THIS IS MY SELECT

Diesel Generator Sets

3516C (50 Hz) with Upgradeable Package

Standby Rating

93.0 hp

2750 kVA

Prime Power Rating

93.0 hp

2500 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel Consumption

THIS IS MY SELECT

backhoe loader

3516C (50 Hz) with Upgradeable Package

Standby Rating

93.0 hp

2750 kVA

Prime Power Rating

93.0 hp

2500 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel Consumption

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Standby Rating

        93.0 in

        93.0 mm

        2750 kVA

        Prime Power Rating

        93.0 in

        93.0 mm

        2500 kVA

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Low Fuel Consumption

        Voltage

        93.0 in

        93.0 mm

        380 to 11000 volts

        Frequency

        93.0 in

        93.0 mm

        50 Hz

        Speed

        93.0 in

        93.0 mm

        1500 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Mission Critical, Prime

        Maximum Rating

        93.0 in

        93.0 mm

        2750 kVA

        Minimum Rating

        93.0 in

        93.0 mm

        2500 kVA

      • Engine Model

        93.0 in

        93.0 mm

        3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel

        Bore

        6.69 in

        170 mm

        Stroke

        8.46 in

        215 mm

        Displacement

        4,765 in

        78 l

        Compression Ratio

        93.0 in

        93.0 mm

        14:01

        Aspiration

        93.0 in

        93.0 mm

        TA

        Fuel System

        93.0 in

        93.0 mm

        Electronic unit injection

        Governor Type

        93.0 in

        93.0 mm

        Adem™3

      • Length - Maximum

        228.3 in

        5,800 mm

        Width - Maximum

        75.9 in

        1,929 mm

        Height - Maximum

        80.7 in

        2,050 mm

        Dry Weight - Genset (maximum)

        32,404 lb

        14,698 kg

      • Air Inlet System

        • Air cleaner

        • Single element canister type with service indicator

      • Control Panel

        • RPM

        • Engine cycle crank

        • Failure to start (overcrank)

        • Warning/shutdown with common LED indication of shutdowns for:

        • Speed adjust

        • True RMS AC metering, 3-phase, +/-2% accuracy

        • Accessory module data link

        • Overcurrent (50/51)

        • DC volts

        • Controls:

        • Generator phase sequence

        • Low oil pressure

        • 2 Programmable digital outputs

        • Reverse power (kW) (32)

        • Low coolant level

        • Operating hours

        • Frequency (Hz)

        • kVAr-hr (total)

        • kVA (per phase, average & percent)

        • Lamp test

        • Over / under frequency (81 o/u)

        • 6 programmable digital inputs

        • 2 Programmable relay outputs (Form C)

        • 24 Volt DC operation

        • Customer data link (Modbus RTU)

        • EMCP 4 Genset Controller

        • Volts (L-L & L-N)

        • High coolant temperature

        • Alarm acknowledge

        • Oil pressure (psi, kPa or bar)

        • 4 Programmable relay outputs (Form A)

        • Overspeed

        • EMCP4.2B controller includes:

        • Engine cool-down timer

        • Panel lights

        • kW (per phase, average & percent)

        • Low coolant temperature

        • Over / under voltage (27/59)

        • Serial annunciator module data link

        • Generator mounted - rear facing

        • Communications:

        • kVAr (per phase, average & percent)

        • Digital indication for:

        • Text alarm / event descriptions

        • EMCP 4.2B

        • Coolant temperature

        • Emergency stop pushbutton

        • Programmable protective relaying functions:

        • kW-hr (total)

        • Reverse reactive power (kVAr) (32RV)

        • Amps (per phase & average)

        • Environmental sealed front face

        • Power Factor (per phase & average)

      • Exhaust

      • Fuel

      • Generator

        • IP23 Protection

        • Matched to the performance and output characteristics of Cat engines

      • Power Termination

      • Starting/Charging

        • Heavy duty starting system

        • Charging alternator

      • Cooling System

        • Fan and belt guards

        • Coolant drain line with valve

        • JWAC

        • Caterpillar Extended Life Coolant

        • Coolant level sensors

        • Radiator fan and fan drive

      • Cooling

      • Exhaust System

        • Flanged faced outlet(s)

        • Dry exhaust manifold

      • Fuel System

        • Flexible fuel lines - shipped loose

        • Fuel priming pump

        • Fuel cooler; not included with packages without radiator

        • Secondary fuel filters

      • Generators and Attachments

        • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby).

        • Busbar connections, top center mounted, top cable entry

        • Random wound

        • 6 Lead

        • Winding temperature detectors

        • IEC standard hole pattern

        • Internal excitation

        • 3 phase brushless, salient pole

        • Generator set packages include Caterpillar's Digital Voltage Regulator (CDVR). CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter

      • Governing System

      • Literature

      • Lube System

        • Gear type lube oil pump

        • Integral lube oil cooler

        • Fumes disposal

        • Lubricating oil

        • Oil filter, filler and dipstick

        • Oil drain lines and valve

      • Mounting System

        • Rails - engine / generator / radiator mounting

        • Rubber anti-vibration mounts (shipped loose)

      • Starting / Charging System

        • 24 Volt electric starting motor

        • Battery and battery rack w/cables

        • Battery disconnect switch

      • General

        • Right hand servicing

        • Flywheel and flywheel housing-SAE No. 00

        • Paint: Caterpillar yellow with high gloss black rails & radiator

        • SAE standard rotation

      • Air Inlet System

        • Remote air inlet adapters

        • Dual element air cleaners

        • Air inlet protection

        • Heavy duty air cleaners

      • Circuit Breakers

        • Cable entry options

        • Control packaging for enclosures

        • Trip Units

        • Load take off; IEC standard hole

        • Busbar power connections

        • Center posts busbars

        • EMAX breakers

      • Power Termination

      • Control Panels

        • Annunciator modules

        • Generator temperature monitoring

        • Auxiliary box

        • Remote speed adjust

        • Busbar connections

        • Vandal proof panel door

        • Voltage raise / lower switch

        • EMCP 4.3, EMCP 4.4

        • Local and remote monitoring

        • Language options

        • Customer interface options

        • External box clips

        • EMAX breaker connections

        • Governors

      • Cooling System

        • Heat exchangers

        • Water level switch gauges

        • Radiator duct flanges

        • Optional Serpentine radiators

      • European Certifications

      • Exhaust System

        • Through wall installation kit

        • Muffler mounting kits

        • Mufflers

        • Flexible fittings

      • Fuel System

        • Fuel coolers

        • Primary fuel filter

      • Generators and attachments

        • Generators

        • 3 Phase, Random wound, Internal excitation

        • Internal excitation

        • 3 Phase, 380 / 400 / 415 / 3300 / 6600 / 10000 / 10500 / 11000 volt

        • Number of leads: 6

        • Pitch: 0.6667

      • Instrumentation

        • Pyrometers and thermocouples

        • Thermocouples

      • Lube System

        • Oil level regulator

        • Electric prelube pumps

        • Manual prelube sump pumps

      • Mounting System

        • IBC vibration isolators

        • Spring type vibration isolators

      • Protection System

      • Special Tests / Reports

        • IBC seismic certificate

        • CSA test and certification

        • PGS test report @ 1.0 power factor

        • Neutral ground certificate

        • PGS test report @ 0.8 power factor

      • Starting / Charging System

        • 10 and 20 amp battery chargers

        • Charging alternators - 50 Amp

        • Dual 24 volt electric starting motors

        • ETHER starting aids

        • 24 Volt battery sets - Dry

        • Jacket water heaters

      • General

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN