THIS IS MY SELECT
Diesel Generator Sets
3516B Generator Set
Prime Power Rating
93.0 hp
1825 ekW
Continuous Rating
93.0 hp
1640 ekW
Emissions/Fuel Strategy
93.0 hp
Low Fuel Consumption
THIS IS MY SELECT
backhoe loader
3516B Generator Set
Prime Power Rating
93.0 hp
1825 ekW
Continuous Rating
93.0 hp
1640 ekW
Emissions/Fuel Strategy
93.0 hp
Low Fuel Consumption
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Prime Power Rating
93.0 in
93.0 mm
1825 ekW
Continuous Rating
93.0 in
93.0 mm
1640 ekW
Emissions/Fuel Strategy
93.0 in
93.0 mm
Low Fuel Consumption
Voltage
93.0 in
93.0 mm
380 to 13800 Volts
Frequency
93.0 in
93.0 mm
60 Hz
Speed
93.0 in
93.0 mm
1800 rpm
Duty Cycle
93.0 in
93.0 mm
Prime, Continuous
Maximum Rating
93.0 in
93.0 mm
1825 ekW
Minimum Rating
93.0 in
93.0 mm
1640 ekW
-
Engine Model
93.0 in
93.0 mm
3516B TA, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69 in
170 mm
Stroke
7.48 in
190 mm
Displacement
4,210.64 in
69 l
Compression Ratio
93.0 in
93.0 mm
14.0:1
Aspiration
93.0 in
93.0 mm
TA
Fuel System
93.0 in
93.0 mm
Electronic unit injection
Governor Type
93.0 in
93.0 mm
Adem™4
-
Length - Maximum
258.1 in
6,557 mm
Width - Maximum
90.1 in
2,288 mm
Height - Maximum
94.1 in
2,391 mm
Dry Weight - Genset (maximum)
33,300 lb
15,135 kg
-
Air Inlet System
-
Cooling
-
Exhaust
-
Fuel
-
Primary fuel filter with integral water separator
-
Secondary fuel filter
-
-
Control System
-
Generator set packages include Caterpillars Voltage
-
6 Customer programmable digital inputs
-
Controls:
-
Low coolant temperature
-
Auto/start/stop control
-
Low coolant level
-
Customer data link (Modbus RTU)
-
PLC functionality
-
kVA (per phase, average & percent)
-
Reverse Power (kW) (32)
-
Alarm acknowledge
-
kW (per phase, average & percent)
-
kW-hr (total)
-
Lamp test
-
RPM
-
Volts (L-L & L-N), frequency (Hz)
-
Generator phase sequence
-
Operating hours
-
kVAr-hr (total)
-
True RMS AC metering, 3-phase, +/-2% accuracy
-
Over / Under Frequency (81 o/u)
-
Accessory module data link
-
Number of I/O varies on options selected:
-
High coolant temperature
-
Overspeed
-
1 Programmable digital outputs
-
Regulator (IVR) - IVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter
-
DC volts
-
Reverse Reactive Power (kVAr) (32RV)
-
Amps (per phase & average)
-
Oil pressure (psi, kPa or bar)
-
Coolant temperature
-
Failure to start (overcrank)
-
3 Analog inputs
-
Power Factor (per phase & average)
-
EMCP 4.3
-
kVAr (per phase, average & percent)
-
Cat Connect
-
Engine cool-down timer
-
1 Programmable relay outputs (Form C)
-
Environmental sealed front face
-
Warning / shutdown with common LED indication of shutdowns for:
-
24 Volt DC operation
-
Over / Under voltage (27/59)
-
Emergency stop pushbutton
-
Limiter and exciter diode monitor
-
Generator mounted - rear facing
-
Digital indication for:
-
Text alarm / event descriptions
-
Customizable screens
-
Load histogram feature
-
Emergency stop
-
Serial annunciator module data link
-
Programmable protective relaying functions:
-
Low oil pressure
-
Communications:
-
Speed adjust
-
Engine cycle crank
-
4 Programmable relay outputs (Form A)
-
Overcurrent (50/51)
-
-
Power Termination
-
Control Panel
-
Cooling System
-
Exhaust System
-
Dry exhaust manifold
-
Flanged faced outlet(s)
-
-
Fuel System
-
Fuel cooler; not included with packages without radiator
-
Flexible fuel lines - shipped loose
-
Secondary fuel filters
-
Fuel priming pump
-
-
General
-
SAE Standard Rotation
-
Flywheel and Flywheel housing-SAE No. 00
-
Paint - Caterpillar yellow except rails and radiators gloss black
-
RH Service
-
-
Generators and Attachments
-
Matched to the performance and output characteristics of Cat engines
-
Random wound
-
IP23 Protection
-
Anti condensation space heater
-
3 Phase brushless, salient pole
-
HV:
-
Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
-
LV
-
NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby) - 60 Hz models: NEMA standard hole pattern
-
6 Lead
-
Form wound
-
Busbar connections, right side extension box, bottom cable entry - 60 Hz models: NEMA standard hole pattern
-
Winding temperature detectors
-
MV:
-
NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)
-
-
Governing System
-
Lube System
-
Oil drain lines and valve
-
Lubricating oil
-
Integral lube oil cooler
-
Oil filter, filler and dipstick
-
Fumes disposal
-
Gear type lube oil pump
-
-
Mounting System
-
Rails - engine / generator / radiator mounting.
-
Rubber anti-vibration mounts (shipped loose)
-
Anti-vibration mounts (shipped loose).
-
-
Starting System
-
Battery disconnect switch
-
24 Volt electric starting motor
-
45 Amp charging alternator
-
Battery and battery rack w/cables
-
-
Exhaust
-
Air Inlet System
-
Standard ambient radiators
-
Dual Element Air Cleaner
-
Standard ambient ATAAC radiators
-
Single Element Filter
-
Optional Radiator Arrangements
-
-
Generator
-
Anti-condensation heater
-
Permanent magnet excitation (PMG)
-
Oversize and premium generators
-
Internal excitation (IE)
-
-
Control Panels
-
EMCP 4.4
-
Load share module
-
Digital I/O module
-
Generator main terminal box
-
Remote monitoring software
-
Vandal proof panel cover
-
Generator temperature monitoring & protection
-
Empty upper box
-
Cable Shroud
-
Annunciator - local
-
Digital I/O module
-
Annunciator - remote
-
Side extension box
-
-
Cooling System
-
Coolant
-
Water level switch gauges
-
-
Crankcase Systems
-
No explosion relief valves
-
Explosion relief valve
-
Crankcase ventilation systems
-
Crankcase protection groups:
-
-
Mounting
-
Rubber anti-vibration mounts
-
IBC isolators
-
-
Exhaust System
-
Flange and exhaust expanders
-
Flexible fittings
-
Tier 4 lean emissions moduel
-
Flanges
-
Elean emission parts
-
Tier 4 dosing cabinet
-
Exhaust offset
-
Mufflers
-
Tier 4 clean emission MOD kits
-
Y Adapters
-
Elbows>
-
-
Starting/Charging
-
Oversize batteries
-
Charging alternator
-
Heavy-duty starting system
-
Jacket water heater
-
Battery chargers
-
-
General
-
CSA Certification
-
EEC Declaration of Conformity
-
Automatic transfer switches (ATS)
-
UL 2200 package
-
Integral & sub-base UL listed dual wall fuel tanks
-
EU Certificate of Conformance (CE)
-
Integral & sub-base fuel tanks
-
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
-
Enclosures: sound attenuated, weather protective
-
The following options are based on regional and product configuration:
-
-
Extended Service Coverage
-
Fuel System
-
Primary fuel filter
-
Fuel priming pump (Tier 4)
-
Gas fuel filter
-
-
Generators and Attachments
-
Generator conversions
-
Hi volt optional attachments
-
2700 Frame - 6300, 6600, 6900 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
-
1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, PM, No. of leads = 6, Pitch = .6667
-
Generators high voltage
-
Differential current transformers
-
1600 Frame - 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM ,FW, PM, No. of leads = 6, Pitch = .6667
-
1600 Frame - 380, 440, 480, 600 Volts, 3 Phase 1800 RPM, RW, IE, No. of leads = 6, Pitch = .6667
-
Alternator air cleaner
-
1800 Frame
-
Space heater kit
-
3000 Frame - 12470, 13200, 13800 Volts, 3 Phase 1800 RPM, FW, PM, No. of leads = 6, Pitch = .6667
-
-
Instrumentation
-
Lube System
-
Oil level regulator
-
Prelube pump groups
-
Lube oil in standard sump
-
-
Mounting System
-
IBC vibration isolators
-
Puck style low efficiency isolators
-
Spring type vibration isolators
-
-
Power Connections
-
Center post busbar
-
Cable entry - rear
-
Rear power connections
-
Cable entry - right side
-
Cable entry - left side
-
Grounding groups
-
Neutral ground connections
-
Right side power connections
-
left side power connections
-
-
Power Termination
-
Circuit breakers - LV Packages
-
2000, 2500, 3200 Amp, 4 Pole, IEC rated circuit breakers
-
Circuit breakers, IEC compliant
-
Circuit breakers, UL listed
-
1600, 2000, 2500, 3000 and 4000 Amp, 3 Pole, UL-100% rated circuit breakers
-
2000, 2500, 3200 Amp, 3 Pole, IEC rated circuit breakers
-
-
Special Tests / Reports
-
Generator set report
-
PGS test report @ 0.8 power factor
-
Fuel consumption test
-
Torsional vibration analysis
-
Seismic certifications
-
PGS test report @ 1.0 power factor
-
Standard engine test
-
OSPD certification
-
-
Starting / Charging
-
10, 20, 35 Amp battery chargers
-
Engine barring devices
-
Batteries, racks and cables
-
Jacket water heaters
-
Air starting motors with control and silencer
-
Electric starting motors
-
Starter covers
-
50 Amp NFPA battery charger
-
Air pressure regulator
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance