THIS IS MY SELECT
Diesel Generator Sets
3516E Low Voltage Generator Set
Standby Rating
93.0 hp
2750 ekW
Prime Power Rating
93.0 hp
2500 ekW
Emissions/Fuel Strategy
93.0 hp
Tier 2, Low NOx
THIS IS MY SELECT
backhoe loader
3516E Low Voltage Generator Set
Standby Rating
93.0 hp
2750 ekW
Prime Power Rating
93.0 hp
2500 ekW
Emissions/Fuel Strategy
93.0 hp
Tier 2, Low NOx
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Standby Rating
93.0 in
93.0 mm
2750 ekW
Prime Power Rating
93.0 in
93.0 mm
2500 ekW
Emissions/Fuel Strategy
93.0 in
93.0 mm
Tier 2, Low NOx
Voltage
93.0 in
93.0 mm
416 to 13,800 Volts
Frequency
93.0 in
93.0 mm
60 Hz
Speed
93.0 in
93.0 mm
1800 rpm
Duty Cycle
93.0 in
93.0 mm
Standby, Mission Critical, Prime
Maximum Rating
93.0 in
93.0 mm
2750 ekW
Minimum Rating
93.0 in
93.0 mm
2500 ekW
-
Engine Model
93.0 in
93.0 mm
3516E, V-16, 4-Stroke, Water-Cooled Diesel
Bore
6.69 in
170 mm
Stroke
8.47 in
215 mm
Displacement
4,765 in³
78.1 l
Compression Ratio
93.0 in
93.0 mm
14.7:1
Aspiration
93.0 in
93.0 mm
ATAAC
Fuel System
93.0 in
93.0 mm
EUI
Governor Type
93.0 in
93.0 mm
Adem™ A5
-
Length - Maximum
303.3 in
7,703 mm
Width - Maximum
104 in
2,640 mm
Height - Maximum
131.6 in
3,342 mm
Dry Weight - Genset (maximum)
40,750 lb
18,480 kg
-
Air Inlet System
-
Single element canister type with service indicator
-
Air cleaner
-
-
Cooling
-
Exhaust
-
Fuel
-
Primary fuel filter with integral water separator
-
Fuel priming pump
-
-
Generator
-
IP23 Protection
-
Matched to the performance and output characteristics of Cat engines
-
-
Power Termination
-
Starting/Charging
-
Heavy-duty starting system
-
Charging alternator
-
-
UNDERCARRIAGE
-
Control Panel
-
Communications:
-
6 Programmable digital inputs
-
Programmable protective relaying functions:
-
Low oil pressure
-
Environmental sealed front face
-
Volts (L-L & L-N)
-
Emergency stop pushbutton
-
Serial annunciator module data link
-
Reverse Power (kW) (32)
-
Engine cycle crank
-
Lamp test
-
Over / under frequency (81 o/u)
-
kW-hr (total)
-
Speed adjust
-
True RMS AC metering, 3-phase, +/-2% accuracy
-
Engine cool-down timer
-
Overcurrent (50/51)
-
Reverse reactive power (kVAr) (32RV)
-
kW (per phase, average & percent)
-
kVAr-hr (total)
-
Generator phase sequence
-
Oil pressure (psi, kPa or bar)
-
Low coolant temperature
-
Amps (per phase & average)
-
Generator mounted - rear facing
-
Over / under voltage (27/59)
-
Low coolant level
-
Accessory module data link
-
kVAr (per phase, average & percent)
-
EMCP 4.2B controller includes:
-
Failure to start (overcrank)
-
2 Programmable relay outputs (Form C)
-
EMCP 4.2B
-
Overspeed
-
2 Programmable digital outputs
-
DC volts
-
Frequency (Hz)
-
High coolant temperature
-
Warning / shutdown with common LED indication of shutdowns for:
-
Operating hours
-
4 Programmable relay outputs (Form A)
-
Coolant temperature
-
Power Factor (per phase & average)
-
Digital indication for:
-
Panel Lights
-
Text alarm / event descriptions
-
Controls:
-
24 Volt DC operation
-
Alarm acknowledge
-
Customer data link (Modbus RTU)
-
kVA (per phase, average & percent)
-
-
Cooling System
-
Caterpillar extended life coolant
-
Coolant drain line with valve
-
Coolant level sensors
-
JWAC
-
Radiator fan and fan drive
-
Fan and belt guards
-
-
Exhaust System
-
Dry exhaust manifold
-
Flanged faced outlet(s)
-
-
Fuel System
-
Secondary fuel filters
-
Flexible fuel lines - shipped loose
-
Fuel cooler; not included with packages without radiator
-
Fuel priming pump
-
-
Generators and Attachments
-
Form wound
-
3 Phase brushless, salient pole
-
Class H insulation, Class F temperature rise at 40C ambient (105C prime/130C standby)
-
Winding temperature detectors
-
Permanent magnet
-
Anti condensation space heater
-
Right side extension terminal box, bus bar connections, top mounted, bottom cable entry
-
6 Lead
-
NEMA standard hole pattern
-
-
Governing System
-
Literature
-
Lube System
-
Integral lube oil cooler
-
Fumes disposal
-
Oil drain lines and valve
-
Oil filter, filler and dipstick
-
Lubricating oil
-
Gear type lube oil pump
-
-
Mounting System
-
Rubber anti-vibration mounts (shipped loose)
-
Rails - engine/generator/radiator mounting
-
-
Starting / Charging System
-
Battery disconnect switch
-
45 Amp charging alternator
-
Battery and battery rack w/cables
-
24 Volt electric starting motor
-
-
General
-
Flywheel and flywheel housing-SAE No. 00
-
SAE standard rotation
-
Paint: Caterpillar yellow with high gloss black rails & radiator
-
Right hand servicing
-
-
Air Inlet System
-
Air inlet protection
-
Remote air inlet adapters
-
Dual element air cleaners
-
Heavy duty air cleaners
-
-
Circuit Breakers
-
Busbar connections
-
P Frame breaker connections
-
R Frame breaker connections
-
Optional busbar power connections
-
Circuit breaker harnesses
-
Masterpact breaker connections
-
Cable entry options
-
2000, 2500, 3200, 4000 Amp, 4 Pole, IEC-Rated Circuit Breakers
-
2000, 2500, 3200, 4000, 5000 Amp, 3 Pole, IEC Rated Circuit Breakers
-
1600, 2000, 2500, 3000, 4000, 5000 Amp, 3 Pole, UL-100% Rated Circuit Breakers
-
-
Power Termination
-
Control Panel
-
Customer interface options
-
Mounting group - External box clips
-
EMCP 4.3, EMCP 4.4
-
PC monitoring (Remote and local)
-
Ground
-
Load share module options
-
Annunciator modules
-
Auxiliary box
-
Language options
-
Remote speed adjust
-
Vandal proof panel door
-
Voltage raise / lower switch
-
Generator temperature monitoring
-
-
Cooling System
-
Expansion tanks
-
Optional Serpentine radiators
-
Water level switch gauges
-
Optional ATAAC radiators
-
-
Exhaust System
-
Flexible fittings
-
Elbows
-
Flanges and exhaust fittings
-
Flanges
-
Y Adapters
-
Mufflers
-
-
Fuel System
-
Duplex fuel filters
-
Primary fuel filters
-
-
Generators and attachments
-
Differential current transformers - 8.7 and 15 kV class
-
Alternator air cleaners
-
-
Instrumentation
-
Lube System
-
Manual prelube pum
-
Lube oil in standard sump
-
Oil level regulator
-
Electric prelube pump
-
-
Mounting System
-
Spring type vibration isolators
-
IBC seismic vibration isolators NORAD
-
Puck style low efficiency lsolators
-
-
Power Connections
-
Neutral ground connections
-
2700 & 3000 Frame
-
Grounding groups
-
-
Special Tests / Reports
-
IBC certifications
-
Generator set test report
-
Torsional vibration analysis
-
PGS test report @ 1.0 power factor
-
PGS test report @ 0.8 power factor
-
Standard engine test charge
-
Fuel consumption test
-
Generator set consumption test
-
-
Starting / Charging System
-
Starter covers
-
Electric starting motors
-
Air pressure regulator
-
24 Volt battery set - Dry
-
Jacket water heaters
-
Engine barring group
-
10, 20, 35 and 50 Amp battery chargers
-
Air starting motors
-
-
General
-
Special paint colors
-
US aid emblem
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance