Diesel Generator Sets

C175-16 Generator Set

Standby Rating

93.0 hp

3100(no fan)/3000 kVA

Prime Power Rating

93.0 hp

2825(no fan)/2725 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel, Low Emissions

THIS IS MY SELECT

backhoe loader

C175-16 Generator Set

Standby Rating

93.0 hp

3100(no fan)/3000 kVA

Prime Power Rating

93.0 hp

2825(no fan)/2725 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel, Low Emissions

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Standby Rating

        93.0 in

        93.0 mm

        3100(no fan)/3000 kVA

        Prime Power Rating

        93.0 in

        93.0 mm

        2825(no fan)/2725 kVA

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Low Fuel, Low Emissions

        Voltage

        93.0 in

        93.0 mm

        380 to 11000 Volts

        Frequency

        93.0 in

        93.0 mm

        50 Hz

        Speed

        93.0 in

        93.0 mm

        1500 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Mission Critical, Prime, Continuous

        Maximum Rating

        93.0 in

        93.0 mm

        3100 kVA

        Minimum Rating

        93.0 in

        93.0 mm

        2500 kVA

      • Engine Model

        93.0 in

        93.0 mm

        C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel

        Bore

        6.89 in

        175 mm

        Stroke

        8.66 in

        220 mm

        Displacement

        5,166.88 in³

        84.7 l

        Compression Ratio

        93.0 in

        93.0 mm

        16.7:1

        Aspiration

        93.0 in

        93.0 mm

        Turbo Aftercooled

        Fuel System

        93.0 in

        93.0 mm

        Common Rail

        Governor Type

        93.0 in

        93.0 mm

        ADEM� A4

      • Length - Minimum

        241.6 in

        6,137 mm

        Length - Maximum

        311 in

        7,900 mm

        Width - Minimum

        83 in

        2,110 mm

        Width - Maximum

        108.5 in

        2,786 mm

        Height - Minimum

        87 in

        2,211 mm

        Height - Maximum

        130.2 in

        3,307 mm

        Dry Weight - Genset (minimum)

        42,750 lb

        19,391 kg

        Dry Weight - Genset (maximum)

        50,750 lb

        23,020 kg

      • Air Inlet System

      • Control Panel

        • EMCP 4.2B

        • Volts (L-L & L-N)

        • Engine cycle crank

        • Power Factor (per phase & average)

        • Overcurrent

        • Communications

        • Emergency stop

        • 2 Programmable relay outputs (Form C)

        • 6 Programmable digital inputs

        • 2 Programmable digital outputs

        • Environmental sealed front face.

        • DC Volts

        • Reverse power

        • Programmable Protective Relaying Functions

        • High coolant temperature

        • Accessory module data link

        • Low coolant level

        • Over / under frequency

        • Amps (per phase & average)

        • True RMS AC metering, 3-phase, +/-2% accuracy

        • Low coolant temperature

        • Reverse Reactive Power

        • Controls

        • Oil pressure (psi, kPa or bar)

        • Lamp test

        • Coolant temperature

        • Warning / shutdown Indicators

        • 4 Programmable relay outputs (Form A)

        • Alarm acknowledge

        • Generator phase sequence

        • 24 Volt DC operation

        • Serial annunciator module data link

        • Customer data link (Modbus RTU)

        • Failure to start (overcrank)

        • Auto / start / stop control.

        • Low oil pressure

        • RPM

        • Text alarm / event descriptions.

        • Digital Indicators

        • Generator mounted - rear facing

        • Emergency stop pushbutton

        • Engine cool-down timer.

        • Operating hours

        • Over / under voltage

        • Overspeed

        • Frequency (Hz)

      • Cooling System

        • Radiator group - shipped loose

        • SCAC cooling

        • Coolant Sensors

        • Coolant drain line and valves

        • Fan and belt guards

      • Exhaust System

        • Bolted flange, with bellow for each turbo

        • Dry Exhaust Manifold

      • Fuel System

        • Filters x 3

        • Secondary / Tertiary fuel filters

        • 10 Micron Spin On Type

        • 4 Micron Spin On Type

        • Primary fuel filter water / fuel water separator

        • Engine mounted filters X3

      • Generator and Attachments

        • 6 Leads

        • IEC platinum stator RTDs

        • Voltage regulator

        • Reactive droop capability

        • 3 Phase voltage sensing

        • RFI suppression

        • Min / max exciter limiter

        • exciter diode monitor

        • Form Wound

        • Permanent magnet

        • NEMA Class H insulation

        • Class H temperature rise at 40C ambient

        • (LV) Busbar connections, top/center mounted, top cable entry

        • 3 Phase Brushless

        • Salient pole

        • 50 Hz models: IEC standard hole pattern

        • (MV) Busbar connections, right side extension box, bottom cable entry

        • Anti condensation space heater

        • Class F temperature rise at 40C ambient

        • Right side extension box, bottom cable entry

      • Governing System

        • ADEM A4

        • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)

      • Lube System

        • Gear type lube oil pump

        • Lubricating oil

        • Fumes disposal

        • Integral lube oil cooler

        • Oil drain lines and valve

        • Oil filter, filler and dipstick

        • Prelube - required with prime, continuous, and standby

      • Mounting Systems

        • Rubber anti-vibration mounts (shipped loose)

        • Battery disconnect switch

        • Batteries and battery rack w/cables

        • Dual 24 volt electric starting motors

        • Rails - Engine / generator

      • Service Instructions

      • Power Termination

      • General

        • Paint - Caterpillar yellow with high gloss black rails & radiator

        • Right hand service

        • Flywheel and flywheel housing-SAE No. 00

        • SAE standard rotation

      • Air Inlet System

        • Single element air cleaner

        • Dual element air cleaner

        • Air inlet adapters

        • Air inlet protection

      • Control Panel

        • EMCP 4.3, EMCP 4.4

        • EMCP 4.4 optional harness

        • EMCP and MV&HV power connection locations

        • Load share module

        • EMCP mounting location - LV / MV

        • Customer AC-DC connection mounting location - LV/MV

        • Load share module / auxiliary plate and auxiliary box (LV)

        • Load share governor

        • Frame boxes

        • Automatically selected ground

        • EMCP voltage and current sensing groups

        • Raise lower switch

        • Speed adjust

        • Annunciator modules

        • Customer interface options

        • Generator temperature monitoring

        • Modbus monitoring of packages

        • E-Stop

        • Interconnect harness

        • Generator Harness

      • Cooling System

        • Package mounted radiator

        • Remote radiators

        • Fuel cooler

      • Exhaust System

        • Front housing - Standby or mission critical

        • Front housing - Prime or continuous

        • Exhaust collectors / Manifold

        • Exhaust support group

        • Mufflers

        • Weld flanges

        • Aftercooler drain

      • Crankcase Systems

        • Explosive relief valves

        • Crankcase ventilation system

      • Fuel System

      • Generators and Attachments

        • Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667

        • Medium Voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667

        • Low Voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667

        • Space heater kit

        • Thermostat for space heater

        • Conversion GP-Top cable entry

        • Generator air intake

        • Differential current transformers

      • Instrumentation

      • Lube System

        • Lube oil heater

        • Drain group oil pans

        • Lubricating oil

        • Electric prelube pumps

        • Oil filters

      • Mounting

        • Rubber anti-vibration mounts

        • Spring type linear vibration isolators

        • IBC vibration isolators - Shipped loose

      • Power Connections

        • Center post busbars (LV)

        • Side / Rear mounted busbars (LV)

        • Harnesses (Breaker)

        • Cable entry options (LV)

        • Enclosures - Control packaging (LV)

        • Power connection covers (LV)

        • Neutral ground (LV)

        • 1800 Frame generators circuit breaker

        • Masterpack breakers

        • Paralleling circuit breakers

        • 1800 Frame generator side / rear mounted busbars (MV)

        • Cable entry options (MV)

        • Neutral ground (MV)

        • Low voltage connection cable

        • Masterpack breaker connections

      • Special Tests / Reports

        • Generator test report

        • PGS test report @ 1.0 power factor

        • PGS test report @ 0.8 power factor

        • Standard genset TVA (Torsional Vibration Analysis) report

        • Custom genset TVA report

        • Special test charge - Engine only

        • Genset fuel consumption test

        • Standard engine test charge

        • IBC seismic certification

        • OSCOSH1 seismic certification

      • Starting / Charging System

        • 24 Volt power distribution box

        • 24 Volt electric starting motors

        • Air starting motor

        • Air pressure regulator

        • Starter location covers

        • 24 Volt battery sets - Dry

        • Heavy duty battery sets with rack

        • 20 Amp battery chargers

        • 35 Amp battery chargers

        • 50 Amp battery chargers

        • Charging alternators - Dry

        • Jacket water heaters

        • Jacket water heater wiring groups

      • General

        • Special paint colors

        • Service tools - Engine barring group

        • Barring group manual

        • Engine barring air powered

        • Control GP - Air powered bar group

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN