubber anti-vibration mounts (shipped loose)

        • Anti-vibration mounts (shipped loose)

      • Starting System

        • 24 Volt electric starting motor

        • 45 Amp charging alternator

        • Battery disconnect switch

        • Battery and battery rack w/cables

      • Control System

        • Local annunciator module: [ ] NFPA 110 [ ] Custom

        • EMCP 4.3, EMCP 4.4

      • Air Inlet System

        • Dual element air cleaner

        • Single element filter

      • Cooling System

        • Water level switch gauges

        • Coolant

        • Standard ambient radiators

        • Standard ambient ATAAC radiators

        • Optional installed ATAAC radiators

        • Optional installed radiators

      • Engine Options

        • Starting Aids: [ ] 220V 50 Hz Jacket Water Heater

        • Air Cleaner: [ ] Single element air cleaners [ ] Dual element air cleaners [ ] Heavy duty air cleaners

        • Batteries: [ ] Standard (1400 CCA) [ ] Heavy Duty (2800 CCA)

        • Starting Motors: [ ] Standard [ ] Heavy Duty

        • Muffler: [ ] Industrial Grade

      • Crankcase System

        • Explosion relief valves

        • Ventilation system

        • No explosion relief valves

      • Alternators

      • Exhaust System

        • Y-Adapters

        • Exhaust offset

        • Tier 4 dosing cabinet

        • Flexible fittings

        • Elbows

        • Clean emission parts

        • Tier 4 clean emissions module

        • Flanges

        • Tier 4 clean emission MOD Kits

        • Mufflers

        • Flange and exhaust expanders

      • Fuel System

        • Fuel Priming Pumps (Tier 4) - Manual or electric

        • Primary Fuel Filter

      • General

        • UL 2200 package

        • US aid emblem

        • Special paint (Colors other than Caterpillar yellow or high performance paints)

        • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

        • The following options are based on regional and product configuration:

      • Power Termination

        • Circuit breaker operation: [ ] Electrical

        • Circuit breaker trip unit: [ ] LSI [ ] LSIG [ ] LSIG-P

        • Power Termination: [ ] Busbar [ ] Circuit Breaker

        • Circuit Breaker rating: [ ] 2000A [ ] 2500A [ ] 3200A [ ] 4000A

      • Generators and Attachments

        • Low / medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

        • Low / medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame

        • Space heater

        • Differential current transformers (DCT)

        • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

        • Generator conversion

        • Differntial current transformers (DCT) 8.7 kV and 15 kV classes

        • Thermostate for space heater

        • Alternator air cleaner

        • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

        • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

        • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

      • Extended Service Contract (ESC)

      • Instrumentation

      • Lubrication System

        • Lube oil in standard sump

        • Prelube pumps

        • Oil level regulator

      • Mounting System

        • Puck style low efficiency isolators

        • Spring type vibration isolators

        • IBC vibration isolators

      • Power Connections

        • Right side power connections

        • Ground cables between generator and terminal box

        • 2700 Frame, four lead, four terminal

        • Neutral ground connections

        • Rear power connections

        • Low voltage circuit breakers

        • Center post busbar

        • Left side power connections

      • Special Tests / Reports

        • PGS test report @ 0.8 power factor

        • PGS test report @ 1.0 power factor

        • Canadian Standards Association certification

        • Standard engine test charge

        • IBC certification

        • Generator set fuel consumption test

        • OSHPD certification

        • Generator test report

        • Torsional vibration analysis reports

        • Fuel consumption test

      • Starting and Charging

        • 10, 20, 35 and 50 amp battery chargers

        • 24 Volt battery set - Dry

        • Electric starting motors

        • Air starting motors

        • Starter cover

        • Engine barring device

        • Air pressure regulator

        • Jacket water heaters

      • Extended Service Coverage

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN