THIS IS MY SELECT

Diesel Generator Sets

3516B (60 Hz) with Upgradeable Package

Standby Rating

93.0 hp

2250 ekW

Prime Power Rating

93.0 hp

1825 ekW

Emissions/Fuel Strategy

93.0 hp

Low fuel, Low Emissions

THIS IS MY SELECT

backhoe loader

3516B (60 Hz) with Upgradeable Package

Standby Rating

93.0 hp

2250 ekW

Prime Power Rating

93.0 hp

1825 ekW

Emissions/Fuel Strategy

93.0 hp

Low fuel, Low Emissions

Specifications

The3516B with the upgradeable packaging design has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance to matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.

      • Standby Rating

        93.0 in

        93.0 mm

        2250 ekW

        Prime Power Rating

        93.0 in

        93.0 mm

        1825 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Low fuel, Low Emissions

        Voltage

        93.0 in

        93.0 mm

        380 to 480 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Mission Critical, Prime, Continuous

        Maximum Rating

        93.0 in

        93.0 mm

        2250 ekW

        Minimum Rating

        93.0 in

        93.0 mm

        1640 ekW

      • Engine Model

        93.0 in

        93.0 mm

        3516B TA, V-16, 4-Stroke Water-Cooled Diesel

        Bore

        6.69 in

        170 mm

        Stroke

        7.48 in

        190 mm

        Displacement

        4,210.64 in

        69 l

        Compression Ratio

        93.0 in

        93.0 mm

        14.0:1

        Aspiration

        93.0 in

        93.0 mm

        TA

        Fuel System

        93.0 in

        93.0 mm

        MEUI

        Governor Type

        93.0 in

        93.0 mm

        ADEM™ A4

      • Length - Maximum

        234.5 in

        5,957 mm

        Width - Maximum

        90 in

        2,286 mm

        Height - Maximum

        98.2 in

        2,494 mm

        Dry Weight - Genset (maximum)

        30,310 lb

        13,750 kg

      • Air Inlet System

      • Control Panels

        • PLC functionality

        • Oil pressure (psi, kPa or bar)

        • Text alarm / event descriptions

        • KVAR/PF modes

        • Cat Connect

        • Overspeed

        • Amps (per phase & average)

        • Programmable protective relaying functions:

        • DC volts

        • EMCP 4.2B

        • Power Factor (per phase & average)

        • Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)

        • Load histogram feature

        • Generator set packages include:

        • Frequency (Hz)

        • Emergency stop pushbutton

        • Over / under voltage (27/59)

        • RFI suppression

        • 24 Volt DC operation

        • Low coolant level

        • Reverse power (kW) (32) - Reverse reactive power (kVAr) (32RV) - Overcurrent (50/51)

        • 4 Programmable relay outputs (Form A)

        • Volts (L-L & L-N)

        • Caterpillar' s voltage regulator

        • IVR includes:

        • Auto / start / stop control

        • kVA (per phase, average & percent)

        • Lamp test

        • Over / under frequency (81 o/u)

        • Environmental sealed front face

        • 3 Phase voltage sensing

        • Engine cool

        • kVAr-hr (total)

        • Low oil pressure

        • Accessory module data link

        • Emergency stop

        • Customer data link (Modbus RTU)

        • Communications:

        • Warning / shutdown with common LED indication of shutdowns for:

        • 0 True RMS AC metering, 3-phase, +/-2% accuracy

        • Digital indication for:

        • Customizable screens

        • Failure to start (overcrank)

        • Serial annunciator module data link

        • Coolant temperature

        • Controls:

        • Overcurrent (50/51)

        • Number of I/O varies on options selected:

        • Reactive droop capability

        • Low coolant temperature

        • High coolant temperature

        • Min / max exciter

        • Alarm acknowledge

        • RPM

        • Generator phase sequence

        • Limiter and exciter diode monitor

        • Speed adjust

        • Operating hours

        • kW (per phase, average & percent

        • 3 Analog inputs

        • Generator mounted - rear facing

        • 6 Customer programmable digital inputs

      • Lubrication System

        • Oil filter, filler and dipstick

        • Oil drain lines and valve

        • Gear type lube oil pump

        • Fumes disposal

        • Lubricating oil

      • Mounting System

        • Rubber anti-vibration mounts (shipped loose)

        • Rails - engine/generator/radiator mounting

        • Anti-vibration mounts (shipped loose)

      • Starting System

        • 45 Amp charging alternator

        • 24 Volt electric starting motor

        • Battery and battery rack w/cables

        • Battery disconnect switch

      • Literature

      • Control System

      • Air Inlet System

        • Dual element air cleaner

        • Single element filter

      • Cooling System

        • Water level switch gauges

        • Optional installed ATAAC radiators

        • Standard ambient ATAAC radiators

        • Standard ambient radiators

        • Coolant

        • Optional installed radiators

      • Crankcase System

        • Explosion relief valves

        • No explosion relief valves

        • Ventilation system

      • Exhaust System

        • Elbows

        • Flange and exhaust expanders

        • Tier 4 clean emissions module

        • Tier 4 clean emission MOD Kits

        • Clean emission parts

        • Exhaust offset

        • Mufflers

        • Tier 4 dosing cabinet

        • Flanges

        • Flexible fittings

        • Y-Adapters

      • Fuel System

        • Fuel Priming Pumps (Tier 4) - Manual or Electric

        • Primary Fuel Filter

      • General

        • US aid emblem

        • Special paint (Colors other than Caterpillar yellow or high performance paints)

      • Generators and Attachments

        • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

        • Generator conversion

        • Differential current transformers (DCT)

        • Differential current transformers (DCT) 8.7 kV and 15 kV classes

        • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

        • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

        • Thermostat for space heater

        • Space heater

        • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

        • Alternator air cleaner

        • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

        • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame

      • Instrumentation

      • Lubrication System

        • Oil level regulator

        • Prelube pumps

        • Lube oil in standard sump

      • Mounting System

        • Puck style low efficiency isolators

        • Spring type vibration isolators

        • IBC vibration isolators

      • Power Connections

        • Right side power connections

        • Ground cables between generator and terminal box

        • Neutral ground connections

        • Low voltage circuit breakers

        • 2700 Frame, four lead, four terminal

        • Rear power connections

        • Left side power connections

        • Center post busbar

      • Special Tests / Reports

        • PGS test report @ 0.8 power factor

        • PGS test report @ 1.0 power factor

        • Fuel consumption test

        • Canadian Standards Association certification

        • Torsional vibration analysis reports

        • IBC certification

        • generator test report

        • Generator set fuel consumption test

        • OSHPD certification

        • Standard engine test charge

      • Starting and Charging

        • Engine barring device

        • Air pressure regulator

        • Starter cover

        • Electric starting motors

        • Jacket water heaters

        • Air starting motors

        • 24 Volt battery set - Dry

        • 10, 20, 35 and 50 amp battery chargers

      • Extended Service Coverage

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN