THIS IS MY SELECT
Diesel Generator Sets
C175-16 Generator Set
Standby Rating
93.0 hp
3365(no fan)/3250/3100(no fan)/3000 ekW
Prime Power Rating
93.0 hp
3115(no fan)/3000/2825(no fan)/2725 ekW
Emissions/Fuel Strategy
93.0 hp
Low Fuel, Tier 2
THIS IS MY SELECT
backhoe loader
C175-16 Generator Set
Standby Rating
93.0 hp
3365(no fan)/3250/3100(no fan)/3000 ekW
Prime Power Rating
93.0 hp
3115(no fan)/3000/2825(no fan)/2725 ekW
Emissions/Fuel Strategy
93.0 hp
Low Fuel, Tier 2
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Standby Rating
93.0 in
93.0 mm
3365(no fan)/3250/3100(no fan)/3000 ekW
Prime Power Rating
93.0 in
93.0 mm
3115(no fan)/3000/2825(no fan)/2725 ekW
Emissions/Fuel Strategy
93.0 in
93.0 mm
Low Fuel, Tier 2
Voltage
93.0 in
93.0 mm
480 to 13800 Volts
Frequency
93.0 in
93.0 mm
60 Hz
Speed
93.0 in
93.0 mm
1800 RPM
Duty Cycle
93.0 in
93.0 mm
Standby, Mission Critical, Prime, Continuous
Maximum Rating
93.0 in
93.0 mm
3365 ekW
Minimum Rating
93.0 in
93.0 mm
2500 ekW
-
Engine Model
93.0 in
93.0 mm
C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel
Bore
6.89 in
175 mm
Stroke
8.66 in
220 mm
Displacement
6,456.31 in³
84.7 l
Compression Ratio
93.0 in
93.0 mm
16.7:1
Aspiration
93.0 in
93.0 mm
Turbo Aftercooled
Fuel System
93.0 in
93.0 mm
Common Rail
Governor Type
93.0 in
93.0 mm
ADEM� A4
-
Length - Minimum
241.6 in
6,137 mm
Length - Maximum
312.9 in
7,947 mm
Width - Minimum
83.1 in
2,110 mm
Width - Maximum
113.7 in
2,889 mm
Height - Minimum
87 in
2,211 mm
Height - Maximum
134.3 in
3,410 mm
Dry Weight - Genset (minimum)
42,750 lb
19,391 kg
Dry Weight - Genset (maximum)
50,500 lb
22,906 kg
-
Air Inlet System
-
Control Panel
-
2 Programmable relay outputs (Form C)
-
Low coolant level
-
Over / under voltage
-
Coolant temperature
-
Serial annunciator module data link
-
Alarm acknowledge
-
Text alarm/event descriptions
-
Volts (L-L & L-N)
-
Reverse power
-
Over / under frequency
-
Environmental sealed front face
-
Programmable Protective Relaying Functions
-
Speed adjust
-
Generator phase sequence
-
Low coolant temperature
-
Generator mounted - rear facing
-
Overspeed
-
Controls
-
Frequency (Hz)
-
Engine cycle crank
-
Engine cool-down timer
-
Warning / Shutdown Indicators
-
Lamp test
-
2 Programmable digital outputs
-
6 Programmable digital inputs
-
High coolant temperature
-
Customer data link (Modbus RTU)
-
Auto / start / stop control
-
Emergency stop pushbutton
-
RPM
-
Digital Indicators
-
Communications
-
Accessory module data link
-
Oil pressure (psi, kPa or bar)
-
Low oil pressure
-
Overcurrent
-
Emergency stop
-
24 Volt DC operation
-
4 Programmable relay outputs (Form A)
-
Failure to start (overcrank)
-
True RMS AC metering, 3-phase, +/-2% accuracy
-
Power Factor (per phase & average)
-
Operating hours
-
DC volts
-
Amps (per phase & average)
-
EMCP 4.2B
-
Reverse reactive power
-
-
Exhaust System
-
Bolted flange, with bellow for each turbo
-
Exhaust flange outlet
-
-
Fuel System
-
Engine mounted filters #REF!
-
Filters x 3
-
10 Micron spin on yype
-
Secondary / tertiary fuel filters
-
4 Micron spin on type
-
Primary fuel filter water / fuel water separator
-
-
Generators and Attachments
-
Right side extension box, bottom cable entry
-
IEC Platinum stator RTDs
-
Reactive droop capability
-
3 Phase voltage sensing
-
(MV) Busbar connections, right side extension box, bottom cable entry
-
Class F temperature rise at 40C ambient
-
Anti condensation space heater
-
NEMA Class H insulation
-
6 Leads
-
Class H temperature rise at 40C ambient
-
Voltage regulator:
-
Exciter diode monitor
-
Form wound
-
RFI suppression
-
(LV) Busbar connections, top/center mounted, top cable entry
-
3 Phase brushless
-
60 Hz models: NEMA standard hole pattern
-
Permanent magnet
-
Min / max exciter limiter
-
Salient Pole
-
-
Governing System
-
Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
-
ADEM A4
-
-
Lube System
-
Oil filter, filler and dipstick
-
Integral lube oil cooler
-
Oil drain lines and valve
-
Fumes disposal
-
Lubricating oil
-
Prelube - required with prime, continuous, and standby
-
Gear type lube oil pump
-
-
Mounting Systems
-
Rails - Engine / generator
-
Rubber anti-vibration mounts (shipped loose)
-
Dual 24 volt electric starting motors
-
Battery disconnect switch
-
Batteries and battery rack w/cables
-
-
Power Termination
-
Service Instructions
-
General
-
Paint - Caterpillar yellow with high gloss black rails & radiator
-
SAE standard rotation
-
LH Service
-
Flywheel and flywheel housing-SAE No. 00
-
-
Air Inlet System
-
Air inlet adapters
-
Dual element air cleaner
-
Single element air cleaner
-
Air inlet protection
-
-
Control Panel
-
Package mounted radiator
-
Automatically selected ground
-
Customer AC-DC connection mounting location - LV/MV
-
Load share governor
-
EMCP 4.3, EMCP 4.4
-
E-Stop
-
Frame boxes
-
Annunciator modules
-
Load share module / auxiliary plate and auxiliary box (LV)
-
Fuel cooler
-
EMCP mounting location - LV/MV
-
Modbus monitoring of packages
-
Customer interface options
-
EMCP 4.4 optional harness
-
EMCP voltage and current sensing groups
-
Remote radiators
-
Generator harness
-
Interconnect harness
-
Speed adjust
-
EMCP and MV and HV power connection locations
-
Raise lower switch
-
-
Crankcase Systems
-
Explosive relief valves
-
Crankcase ventilation system
-
-
Exhaust System
-
Mufflers
-
Exhaust support group
-
Weld flanges
-
Exhaust collectors / Manifold
-
Front housing - Prime or continuous
-
Front housing - Standby or mission critical
-
Aftercooler drain
-
-
Fuel System
-
Generators and Attachments
-
Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
-
Medium voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
-
Conversion GP-Top cable entry
-
Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
-
Differential current transformers
-
Space heater kit
-
Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
-
Thermostat for space heater
-
Generator air intake
-
-
Instrumentation
-
Lube System
-
Drain group oil pans
-
Oil filters
-
Lube oil heater
-
Electric prelube pumps
-
Lubricating oil
-
-
Mounting Systems
-
IBC vibration isolators - Shipped loose
-
Spring type linear vibration isolators
-
Rubber anti-vibration mounts
-
-
Power Connections
-
Low voltage connection cable
-
Center post busbars (LV)
-
1800 Frame generator side / rear mounted busbars (MV)
-
Enclosures - Control packaging (LV)
-
Paralleling circuit breakers
-
1800 Frame generators circuit breaker
-
Neutral ground (LV)
-
Neutral ground (MV)
-
Cable entry options (LV)
-
Cable entry options (MV)
-
Masterpack breakers
-
Power connection covers (LV)
-
Harnesses (Breaker)
-
Masterpack breaker connections
-
Side / Rear mounted busbars (LV)
-
-
Special Tests / Reports
-
IBC seismic certification
-
Special test charge - Engine only
-
PGS test report @ 0.8 power factor
-
Genset fuel consumption test
-
Standard genset TVA (Torsional vibration analysis) report
-
PGS test report @ 1.0 power factor
-
OSCOSH1 seismic certification
-
Custom genset TVA report
-
Generator test report
-
Standard engine test charge
-
-
Starting / Charging System
-
Heavy duty battery sets with rack
-
Charging alternators - Dry
-
Air pressure regulator
-
Starter location covers
-
24 Volt power distribution box
-
24 Volt electric starting motors
-
35 Amp battery chargers
-
24 Volt battery sets - Dry
-
20 Amp battery chargers
-
Jacket water heaters
-
50 Amp battery chargers
-
Air starting motor
-
Jacket water heater wiring groups
-
-
General
-
Special paint colors
-
Control GP - Air powered bar group
-
Barring group manual
-
Service tools - Engine barring group
-
Engine barring air powered
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance