THIS IS MY SELECT
Diesel Generator Sets
3516C Tier 4 Final
Standby Rating
93.0 hp
2500/2000 ekW
Prime Power Rating
93.0 hp
1825/2250 ekW
Emissions/Fuel Strategy
93.0 hp
U.S. EPA Certified
THIS IS MY SELECT
backhoe loader
3516C Tier 4 Final
Standby Rating
93.0 hp
2500/2000 ekW
Prime Power Rating
93.0 hp
1825/2250 ekW
Emissions/Fuel Strategy
93.0 hp
U.S. EPA Certified
Specifications
The 3516C HD generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The engines are certified to the US EPA Tier 4 Final emissions levels. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.
-
Standby Rating
93.0 in
93.0 mm
2500/2000 ekW
Prime Power Rating
93.0 in
93.0 mm
1825/2250 ekW
Emissions/Fuel Strategy
93.0 in
93.0 mm
U.S. EPA Certified
Voltage
93.0 in
93.0 mm
480 to 13800 Volts
Frequency
93.0 in
93.0 mm
60 Hz
Speed
93.0 in
93.0 mm
1800 rpm
Duty Cycle
93.0 in
93.0 mm
Standby, Mission Critical, Prime
Maximum Rating
93.0 in
93.0 mm
2500 ekW
Minimum Rating
93.0 in
93.0 mm
1825 ekW
-
Engine Model
93.0 in
93.0 mm
3516C HD, ATAAC, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.69 in
170 mm
Stroke
8.46 in
215 mm
Displacement
78 in
4,764.73 l
Compression Ratio
93.0 in
93.0 mm
14.7:1
Aspiration
93.0 in
93.0 mm
TA
Fuel System
93.0 in
93.0 mm
Electronic unit injection
Governor Type
93.0 in
93.0 mm
ADEM™A4
-
Length - Minimum
267.6 in
6,796.6 mm
Length - Maximum
277 in
7,037.5 mm
Width - Minimum
93.7 in
2,378.7 mm
Width - Maximum
101.2 in
2,569 mm
Height - Minimum
116.7 in
2,964.8 mm
Height - Maximum
118.9 in
3,019 mm
Dry Weight - Genset (minimum)
37,200 lb
16,874 kg
Dry Weight - Genset (maximum)
40,280 lb
18,270 kg
-
Air Inlet System
-
Cooling
-
Exhaust
-
Control Panels
-
Generator phase sequence
-
1 Programmable digital outputs
-
KAR / PF modes
-
Low coolant temperature
-
PLC functionality
-
Generator mounted - Rear facing
-
Environmental sealed front face
-
Generator set packages include:
-
Auto / start / stop control
-
Customer data link (Modbus RTU)
-
High coolant temperature
-
Warning/shutdown with common LED indication of shutdowns for:
-
0 True RMS AC metering, 3-phase, +/-2% accuracy
-
Low coolant level
-
Operating hours
-
kVAr (per phase, average & percent)
-
RFI suppression
-
Emergency stop
-
Digital indication for:
-
Amps (per phase & average)
-
Min / max exciter
-
Number of I/O varies on options selected:
-
Load histogram feature
-
Frequency (Hz)
-
Overcurrent (50/51)
-
Oil pressure (psi, kPa or bar)
-
Lamp test
-
Engine cool-down timer
-
Cat Connect
-
kW-hr (total) - kVAr-hr (total)
-
Limiter and exciter diode monitor
-
Communications:
-
Over / Under frequency (81 o/u)
-
6 Customer programmable digital inputs
-
Controls:
-
Overspeed
-
IVR includes reactive droop capability
-
Low oil pressure
-
RPM
-
24 Volt DC operation
-
Volts (L-L & L-N)
-
Text alarm / event descriptions
-
1 Programmable relay outputs (Form C)
-
Controls: Speed adjust
-
Reverse reactive power (kVAr) (32RV)
-
Power Factor (per phase & average)
-
High coolant temperature
-
Accessory module data link
-
Customizable screens
-
4 programmable relay outputs (Form A)
-
Caterpillar' s Voltage Regulator
-
Programmable protective relaying functions
-
Alarm acknowledge
-
Over / under voltage (27/59)
-
DC volts
-
kVA (per phase, average & percent)
-
Failure to start (overcrank)
-
Engine cycle crank
-
3 Phase voltage sensing
-
Coolant temperature
-
Serial annunciator module data link
-
Emergency stop pushbutton
-
Reverse power (kW) (32)
-
kW (per phase, average & percent)
-
3 Analog inputs
-
-
Fuel
-
Generator
-
Matched to the performance and output characteristics of Cat engines
-
IP23 Protection
-
-
Power Termination
-
Control Panel
-
Cooling System
-
Certified standard PGS provided
-
ATAAC - 3516E Package Radiators shipped installed
-
-
Exhaust System
-
Flanged faced outlet(s)
-
Dry exhaust manifold
-
-
Fuel System
-
Fuel cooler; not included with packages without radiator
-
Secondary fuel filters
-
Fuel priming pump
-
Flexible fuel lines - shipped loose
-
-
General
-
Right hand servicing
-
Caterpillar yellow with high gloss black rails and radiator
-
Paint - Caterpillar Yellow except rails and radiators gloss black
-
Flywheel and flywheel housing - SAE No. 00
-
SAE Standard rotation
-
-
Generator and Attachments
-
Form wound
-
High Voltage:
-
NEMA standard hole pattern
-
Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
-
Low Voltage: Random wound - Internal Excitation - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern
-
Permanent magne
-
Medium Voltage:
-
6 lead
-
3 Phase brushless, salient pole
-
Busbar connections, right side extension box, bottom cable entry
-
NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)
-
Permanent magnet
-
Anti condensation space heater
-
Winding temperature detectors
-
-
Governing System
-
Literature
-
Lubrication System
-
Integral lube oil cool
-
Oil drain lines and valve
-
Gear type lube oil pump
-
Fumes disposal
-
Lubricating oil
-
Oil filter, filler and dipstick
-
-
Mounting System
-
Rails - engine/generator/radiator mounting
-
Anti-vibration mounts (shipped loose)
-
Rubber anti-vibration mounts (shipped loose)
-
-
Starting System
-
Battery and battery rack w/cables
-
45 Amp charging alternator
-
24 Volt electric starting motor
-
Battery disconnect switch
-
-
Control System
-
Air Inlet System
-
Single element filter
-
Dual element air cleaner
-
-
Exhaust
-
Generator
-
Internal excitation (IE)
-
Anti-condensation heater
-
Oversize and premium generators
-
Permanent magnet excitation (PMG)
-
-
Cooling System
-
Coolant
-
Water level switch gauges
-
Standard ambient radiators
-
Optional installed ATAAC radiators
-
Optional installed radiators
-
Standard ambient ATAAC radiators
-
-
Power Termination
-
Circuit breakers, UL listed
-
Circuit breakers, IEC compliant
-
-
Crankcase System
-
No explosion relief valves
-
Explosion relief valves
-
Ventilation system
-
-
Control Panels
-
Remote monitoring software
-
Digital I/O module
-
Generator temperature monitoring & protection
-
Load share module
-
-
Exhaust System
-
Tier 4 clean emissions module
-
Flexible fittings
-
Flanges
-
Tier 4 clean emission MOD Kits
-
Mufflers
-
Tier 4 dosing cabinet
-
Flange and exhaust expanders
-
Clean emission parts
-
Exhaust offset
-
Y-Adapters
-
Elbows
-
-
Mounting
-
Starting/Charging
-
Battery chargers
-
Heavy-duty starting system
-
Charging alternator
-
Air starting motor with control and silencer
-
Oversize batteries
-
-
Fuel System
-
Primary Fuel Filter
-
Fuel Priming Pumps (Tier 4) - Manual or Electric
-
-
General
-
Automatic transfer switches (ATS)
-
The following options are based on regional and product configuration:
-
EEC Declaration of Conformity
-
Enclosures: sound attenuated, weather protective
-
UL 2200 package
-
US aid emblem
-
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
-
EU Certificate of Conformance (CE)
-
Integral & sub-base UL listed dual wall fuel tanks
-
CSA Certification
-
Special paint (Colors other than Caterpillar yellow or high performance paints)
-
Integral & sub-base fuel tanks
-
-
Generators and Attachments
-
Low / Medium voltage: 380, 416, 440, 480, 600, 2400, 4160 Volts, 3 Phase 1800 RPM, FW, PM, No. of Leads = 6, Pitch = .6667: 1600, 1800 Frame
-
Generator conversion
-
Thermostate for space heater
-
Alternator air cleaner
-
Differential current transformers (DCT) 8.7 kV and 15 kV classes
-
Space heater kits
-
High voltage: 6300, 6600, 6900 volts, 3 phase 1800 rpm, FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
-
High voltage: 12470, 13200, 13800 volts, 3 phase 1800 rpm,FW, PM, No. of Leads = 6, Pitch = .6667: 2700, 3000 Frame
-
Low / Medium voltage: 380, 440, 480, 600 volts, 3 phase 1800 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame
-
-
Instrumentation
-
Lubrication System
-
Lube oil in standard sump
-
Prelube pumps
-
Oil level regulator
-
-
Mounting System
-
IBC vibration isolators
-
Spring type vibration isolators
-
Puck style low efficiency isolators
-
-
Power Connections
-
Ground cables between generator and terminal box
-
Right side power connections
-
2700 Frame, four lead, four terminal
-
Neutral ground connections
-
Center post busbar
-
Rear power connections
-
Left side power connections
-
Low voltage circuit breakers
-
-
Special Tests / Reports
-
PGS test report @ 1.0 power factor
-
IBC certification
-
Canadian Standards Association certification
-
PGS test report @ 0.8 power factor
-
Generator set fuel consumption test
-
generator test report
-
Torsional vibration analysis reports
-
Standard engine test charge
-
OSHPD certification
-
Fuel consumption test
-
-
Starting and Charging
-
Jacket water heaters
-
Electric starting motors
-
Air starting motors
-
10, 20, 35 and 50 amp battery chargers
-
Air pressure regulator
-
24 Volt battery set - Dry
-
Engine barring device
-
Starter cover
-
-
Extended Service Coverage
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance