THIS IS MY SELECT

Diesel Generator Sets

C3.3 Generator Set

Minimum Rating

93.0 hp

24.0 kVA

Maximum Rating

93.0 hp

65.0 kVA

Emissions/Fuel Strategy

93.0 hp

EU Stage II R96/EUIIIa

THIS IS MY SELECT

backhoe loader

C3.3 Generator Set

Minimum Rating

93.0 hp

24.0 kVA

Maximum Rating

93.0 hp

65.0 kVA

Emissions/Fuel Strategy

93.0 hp

EU Stage II R96/EUIIIa

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Minimum Rating

        93.0 in

        93.0 mm

        24.0 kVA

        Maximum Rating

        93.0 in

        93.0 mm

        65.0 kVA

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        EU Stage II R96/EUIIIa

        Voltage

        93.0 in

        93.0 mm

        110 to 480 Volts

        Frequency

        93.0 in

        93.0 mm

        50 Hz

        Speed

        93.0 in

        93.0 mm

        1500 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby, Prime

      • Engine Model

        93.0 in

        93.0 mm

        Cat® C3.3

        Bore

        4.1 in

        105 mm

        Stroke

        5 in

        127 mm

        Displacement

        201.4 in³

        3.3 l

        Compression Ratio

        93.0 in

        93.0 mm

        17.25:1, 19.25:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged

        Fuel System

        93.0 in

        93.0 mm

        Direct Injection

        Governor Type

        93.0 in

        93.0 mm

        Mechanical

      • Length - Maximum

        43.9 in

        1,115 mm

        Width - Maximum

        38.2 in

        970 mm

        Height - Maximum

        53.6 in

        1,361 mm

      • Air Inlet System

      • Control Panel

      • Cooling System

        • Coolant drain line with valve

        • Radiator and cooling fan with guards

        • Caterpillar extended life coolant

        • Fan drive, battery charging alternator drive

      • Exhaust System

      • Fuel System

        • Standard open set fuel tank / base supplied

        • Base, formed steel with single wall integral 8-hour fuel tank

      • Generators and Generator Attachments

        • Voltage regulator (single phase sensing)

        • Tower panel, IP22, bottom cable entry

        • Circuit breaker, IEC, 3 pole, mounted in tower panel

        • IP23 Protection

        • Segregated low voltage (AC/DC) wiring panel

      • Governing System

      • Generators and attachments

      • Lube System

        • Lubricating oil

        • Oil drain line with valve

      • Mounting System

        • Captive linear vibration isolators between base and engine-generator

        • Termination points for coolant and lube oil drain lines

        • Includes lifting provision and drag points

      • Starting / Charging System

      • General

      • Alternator System

        • R frame auxilliary winding

        • Anti-condensation heater

        • LC frame alternator with coastal protection

        • LC frame alternator

        • Permanent magnet

      • Circuit Breakers

        • Pad-lockable breaker device

        • 4 Pole circuit breaker to 250A

      • Control Panels

      • Control Panel Options

      • Cooling System

        • low coolant level shutdown

        • Coolant heater

        • Low coolant temperature alarm

      • Certifications

        • Global Certification for CIS

        • European Upgrade to STD set for 'CE'

      • Enclosures

        • Sound attenuated level 1 enclosure (GALV)

        • CEE for sockets for enclosure

        • Sound attenuated level 2 enclosure CE

        • Rental pack (CAE only)

        • Socket blanking plate

      • Fuel System

        • High fuel level alarm

        • Open set narrow tankbase

        • Compact skidbase for open sets

        • Low fuel level shutdown

        • Low fuel level alarm

        • Skidbase for CALG enclosure sets

        • Bunded fuel tank

      • Mounting Options

        • Battery removal

        • Residential Silencer

        • Silencer installation kit

        • External single point lift - enclosure

        • Electronic governor

      • Special Packing Inspections

        • PGS test report @ 0.8 power factor

        • PGS test report @ 1.0 power factor

      • General

        • Packing case, compact set

        • Packing case, canopied set

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN