THIS IS MY SELECT

Diesel Generator Sets

D250 GC (60 Hz) Generator Set

Maximum Rating

93.0 hp

250 ekW

Minimum Rating

93.0 hp

250 ekW

Emissions/Fuel Strategy

93.0 hp

EPA Stationary Emergency

THIS IS MY SELECT

backhoe loader

D250 GC (60 Hz) Generator Set

Maximum Rating

93.0 hp

250 ekW

Minimum Rating

93.0 hp

250 ekW

Emissions/Fuel Strategy

93.0 hp

EPA Stationary Emergency

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Maximum Rating

        93.0 in

        93.0 mm

        250 ekW

        Minimum Rating

        93.0 in

        93.0 mm

        250 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        EPA Stationary Emergency

        Voltage

        93.0 in

        93.0 mm

        208 to 600 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby

      • Engine Model

        93.0 in

        93.0 mm

        Cat® C9 In-line 6, 4-cycle Diesel

        Bore

        4.4 in

        112 mm

        Stroke

        5.9 in

        149 mm

        Displacement

        538 in³

        8.8 l

        Compression Ratio

        93.0 in

        93.0 mm

        16.3:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged Air-to-Air Aftercooled

        Fuel System

        93.0 in

        93.0 mm

        HEUI

        Governor Type

        93.0 in

        93.0 mm

        Adem™A4

      • Length - Maximum

        155.5 in

        3,950 mm

        Width - Minimum

        56.3 in

        1,430 mm

        Width - Maximum

        56.7 in

        1,440 mm

        Height - Minimum

        67.2 in

        1,706 mm

        Height - Maximum

        86.7 in

        2,202 mm

        Dry Weight - Genset (minimum)

        5,324.2 lb

        2,415 kg

        Dry Weight - Genset (maximum)

        6,735.1 lb

        3,055 kg

      • Air Inlet System

        • Air cleaner - Non-Canister, Disposable

        • Aftercooler core

        • Turbocharger

      • Control Panel

      • Cooling System

        • Jacket water pump, gear driven, centrifugal

        • Radiator sight gauge

        • Blower fan and fan drive with guards

        • Thermostats and housing.

        • Coolant drain valve.

        • Radiator, Package mounted.

      • Exhaust System

      • Fuel System

        • Fuel priming pump

        • Engine fuel transfer pump

        • Primary fuel filter w/integral water separator and secondary filter, spin on

        • Integral Tank Base, 24 Hrs, UL142

      • Generator Set

        • Factory tested to design specifications at full load conditions

        • Complete system designed & built at ISO 9001:2000 certified facilities

        • All protective devices and control functions simulated and checked

      • Generators and Generator Attachments

        • Easy access to AVR and terminals

        • Insulation, Class H

        • Brushless, self-excited 2/3 pitch (600V uses Internal Excitation)

        • Voltage regulator (single phase sensing)

        • Terminal Box, IP22 RHS Facing, Bottom Cable Entry

        • 12 Leads

        • Standard winding protection for non-harsh environments with relative humidity ? 95%

        • IP23 protection

      • Governing System

      • Lube System

        • Oil filler and dipstick.

        • Lubricating Oil, CK-4 (10W-30)

        • Shallow oil pan.

        • Oil filter, spin on.

        • Fumes disposal to front of radiator.

        • Oil cooler

        • Oil drain with valve.

      • Mounting System

        • Includes lifting provisions and termination points for coolant and lube oil drain lines

        • Captive linear vibration isolators between base and engine-generator

      • Protection

        • Safety Shutoff - Overspeed

        • Safety Shutoff - High water temperature

        • Safety Shutoff - Low Oil Pressure

      • Starting/Charging System

        • 24-volt electric starting motor.

        • 24V, 45 amp charging alternator.

      • General

        • Vibration damper.

        • Lifting Eyes

        • Parts Book

      • Air Inlet System

      • Bases, Mounting & Fuel Tanks

        • Integral Tank Base, 24 Hrs, UL142

        • Audio & Visual Fuel Alarm (@90% Fuel Level)

        • Wide Base - Skid

        • Fuel Tank Fill Pipe & Lockable Cap

      • Circuit Breaker

        • 400A LS/I

        • 600A LS/I

        • 1200A LSI

        • 600A LSI

        • 1200A LS/I

        • Auxiliary Contacts

        • 400A LSI

        • 800A LSI

        • 800A LS/I

      • Control System

        • Twist Release, Red Button Emergency Stop

        • Product Link Remote Monitoring hardware

        • 16 -light NFPA 99/110 Annunciator

        • Volt Free Contacts

        • Ground Fault Relay

        • 20A GFCI (Ground Fault Circuit Interrupter)

        • Audible Alarm Gp

        • 100A Load Center

      • Enclosures

        • E-Stop

        • AC & DC Source Lights

        • Sound Attenuated Level 2 Enclosure (White)

      • Exhaust System

        • 6' Muffler - 25 dBA Attenuation

        • Flexible Exhaust Connection

        • Manifold & Turbocharger Guards

      • Generator

        • Permanent Magnet Generator

        • Space Heater

      • Starting System

        • Standard Battery Set: 1000 CCA, 90 amp/hr.

        • Battery Charger (UL Certified)

        • Jacket Water Heater

      • General

        • CSA Certification

        • Extended Service Coverage

        • Generator Test Report

        • UL2200 Certification

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN