THIS IS MY SELECT

Diesel Generator Sets

3516E Generator Set

Maximum Rating

93.0 hp

3500 kVA

Minimum Rating

93.0 hp

3000 kVA

Emissions/Fuel Strategy

93.0 hp

Tier 2 Equivalent - 1808 rpm

THIS IS MY SELECT

backhoe loader

3516E Generator Set

Maximum Rating

93.0 hp

3500 kVA

Minimum Rating

93.0 hp

3000 kVA

Emissions/Fuel Strategy

93.0 hp

Tier 2 Equivalent - 1808 rpm

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Maximum Rating

        93.0 in

        93.0 mm

        3500 kVA

        Minimum Rating

        93.0 in

        93.0 mm

        3000 kVA

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Tier 2 Equivalent - 1808 rpm

        Voltage

        93.0 in

        93.0 mm

        380 to 11000 volts

        Frequency

        93.0 in

        93.0 mm

        50 Hz

        Speed

        93.0 in

        93.0 mm

        1808 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Mission Critical

      • Engine Model

        93.0 in

        93.0 mm

        3516E, V-16, 4-Stroke Water-Cooled Diesel

        Bore

        6.69 in

        170 mm

        Stroke

        8.46 in

        215 mm

        Displacement

        4,765 in³

        78.1 l

        Compression Ratio

        93.0 in

        93.0 mm

        14.7:1

        Aspiration

        93.0 in

        93.0 mm

        ATAAC

        Fuel System

        93.0 in

        93.0 mm

        Electronic Unit Injection

        Governor Type

        93.0 in

        93.0 mm

        Adem™5

      • Length - Minimum

        353.3 in

        8,973 mm

        Length - Maximum

        363.1 in

        9,224 mm

        Width - Minimum

        104 in

        2,460 mm

        Width - Maximum

        104 in

        2,460 mm

        Height - Minimum

        132.6 in

        3,342 mm

        Height - Maximum

        131.6 in

        3,342 mm

        Dry Weight - Genset (minimum)

        47,620 lb

        21,600 kg

        Dry Weight - Genset (maximum)

        52,911 lb

        24,000 kg

      • Air Inlet System

      • Control System

        • Text alarm / event descriptions

        • Emergency stop pushbutton

        • IVR includes reactive droop capability

        • KVAR / PF modes

        • EMCP 4.2B

        • 3 Phase voltage sensing

        • Generator mounted - rear facing

        • Generator set packages include:

        • 24 Volt DC operation

        • Caterpillar's Voltage Regulato

        • RFI suppression

        • Environmental sealed front face

        • Limiter and exciter diode monitor

        • Min / max exciter

        • Controls:

        • Speed adjust

        • Alarm acknowledge

        • Auto / start / stop control

        • Engine cycle crank

        • Engine cool

        • Customizable screens

        • PLC functionality

        • Lamp test

        • Load histogram feature

        • Accessory module data link

        • Reverse power (kW) (32)

        • 6 Customer programmable digital inputs

        • 3 Phase

        • +/- 2% accuracy

        • High coolant temperature

        • 0 True RMS AC metering

        • Programmable protective relaying functions:

        • Reverse reactive power (kVAr) (32RV)

        • Communications:

        • Generator phase sequence

        • Over / under voltage (27/59)

        • Overcurrent (50/51)

        • RPM

        • Number of I/O varies on options selected:

        • Overspeed

        • Serial annunciator module data link

        • Low coolant temperature

        • 4 Programmable relay outputs (Form A)

        • 1 Programmable relay outputs (Form C)

        • 3 Analog inputs

        • Over / under frequency (81 o/u)

        • Digital indication for:

        • Low coolant leve

        • Failure to start (overcrank)

        • Cat Connect

        • 1 Programmable digital outputs

        • DC volts

        • Operating hours

        • Coolant temperature

        • Oil pressure (psi, kPa or bar)

        • Amps (per phase & average)

        • Power Factor (per phase & average

        • Frequency (Hz)

        • Volts (L-L & L-N)

        • kW (per phase, average & percent)

        • kVA (per phase, average & percent

        • kVAr (per phase, average & percent)

        • Warning/shutdown with common LED indication of shutdowns for: Low oil pressure - High coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level -

        • Low oil pressure

        • kW-hr (total)

        • kVAr-hr (total)

      • Cooling System

        • ATAAC - 3516E Package radiators shipped installed

        • Certified standard PGS provided

      • Exhaust System

        • Flanged faced outlet(s)

        • Dry exhaust manifold

      • Fuel System

        • Secondary fuel filters

        • Fuel cooler; not included with packages without radiator

        • Flexible fuel lines - shipped loose

      • General

        • Right hand servicing

        • Caterpillar yellow with high gloss black rails and radiator

        • SAE Standard rotation

        • Flywheel and flywheel housing - SAE No. 00

      • Generator and Attachments

        • NEMA standard hole pattern

        • Medium Voltage:

        • Anti condensation space heater

        • NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby)

        • Winding temperature detectors

        • High Voltage:

        • Busbar connections, right side extension box, bottom cable entry

        • Form wound

        • Low Voltage: Random wound - Internal Excitation - Winding temperature detectors - NEMA Class H insulation, Class H temperature rise at 40C ambient (125C prime/150C standby) - Busbar connections, top center mounted, top cable entry - NEMA standard hole pattern

        • 6 Lead

        • Permanent magnet

        • 3 Phase brushless, salient pole

        • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)

      • Governing System

      • Literature

      • Lubrication System

        • Integral lube oil cool

        • Oil filter, filler and dipstick

        • Oil drain lines and valve

        • Gear type lube oil pump

        • Lubricating oil

        • Fumes disposal

      • Mounting System

        • Rails - engine / generator / radiator mounting

        • Anti-vibration mounts (shipped loose)

        • Rubber anti-vibration mounts (shipped loose)

      • Starting System

        • 24 Volt electric starting motor

        • Battery disconnect switch

        • Battery and battery rack w/cables

        • 45 Amp charging alternator

      • Control System

      • Air Inlet System

        • Single element filter

        • Dual element air cleaner

      • Cooling System

        • Standard ambient radiators

        • Water level switch gauges

        • Optional installed ATAAC radiators

        • Optional installed radiators

        • Coolant

        • Standard ambient ATAAC radiators

      • Crankcase System

        • Ventilation system

        • No explosion relief valves

        • Explosion relief valves

      • Exhaust System

      • Fuel System

        • Fuel Priming Pumps (Tier 4) - Manual or electric

        • Primary Fuel Filter

      • General

        • Special paint (Colors other than Caterpillar yellow or high performance paints)

        • US aid emblem

      • Generators and Attachments

        • Space heater

        • Differential current transformers (DCT) 8.7 kV and 15 kV classes

        • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, IE, No. of Leads = 6, Pitch = .6667: 1600 Frame

        • Alternator air cleaner

        • Thermostate for space heater

        • Low / Medium voltage: 380/400/415 volts, 3 phase 1500 rpm. RW, PM, No. of Leads = 6, Pitch = .6667: 1600 and 1800 Frames

        • Generator conversion

      • Instrumentation

      • Lubrication System

        • Oil level regulator

        • Prelube pumps

        • Lube oil in standard sump

      • Mounting System

        • Puck style low efficiency isolators

        • Spring type vibration isolators

        • IBC vibration isolators

      • Power Connections

        • Neutral ground connections

        • Center post busbar

        • Right side power connections

      • Special Tests / Reports

        • Generator set fuel consumption test

        • PGS test report @ 1.0 power factor

        • Standard engine test charge

        • Canadian Standards Association certification

        • generator test report

        • IBC certification

        • OSHPD certification

        • Fuel consumption test

        • Torsional vibration analysis reports

        • PGS test report @ 0.8 power factor

      • Starting and Charging

        • Starter cover

        • Air pressure regulator

        • 10, 20, 35 and 50 amp battery chargers

        • 24 Volt battery set - Dry

        • Jacket water heaters

        • Air starting motors

        • Electric starting motors

        • Engine barring device

      • Extended Service Coverage

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance