C9 Generator Set
Maximum Rating
93.0 hp
330 kVA
Minimum Rating
93.0 hp
230 kVA
Emissions/Fuel Strategy
93.0 hp
EU Stage IIIA
THIS IS MY SELECT
backhoe loader
C9 Generator Set
Maximum Rating
93.0 hp
330 kVA
Minimum Rating
93.0 hp
230 kVA
Emissions/Fuel Strategy
93.0 hp
EU Stage IIIA
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Maximum Rating
93.0 in
93.0 mm
330 kVA
Minimum Rating
93.0 in
93.0 mm
230 kVA
Emissions/Fuel Strategy
93.0 in
93.0 mm
EU Stage IIIA
Voltage
93.0 in
93.0 mm
220 to 480 Volts
Frequency
93.0 in
93.0 mm
50 Hz
Speed
93.0 in
93.0 mm
1500 rpm
Duty Cycle
93.0 in
93.0 mm
Standby, Prime
-
Engine Model
93.0 in
93.0 mm
C9 ATAAC, I-6, 4-Stroke Water-Cooled Diesel
Bore
4.41 in
112 mm
Stroke
5.87 in
149 mm
Displacement
537.01 in³
8.8 l
Compression Ratio
93.0 in
93.0 mm
16.1:1
Aspiration
93.0 in
93.0 mm
Air to Air Aftercooled
Fuel System
93.0 in
93.0 mm
Hydraulic electronic unit injection
Governor Type
93.0 in
93.0 mm
Adem™A4
-
Length - Maximum
157 in
3,988 mm
Width - Maximum
47.5 in
1,207 mm
Height - Maximum
73.5 in
1,867 mm
-
Air Inlet System
-
Control Panels
-
Cooling System
-
Fan drive, battery charging alternator drive
-
Radiator and cooling fan with guard
-
Caterpillar extended life coolant
-
Coolant drain line with valve
-
-
Exhaust System
-
Fuel System
-
Base, formed steel with single wall integral 8-hour fuel tank
-
Standard open set fuel tank / base supplied
-
-
Generators and Generator Attachments
-
12 Leads
-
Mandatory option circuit breaker, IEC, 3 pole mounted in powercentre
-
Voltage regulator (single phase sensing)
-
Segregated low voltage (AC/DC) wiring panel
-
IP23 protection
-
Power centre, IP22
-
-
Governing System
-
Lube System
-
Oil drain valves
-
Lubricating oil
-
Oil cooler
-
-
Mounting System
-
Includes lifting provisions and termination points for coolant and lube oil drain lines
-
Captive linear vibration isolators between base and engine-generator
-
-
Starting / Charging System
-
General
-
Certifications
-
European certificate for conformance
-
Global certificate fpr CIS
-
-
Air inlet system
-
Circuit Breakers
-
Control Panels
-
Control panel protective devices: Earth fault relay ; Earth leakage ground fault ; overload shutdown via breaker ; Low fuel level shutdown ; Low fuel level alarm ; Fuel level sensor
-
Control panel Options: Volt free contacts ; Local alarm horn ; Oil temperature displays
-
-
Cooling System
-
Radiator duct flange
-
Low coolant temperature alarm
-
-
Enclosures
-
Sound attenuated enclosure
-
High ambient sound attenuated enclosure
-
-
Exhaust System
-
5 and 6 inch elbow kits
-
5 - 6 inch flange adaptor
-
Mufflers - End in / End out; 10 dBA or 25 dBA attenuation
-
6 inch flange
-
-
Fuel System
-
Generators and Attachments
-
Permanent magnet generator
-
Oversize, AREP, CIP generators
-
-
Mounting System
-
Starting / Charging System
-
Jacket water heater
-
5 Amp single battery charger
-
Battery disconnet switch
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance