THIS IS MY SELECT

Diesel Generator Sets

C13 Generator Set

Maximum Rating

93.0 hp

400 ekW

Minimum Rating

93.0 hp

320 ekW

Emissions/Fuel Strategy

93.0 hp

EPA Stationary Emerg Use

THIS IS MY SELECT

backhoe loader

C13 Generator Set

Maximum Rating

93.0 hp

400 ekW

Minimum Rating

93.0 hp

320 ekW

Emissions/Fuel Strategy

93.0 hp

EPA Stationary Emerg Use

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Maximum Rating

        93.0 in

        93.0 mm

        400 ekW

        Minimum Rating

        93.0 in

        93.0 mm

        320 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        EPA Stationary Emerg Use

        Voltage

        93.0 in

        93.0 mm

        208 to 600 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Prime

      • Engine Model

        93.0 in

        93.0 mm

        C13 ACERT In-line 6, 4-cycle diesel

        Bore

        5.12 in

        130 mm

        Stroke

        6.2 in

        157 mm

        Displacement

        763 in³

        12.5 B

        Compression Ratio

        93.0 in

        93.0 mm

        16.3:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged Air to Air Aftercooled

        Fuel System

        93.0 in

        93.0 mm

        MEUI

        Governor Type

        93.0 in

        93.0 mm

        Adem™A4

      • Length - Maximum

        186.7 in

        4,743 mm

        Width - Maximum

        79.3 in

        2,014 mm

        Height - Maximum

        84 in

        2,133 mm

      • Air Inlet System

        • Turbocharger

        • Aftercooler core

        • Air cleaner; light duty with disposable paper filter

      • Starting / Charging

        • Charging alternator

        • 24-Volt electric starting motor

      • Control Panel

      • Control System Controller

      • Cooling System

        • Fan drive, battery charging alternator drive

        • Caterpillar Extended Life Coolant

        • Coolant drain line with valve

        • Radiator and cooling fan with guard

      • Certification

      • Exhaust System

      • Base / Fuel Tank

      • Fuel System

        • Standard open set fuel tank / base supplied

        • Base, formed steel with single wall integral 8-hour fuel tank

      • Protection

        • Safety Shutoff - Overspeed

        • Safety Shutoff - Low Oil Pressure

        • Safety Shutoff - High water temperature

      • Generator and Attachments

        • Segregated low voltage (AC/DC) wiring panel

        • Power center, IP22

        • A frame generator - IP21 Protection

        • Integrated Voltage Regulator

        • Optional LC frame generator - IP23 Protection

        • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre

      • Governing System

      • Lube System

        • Oil Cooler

        • Oil drain valves

        • Lubricating oil

      • Mounting System

        • Includes lifting provisions and termination points for coolant and lube oil drain lines

        • Captive linear vibration isolators between base and engine-generator

      • Starting / Charging System

      • General

      • European Certificates

        • Global certificate for CIS

        • EU certificate of conformance

      • Air Inlet System

        • Single element air cleaner

        • Dual element air cleaner

      • Circuit Breakers

        • Pad-lockable circuit breaker device

        • 3 Pole (IEC-100% rated) circuit breaker

        • Shunt trip for IEC circuit breaker

        • 4 Pole (IEC-100% rated) circuit breaker - Motorised

        • Circuit breaker (IEC) auxiliary contacts

        • 4 Pole (IEC-100% rated) circuit breaker

        • Power terminal strip

        • 3 Pole (IEC-100% rated) circuit breaker - Motorised

      • Control Panels

        • Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; Overload shutdown via breaker ; low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor

        • EMCP 4.3, EMCP 4.4

        • Volt free contacts

        • Local alarm modules: Local annunciator

        • Remote annunciator modules

      • Cooling System

        • Radiator duct flange

        • Stone guards

        • Low coolant temperature alarm

      • Enclosures

        • Sound attenuated enclosures

        • High ambient sound attenuated enclosures

      • Exhaust System

        • Flexible 8 inch exhaust fittings

        • Mufflers - End in / End out

        • 10, 25 and 35 dBA attenuation

        • 6 and 8 inch elbow kit

        • 6 and 8 inch flange GP

      • Fuel System

        • Fuel transfer system controls

        • Manual fuel transfer pump

        • Integral dual wall fuel tank base

      • Generator and Attachments

        • LC frame generator

        • LC CIP generator

        • Space heaters

        • Ingress protection

        • A frame oversize generator

        • Permanent magnet generator

        • A frame CIP generator

      • Lube System

      • Mounting System

      • starting / Charging System

        • Battery disconnect switch

        • Jacket water heater

        • 5 Amp single battery charger

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN