THIS IS MY SELECT

Diesel Generator Sets

C18 Generator Set

Maximum Rating

93.0 hp

715 kVA

Minimum Rating

93.0 hp

550 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel, China Nonroad III Emis Stds

THIS IS MY SELECT

backhoe loader

C18 Generator Set

Maximum Rating

93.0 hp

715 kVA

Minimum Rating

93.0 hp

550 kVA

Emissions/Fuel Strategy

93.0 hp

Low Fuel, China Nonroad III Emis Stds

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Maximum Rating

        93.0 in

        93.0 mm

        715 kVA

        Minimum Rating

        93.0 in

        93.0 mm

        550 kVA

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Low Fuel, China Nonroad III Emis Stds

        Voltage

        93.0 in

        93.0 mm

        380 to 415 Volts

        Frequency

        93.0 in

        93.0 mm

        50 Hz

        Speed

        93.0 in

        93.0 mm

        1500 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Prime

      • Engine Model

        93.0 in

        93.0 mm

        C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel

        Bore

        5.71 in

        145 mm

        Stroke

        7.2 in

        183 mm

        Displacement

        1,106.36 in³

        18.13 l

        Compression Ratio

        93.0 in

        93.0 mm

        14.5:1

        Aspiration

        93.0 in

        93.0 mm

        Air to Air Aftercooled

        Fuel System

        93.0 in

        93.0 mm

        Electronic unit injection

        Governor Type

        93.0 in

        93.0 mm

        Ademâ„¢A4

      • Length - Maximum

        162.4 in

        4,135 mm

        Width - Maximum

        78.3 in

        1,989 mm

        Height - Maximum

        75 in

        1,906 mm

      • Air Inlet System

        • Turbocharger

        • Light duty air cleaner

        • Aftercooler core

      • Air Inlet

      • Control System

      • Exhaust

      • Cooling

        • Coolant drain line with valve

        • Caterpillar extended life coolant

        • Fan drive, battery charging alternator drive

        • Radiator and cooling fan with guard

      • Exhaust System

      • Fuel

        • Secondary fuel filter

        • Fuel priming pump

        • Primary fuel filter with integral water separator

      • Fuel System

      • Generator

        • IP23 Protection

        • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time

        • Matched to the performance and output characteristics of Cat engines

      • Generator and Attachments

        • Segregated low voltage (AC/DC) wiring panel

        • Integrated Voltage Regulator

        • A frame generator - IP21 protection

        • Integrated Voltage Regulator

        • Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre

        • Power center, IP22

        • Matched to the performance and output characteristics of Cat engines

      • Power Termination

      • Governing System

      • Control Panel

      • Lube System

        • Lubricating oil

        • Oil drain valves

      • Mounting

      • Mounting System

      • Starting/Charging

      • General

      • Exhaust

      • Air Inlet System

        • Dual element air cleaner

        • Single element air cleaner

      • Circuit Breakers

        • 3 Pole (IEC-100% rated) circuit breakers - Motorised

        • 4 Pole (IEC-100% rated) circuit breakers - Motorised

        • Circuit breaker (IEC) auxiliary contacts

        • Pad-lockable circuit breaker device

        • 3 Pole (IEC-100% rated) circuit breakers - Package mounted

        • 4 Pole (IEC-100% rated) circuit breakers - Package mounted

        • Power terminal strip

        • Shunt trip for IEC breaker

      • Generator

        • Anti-condensation heater

        • Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)

        • Oversize and premium generators

      • Power Termination

        • Circuit breakers, IEC compliant

        • Circuit breakers, UL listed

      • Control Panels

        • Local & remote annunciator modules

        • Load share module

        • Remote monitoring software

        • EMCP (4.2) (4.3) (4.4)

        • Digital I/O module

      • Control System

        • Oil temperature displays

        • EMCP 4.4

        • Volt free contact

        • Protective devices: Earth fault relay - earth leageage ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - high fuel level alarm - Fuel level sensor

        • Local alarm modules

        • Remote annunciator modules

        • Local alarm horn

      • Cooling System

        • Low coolant temperature alarm

        • Radiator duct flange

      • Starting/Charging

        • Oversize batteries

        • Jacket water heater

        • Battery chargers

        • Heavy-duty starting system

        • Charging alternator

      • Enclosures

      • Exhaust System

        • Manifold and Turbocharger guard

        • Engine mounted muffler

        • 8 and 10 inch elbow kits

        • 8 and 10 inch GP flanges

        • 10, 25 and 35 end in / end outmufflers

      • Fuel System

        • Integral - Duel wall fuel tank base

        • Manual fuel transfer pump

        • Fuel transfer system

      • Generator and Attachments

        • LC frame generator

        • Permanent magnet excitation

        • LC frame oversize generators

        • Space heaters

        • A frame oversize generator

        • A frame CIP generator

        • Ingress protection

        • LC frame CIP generator

      • General

        • Single or dual wall integral fuel tanks

        • UL 2200 package

        • Enclosures: sound attenuated, weather protective

        • EU Certificate of Conformance (CE)

        • Integral & sub-base UL listed dual wall fuel tanks

        • Narrow, Wide or Skid Base

        • The following options are based on regional and product configuration:

        • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007

        • EEC Declaration of Conformity

        • CSA Certification

        • Sound attenuated, weather protective or high ambient weather protective enclosure

        • Automatic transfer switches (ATS)

        • Single or dual wall sub-base fuel tanks

      • Lube System

      • Starting and Charging

        • Jacket water heaters

        • 5 Amp battery charger

        • Battery disconnect switch

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN