Standby Rating

93.0 hp

2500/2000 ekW

Prime Power Rating

93.0 hp

2250/1825 ekW

Emissions/Fuel Strategy

93.0 hp

U.S. EPA Cert., Tier 2

THIS IS MY SELECT

backhoe loader

3516C Generator Set

Standby Rating

93.0 hp

2500/2000 ekW

Prime Power Rating

93.0 hp

2250/1825 ekW

Emissions/Fuel Strategy

93.0 hp

U.S. EPA Cert., Tier 2

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Standby Rating

        93.0 in

        93.0 mm

        2500/2000 ekW

        Prime Power Rating

        93.0 in

        93.0 mm

        2250/1825 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        U.S. EPA Cert., Tier 2

        Voltage

        93.0 in

        93.0 mm

        380 to 13800 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Mission Critical, Prime, Continuous

        Maximum Rating

        93.0 in

        93.0 mm

        2500 ekW

        Minimum Rating

        93.0 in

        93.0 mm

        1650 ekW

      • Engine Model

        93.0 in

        93.0 mm

        3516C, ATAAC, V-16,4-Stroke Water-Cooled Diesel

        Bore

        6.69 in

        170 mm

        Stroke

        7.48 in

        190 mm

        Stroke - HD

        8.46 in

        215 mm

        Displacement

        4,764.73 in

        78 l

        Compression Ratio

        93.0 in

        93.0 mm

        14.7:1

        Aspiration

        93.0 in

        93.0 mm

        TA

        Fuel System

        93.0 in

        93.0 mm

        Electronic unit injection

        Governor Type

        93.0 in

        93.0 mm

        Adem™3

      • Length - Minimum

        284.6 in

        7,229 mm

        Length - Maximum

        295.1 in

        7,495 mm

        Width - Minimum

        93.7 in

        2,379 mm

        Width - Maximum

        101.2 in

        2,569 mm

        Height - Minimum

        116.5 in

        2,958 mm

        Height - Maximum

        118.5 in

        3,009 mm

        Dry Weight - Genset (minimum)

        35,880 lb

        16,275 kg

        Dry Weight - Genset (maximum)

        38,780 lb

        17,590 kg

      • Air Inlet System

      • Cooling

      • Exhaust

      • Control Panels

        • Communications:

        • Reverse reactive power (kVAr) (32RV)

        • Customer data link (Modbus RTU)

        • Generator mounted - rear facing

        • 1 Programmable digital outputs

        • Auto / start / stop control -

        • Serial annunciator module data link

        • Engine cool-down timer

        • 24 Volt DC operation

        • Controls:

        • Generator set packages include Caterpillar' s Voltage Regulator. IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min / max exciter. Limiter and exciter diode monitor

        • Alarm acknowledge

        • Cat connect

        • Engine cycle crank

        • Text alarm / event descriptions

        • Overcurrent (50 / 51)

        • Accessory module data link

        • EMCP 4.2B

        • 1 Programmable relay outputs (Form C)

        • Emergency stop pushbutton

        • Speed adjust -

        • 4 Programmable relay outputs (Form A)

        • Number of I/O varies on options selected:

        • 6 Customer programmable digital inputs

        • Environmental sealed front face

        • Load histogram feature

        • Lamp test

        • PLC functionality

        • Customizable screens -0 True RMS AC metering, 3-phase, +/-2% accuracy

        • Digital indication for:

        • Operating hours

        • RPM

        • DC volts

        • Frequency (Hz)

        • Coolant temperature

        • Volts (L-L & L-N)

        • Oil pressure (psi, kPa or bar)

        • Amps (per phase & average)

        • kVAr (per phase, average & percent

        • kVA (per phase, average & percent)

        • kW (per phase, average & percent)

        • Power Factor (per phase & average)

        • kW-hr (total)

        • kVAr-hr (total)

        • High coolant temperature

        • Overspeed

        • Failure to start (overcrank)

        • Warning / shutdown with common LED indication of shutdowns for:

        • Emergency stop

        • Low oil pressure

        • Low coolant level -

        • Low coolant temperature

        • Programmable protective relaying functions:

        • Over / under Frequency (81 o/u)

        • Generator phase sequence

        • Over / under voltage (27 / 59)

        • Reverse power (kW) (32)

      • Fuel

      • Generator

        • Matched to the performance and output characteristics of Cat engines

        • IP23 Protection

      • Power Termination

      • Control Panel

      • Cooling System

        • Certified standard PGS provided

        • ATAAC - 3516E Package Radiators shipped installed

      • Exhaust System

        • Flanged faced outlet(s)

        • Dry exhaust manifold

      • Fuel System

        • Flexible fuel lines - shipped loose

        • Fuel cooler; not included with packages without radiator

        • Secondary fuel filters

        • Fuel priming pump

      • General

        • Caterpillar yellow with high gloss black rails and radiator

        • Right hand servicing

        • Flywheel and flywheel housing - SAE No. 00

        • Paint - Caterpillar Yellow except rails and radiators gloss black

        • SAE Standard rotation

      • Generator and Attachments

        • Busbar connections, top center mounted, top cable entry

        • Class H temperature rise at 40C ambient (125C prime / 150C standby)

        • Low Voltage:

        • NEMA standard hole pattern

        • Medium Voltage:

        • Anti condensation space heater

        • 6 Lead

        • Random wound

        • Form wound

        • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime / 150C standby)

        • Permanent magnet

        • Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)

        • Internal excitation

        • 3 Phase brushless, salient pole

        • High voltage:

        • Winding temperature detectors

        • Busbar connections, right side extension box, bottom cable entry

      • Governing System

      • Literature

      • Lubrication System

        • Lubricating oil

        • Fumes disposal

        • Integral lube oil cool

        • Oil drain lines and valve

        • Oil filter, filler and dipstick

        • Gear type lube oil pump

      • Mounting System

        • Anti-vibration mounts (shipped loose)

        • Rubber anti-vibration mounts (shipped loose)

        • Rails - engine/generator/radiator mounting

      • Starting System

        • Battery disconnect switch

        • 45 Amp charging alternator

        • 24 Volt electric starting motor

        • Battery and battery rack w/cables

      • Control System

      • Exhaust

      • Air Inlet System

        • Single element filter

        • Dual element air cleaner

      • Generator

        • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)

        • Oversize and premium generators

        • Anti-condensation heater

      • Cooling System

        • Coolant

        • Standard ambient ATAAC radiators

        • Optional installed radiators

        • Optional installed ATAAC radiators

        • Standard ambient radiators

        • Water level switch gauges

      • Power Termination

        • Circuit breakers, UL listed

        • Circuit breakers, IEC compliant

      • Crankcase System

        • Explosion relief valves

        • Ventilation system

        • No explosion relief valves

      • Control Panels

        • Load share module

        • Digital I/O module

        • Generator temperature monitoring & protection

        • Remote monitoring software

      • Mounting

        • Rubber anti-vibration mounts

        • IBC isolators

      • Exhaust System

        • Y-Adapters

        • Flexible fittings

        • Exhaust offset

        • Tier 4 clean emissions module

        • Elbows

        • Flange and exhaust expanders

        • Tier 4 clean emission MOD Kits

        • Tier 4 dosing cabinet

        • Flanges

        • Mufflers

        • Clean emission parts

      • Starting/Charging

        • Oversize batteries

        • Battery chargers

        • Charging alternator

        • Air starting motor with control and silencer

        • Heavy-duty starting system

      • Fuel System

      • General

        • The following options are based on regional and product configuration:

        • UL 2200 package

        • CSA Certification

        • EEC Declaration of Conformity

        • Special paint (Colors other than Caterpillar yellow or high performance paints)

        • Integral & sub-base fuel tanks

        • US aid emblem

        • Enclosures: sound attenuated, weather protective

        • Automatic transfer switches (ATS)

        • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

        • EU Certificate of Conformance (CE)

        • Integral & sub-base UL listed dual wall fuel tanks

      • Generators and Attachments

        • High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

        • High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame

        • Thermostate for space heater

        • Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

        • Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame

        • Differential current transformers (DCT) 8.7 kV and 15 kV classes

        • Generator conversion

        • Space heater kits

        • Alternator air cleaner

      • Instrumentation

      • Lubrication System

        • Oil level regulator

        • Lube oil in standard sump

        • Prelube pumps

      • Mounting System

        • Puck style low efficiency isolators

        • Spring type vibration isolators

        • IBC vibration isolators

      • Power Connections

        • Ground cables between generator and terminal box

        • Neutral ground connections

        • Left side power connections

        • Center post busbar

        • Right side power connections

        • 2700 Frame, four lead, four terminal

        • Rear power connections

        • Low voltage circuit breakers

      • Special Tests / Reports

        • IBC certification

        • Fuel consumption test

        • Generator test report

        • PGS test report @ 1.0 power factor

        • Torsional vibration analysis reports

        • OSHPD certification

        • Generator set fuel consumption test

        • PGS test report @ 0.8 power factor

        • Standard engine test charge

        • Canadian Standards Association certification

      • Starting and Charging

        • Air pressure regulator

        • Starter cover

        • Air starting motors

        • 10, 20, 35 and 50 amp battery chargers

        • Electric starting motors

        • Jacket water heaters

        • 24 Volt battery set - Dry

        • Engine barring device

      • Extended Service Coverage

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN