Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Maximum Rating

        93.0 in

        93.0 mm

        500 ekW

        Minimum Rating

        93.0 in

        93.0 mm

        455 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        U.S. EPA Tier 4 Final

        Voltage

        93.0 in

        93.0 mm

        480 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Prime

      • Engine Model

        93.0 in

        93.0 mm

        C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel

        Bore

        1,455.7 in

        145 mm

        Stroke

        7.2 in

        183 mm

        Displacement

        1,106.4 in³

        18.1 l

        Compression Ratio

        93.0 in

        93.0 mm

        14.5:1

        Aspiration

        93.0 in

        93.0 mm

        Air to Air Aftercooled

        Fuel System

        93.0 in

        93.0 mm

        Electronic unit injection

        Governor Type

        93.0 in

        93.0 mm

        Adem™A4

      • Air Inlet

      • Exhaust System

      • Cooling

      • Fuel System

        • Fuel cooler

        • Engine fuel transfer pump

        • Primary fuel filter w/integral water separator & secondary filter

        • Fuel priming pump

        • Flexible fuel lines

      • Exhaust

      • Fuel

        • Primary fuel filter with integral water separator

        • Fuel priming pump

        • Secondary fuel filter

      • Generator

        • Matched to the performance and output characteristics of Cat engines

        • IP23 Protection

        • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

      • Power Termination

      • Lube System

        • Oil filter and dipstick

        • Lubricating oil

        • Oil drain lines with valve; piped to edge of base

        • Fumes disposal; piped to front of radiator

        • Oil cooler

      • Control Panel

      • Mounting

      • Protection System

      • Cooling System

        • Thermostats and housing, full open temperature 92 deg C (198 deg F)

        • Coolant Level Sensor

        • Coolant level sight gauge.

        • Fan and belt guards

        • Jacket water pump, gear driven, centrifugal

        • Coolant drain line with valve; terminated on edge of base

        • Caterpillar Extended Life Coolant

      • Starting/Charging

        • 24V, 45 amp charging alternator.

        • 24-volt electric starting motor

        • 24 volt starting motor

        • Batteries

      • General

        • Paint - Caterpillar Yellow except rails and radiators gloss black

        • Paint, Caterpillar yellow

        • Operation and maintenance manual pack and OMM Storage Compartment

        • Parts book

        • Vibration damper

      • Control System

        • Local annunciator

        • Programmable Input / Output: 2 programmable digital inputs - 2 programmable relay outputs (Form A) - 2 programmable relay outputs (Form C)

        • Suitable for use as service equipment label

        • Separation plate

        • Control panel mounting location

        • Breaker box mounting location

        • Optional external analog input

        • Remote annunciators

        • EMCP 4.2

        • Communications: Customer data link (RS485 Modbus RTu) - Serial annunciator module data link for local and remote annunciator IVR - Integrated Voltage Regulation (Digital) - EM10 Excitation Module

        • Controls include: Run / auto / stop control - Speed adjust - Voltage adjust - Engine cycle crank - Emergency stop pushbutton

        • Digital indication for: rpm - DC volts - operating hours - Oil pressure (psi, kPa or bar) - Coolant temperature (C or F) - Volts (L-L & L-N), frequency (Hz) - Amps (per phase & average) - Power factor (per phase & average) - kW (per phase & average) - kVA (per phase & average) - kVAr (per phase and average) - kW-hr (total) - kVAr-hr (total)

        • Programmable protective relaying functions: Generator phase sequence - Over / Under voltage (27/59) - Over / Under frequency (81 o/u) - Overcurrent (50/51)

        • Warning / Shutdowns with common LED indication of shutdowns for: Low oil pressure - high coolant temperature - Overspeed - Emergency stop - Failure to start (overcrank) - Low coolant temperature - Low coolant level

        • Control panel options: Dust proof control panel - volt free contact - Device server - Ground fault relay

      • Governing System

      • Generator and Attachments

        • Segregated low voltage (AC/DC) wiring panel

        • Brushless, self-excited 2/3 pitch, random wound.

        • Insulation Class H and temperature rise

        • AREP generator

        • CIP - generators

        • IP23 Protection

        • Power center, IP22 bottom cable entry

      • Air Inlet System

        • Single element air filter

        • Air cleaner - Heavy duty

        • Air cleaner - Single element

      • Extended Service Coverage

      • Circuit breakers

      • Control System

        • Ground fault relay

        • Dust proof control panel

        • Breaker box mounting location

        • Volt free contact

        • Device server

        • Separation plate

        • Remote annunciators

        • EMCP 4.4

        • Local annunciator

        • Remote E-stop button

        • Optional external analog input

        • Control panel mounting

      • Exhaust

      • Generator

        • Anti-condensation heater

        • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)

        • Oversize and premium generators

      • Power Termination

      • Generators and Attachments

        • AREP Generator

        • CIP generators

        • Space heater

        • Generator mounting and duct plate

      • Air Inlet System

        • Single element air filter

        • Dual element air cleaner

      • Certifications

        • Certificate of compliance

        • IBC certification wind load

      • Circuit breakers

        • Motorized single circuit breaker

        • Neutral bars

        • Power cables

        • Dual breakers first circuit breaker (CB2) LS/I package mounted

        • Current transformers

        • Package mounted single circuit breakers

        • Dual breakers first circuit breaker (CB1) LS/I package mounted

        • Auxiliary contacts

      • Cooling System

        • Aftertreatment guard

        • Standard radiator

      • Enclosures

      • Exhaust System

        • Flange kits

        • Exhaust flexible fittings

      • Fuel System

      • Generator Attachments

      • Mounting System

        • Standard base Wide

        • 5 gallon spill containment

        • Optional CB shroud

        • Overfill prevention valve

        • Locking fuel fill

      • Starting / Charging System

        • Battery disconnect switch

        • Jacket water heater

        • Shore power control group

        • 10 Amp dual battery charger

      • TESTS

        • PGS test report @ 0.8 power factor

        • 4 Hour factory test (un-witnessed)

        • PGS test report @ 1.0 power factor

        • Generator test report

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN