THIS IS MY SELECT

Diesel Generator Sets

3516 Diesel Generator Set

Standby Rating

93.0 hp

2000 kVA

Prime Power Rating

93.0 hp

1825 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel Consumption

THIS IS MY SELECT

backhoe loader

3516 Diesel Generator Set

Standby Rating

93.0 hp

2000 kVA

Prime Power Rating

93.0 hp

1825 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel Consumption

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Standby Rating

        93.0 in

        93.0 mm

        2000 kVA

        Prime Power Rating

        93.0 in

        93.0 mm

        1825 kVA

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Low Fuel Consumption

        Voltage

        93.0 in

        93.0 mm

        380 to 11000 Volts

        Frequency

        93.0 in

        93.0 mm

        50 Hz

        Speed

        93.0 in

        93.0 mm

        1500 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Mission Critical, Prime, Continuous

        Maximum Rating

        93.0 in

        93.0 mm

        2000 kVA

        Minimum Rating

        93.0 in

        93.0 mm

        1600 kVA

      • Engine Model

        93.0 in

        93.0 mm

        3516 TA, V-16, 4-Stroke Water-Cooled Diesel

        Bore

        6.69 in

        170 mm

        Stroke

        7.48 in

        190 mm

        Displacement

        4,210.64 in³

        69 l

        Compression Ratio

        93.0 in

        93.0 mm

        13.0:1

        Aspiration

        93.0 in

        93.0 mm

        TA

        Fuel System

        93.0 in

        93.0 mm

        Mechanical unit injection

        Governor Type

        93.0 in

        93.0 mm

        Woodward

      • Length - Maximum

        232.9 in

        5,919 mm

        Width - Maximum

        90 in

        2,286 mm

        Height - Maximum

        93.2 in

        2,367 mm

        Dry Weight - Genset (maximum)

        33,900 lb

        16,375 kg

      • Air Inlet System

      • Air Inlet

      • Cooling

      • Exhaust

      • Fuel

        • Secondary fuel filter

        • Fuel priming pump

        • Primary fuel filter with integral water separator

      • Generator

        • Matched to the performance and output characteristics of Cat engines

        • IP23 Protection

      • Power Termination

      • Control Panel

      • Control Panels

        • Over / Under voltage (27/59)

        • Serial annunciator module data link

        • Communications:

        • Overcurrent (50/51)

        • Over / Under frequency (81 o/u

        • Text alarm / event descriptions

        • Generator set packages include Caterpillar' s Voltage Regulator.

        • Programmable protective relaying functions:

        • 4 Programmable relay outputs (Form A)

        • Reverse Power (kW) (32)

        • Emergency stop

        • Amps (per phase & average)

        • Oil pressure (psi, kPa or bar)

        • Operating hours

        • 24 Volt DC operation

        • Low oil pressure

        • 6 Customer programmable digital inputs

        • 1 Programmable digital outputs

        • 1 Programmable relay outputs (Form C)

        • Volts (L-L & L-N)

        • Number of I/O varies on options selected:

        • RPM - DC volts

        • Low coolant level

        • kVAr-hr (total)

        • Controls: Speed adjust - Auto / start / stop control - Engine cool-down timer - Engine cycle crank - Alarm acknowledge - Lamp test - Load histogram feature - PLC functionality - Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy

        • kW-hr (total)

        • Failure to start (overcrank)

        • Environmental sealed front face

        • Power Factor (per phase & average)

        • Accessory module data link

        • Generator mounted - rear facing

        • High coolant temperature

        • Overspeed

        • 3 Analog inputs

        • Frequency (Hz)

        • Warning/shutdown with common LED indication of shutdowns for

        • Coolant temperature

        • IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min /max exciter. Limiter and exciter diode monitor

        • Customer data link (Modbus RTU)

        • kVA (per phase, average & percent)

        • Cat Connect

        • Generator phase sequence

        • Reverse Reactive Power (kVAr) (32RV

        • DC volts

        • kW (per phase, average & percent)

        • kVAr (per phase, average & percent)

        • Emergency stop pushbutton

        • Digital indication for

        • Low coolant temperature

        • EMCP 4.2B

      • Cooling System

        • ATAAC - 3516E Package Radiators shipped installed

        • Certified standard PGS provided

      • Exhaust System

        • Flanged faced outlet(s)

        • Dry exhaust manifold

      • Fuel System

        • Flexible fuel lines - shipped loose

        • Fuel priming pump

        • Fuel cooler; not included with packages without radiator

        • Secondary fuel filters

      • General

        • SAE Standard rotation

        • Flywheel and flywheel housing - SAE No. 00

        • Right hand servicing

        • Caterpillar yellow with high gloss black rails and radiator

      • Generator and Attachments

        • Medium Voltage:

        • Form wound

        • Winding temperature detectors

        • High Voltage:

        • 3 Phase brushless, salient pole

        • Permanent magnet

        • Permanent magnet

        • NEMA standard hole pattern

        • Internal Excitation

        • Six lead

        • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)

        • Low voltage:

        • Winding temperature detectors

        • NEMA standard hole pattern

        • Form wound

        • Winding temperature detectors

        • Random wound

        • Busbar connections, top center mounted, top cable entry

        • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)

        • Anti Condensation Space Heater

        • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)

      • Governing System

      • Literature

      • Lubrication System

        • Gear type lube oil pump

        • Fumes disposal

        • Oil drain lines and valve

        • Lubricating oil

        • Oil filter, filler and dipstick

        • Integral lube oil cool

      • Mounting System

        • Anti-vibration mounts (shipped loose)

        • Rubber anti-vibration mounts (shipped loose)

        • Rails - engine / generator / radiator mounting

      • Starting System

        • Battery disconnect switch

        • Battery and battery rack w/cables

        • 45 Amp charging alternator

        • 24 Volt electric starting motor

      • Air Inlet System

        • Dual element air cleaner

        • Single element filter

      • Exhaust

      • Cooling System

        • Optional installed radiators

        • Coolant

        • Standard ambient ATAAC radiators

        • Optional installed ATAAC radiators

        • Standard ambient radiators

        • Water level switch gauges

      • Generator

        • Internal excitation (IE)

        • Anti-condensation heater

        • Oversize and premium generators

        • Permanent magnet excitation (PMG)

      • Crankcase System

        • No explosion relief valves

        • Ventilation system

        • Explosion relief valves

      • Power Termination

        • Circuit breakers, UL listed

        • Circuit breakers, IEC compliant

      • Control Panels

        • Remote monitoring software

        • Generator temperature monitoring & protection

        • Load share module

        • Digital I/O module

        • EMCP 4.2B

      • Exhaust System

        • Exhaust offset

        • Tier 4 dosing cabinet

        • Flexible fittings

        • Mufflers

        • Tier 4 clean emissions module

        • Elbows

        • Flange and exhaust expanders

        • Tier 4 clean emission MOD Kits

        • Flanges

        • Clean emission parts

        • Y-Adapters

      • Mounting

        • Spring-type vibration isolator

        • IBC isolators

        • Rubber anti-vibration mounts

      • Fuel System

        • Fuel Priming Pumps (Tier 4) - Manual or electric

        • Primary fuel filter

      • Starting/Charging

        • Jacket water heater

        • Oversize batteries

        • Battery chargers

        • Air starting motor with control and silencer

        • Heavy-duty starting system

        • Charging alternator

      • General

        • Special paint (Colors other than Caterpillar yellow or high performance paints)

        • US aid emblem

      • Generators and Attachments

        • Thermostate for space heater

        • Alternator air cleaner

        • Differential current transformers (DCT)

        • Differntial current transformers (DCT) 8.7 kV and 15 kV classes

        • Generator conversion

        • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

        • Low / medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

        • Space heater

      • Instrumentation

      • Lubrication System

        • Oil level regulator

        • Prelube pumps

        • Lube oil in standard sump

      • Mounting System

        • Spring type vibration isolators

        • Puck style low efficiency isolators

        • IBC vibration isolators

      • Power Connections

        • Neutral ground connections

        • Center post busbar

        • Right side power connections

        • Rear power connections

        • 2700 Frame, four lead, four terminal

        • Left side power connections

        • Ground cables between generator and terminal box

        • Low voltage circuit breakers

      • Special Tests / Reports

        • IBC certification

        • Standard engine test charge

        • PGS test report @ 1.0 power factor

        • generator test report

        • Fuel consumption test

        • Canadian Standards Association certification

        • PGS test report @ 0.8 power factor

        • OSHPD certification

        • Torsional vibration analysis reports

        • Generator set fuel consumption test

      • Starting and Charging

        • Electric starting motors

        • Air pressure regulator

        • 24 Volt battery set - Dry

        • Engine barring device

        • Starter cover

        • Air starting motors

        • Jacket water heaters

        • 10, 20, 35 and 50 amp battery chargers

      • Extended Service Coverage

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN