THIS IS MY SELECT
Diesel Generator Sets
C4.4 Generator Set
Maximum Rating
93.0 hp
60 ekW
Minimum Rating
93.0 hp
36 ekW
Emissions/Fuel Strategy
93.0 hp
U.S. EPA Cert., Tier 3
THIS IS MY SELECT
backhoe loader
C4.4 Generator Set
Maximum Rating
93.0 hp
60 ekW
Minimum Rating
93.0 hp
36 ekW
Emissions/Fuel Strategy
93.0 hp
U.S. EPA Cert., Tier 3
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Maximum Rating
93.0 in
93.0 mm
60 ekW
Minimum Rating
93.0 in
93.0 mm
36 ekW
Emissions/Fuel Strategy
93.0 in
93.0 mm
U.S. EPA Cert., Tier 3
Voltage
93.0 in
93.0 mm
208 to 600 Volts
Frequency
93.0 in
93.0 mm
60 Hz
Speed
93.0 in
93.0 mm
1800 rpm
Duty Cycle
93.0 in
93.0 mm
Standby, Prime
-
Engine Model
93.0 in
93.0 mm
C4.4, In-line 4, 4-cycle diesel
Bore
4.13 in
105 mm
Stroke
5 in
127 mm
Displacement
268.5 in
4.4 l
Compression Ratio
93.0 in
93.0 mm
18.2:1
Aspiration
93.0 in
93.0 mm
Turbocharged
Fuel System
93.0 in
93.0 mm
Electronic (adjustable)
Governor Type
93.0 in
93.0 mm
Adem™A4
-
Length - Maximum
75.8 in
1,925 mm
Width - Maximum
44.1 in
1,120 mm
Height - Maximum
53.6 in
1,361 mm
-
Certificates
-
Charging System
-
Air Inlet System
-
Air cleaner
-
Cartridge type air filter
-
-
Circuit Breakers
-
Second circuit breaker box
-
3-Pole 100% rated
-
Power perminal strips
-
Breakers (100% UL rated)
-
-
Control Panel
-
Exhaust System
-
Fuel System
-
Cooling System
-
Coolant drain line with valve
-
Radiator and cooling fan with guards
-
Fan drive, battery charging alternator drive
-
Caterpillar extended life coolant
-
Radiator stone guard
-
-
Generator
-
Governing System
-
Lube System
-
Oil drain line with valve
-
Lubricating oil
-
-
Control Panels
-
WCA1 Low coolant temperature alarm
-
WSS1 Low coolant level shut down
-
FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected
-
NFPA110 bundle includes:
-
PAA1 Panel mounted audible alarm
-
A coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
-
Oil temperature guage and sender
-
PBC10NU NFPA Battery Charger
-
Ground fault relay
-
Discrete I/O module
-
Volt free contacts genset run and common alarm
-
Audible alarm
-
Remote E-stop button
-
Remote annunciator
-
Low coolant temperature alarm
-
Protective devices:
-
Overload shutdown via breaker
-
Fuel level reading
-
Low coolant level shutdown
-
-
General
-
Starting/Charging System
-
24V battery with rack and cables
-
Batteries
-
-
Certificates
-
Alternator System
-
Air Inlet System
-
Charging System
-
Circuit Breakers
-
3-Pole 100% rated
-
Breakers (100% UL rated)
-
Second circuit breaker box
-
Power perminal strips
-
-
Control Panels
-
Discrete I/O module
-
Remote annunciator
-
Remote E-stop button
-
Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
-
Ground fault relay
-
Audible alarm
-
Oil temperature guage and sender
-
Volt free contacts genset run and common alarm
-
NFPA110 bundle includes: FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low Coolant level shut down - WCA1 Low Coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA Battery Charger - A coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
-
-
Heating Elements
-
Coolant heater
-
Battery heater
-
Anti-condensation heater
-
Lube oil sump heater
-
Jacket water heater
-
Wiring for canopy space heater
-
-
Cooling System
-
Enclosures
-
Panel viewing window
-
External emergency stop
-
Sound attenuated enclosure, level 2
-
Weatherproof enclosure
-
Sound attenuated enclosure, level 1
-
-
Fuel System
-
5 gallon fill containment
-
Tank riser
-
209 and 394 gallon sub-base fuel tanks
-
Emergency vent pipe
-
5 gallon spill containment
-
-
Mounting System
-
Tests
-
Generator test report
-
PGS test report @ 0.8 power factor
-
4 Hour factory test
-
PGS test report @ 1.0 power factor
-
-
Exhaust System
-
10, 25 and 35 dBA silencer systems
-
Overhead silencer mounting kit
-
-
Generators
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance