THIS IS MY SELECT

Diesel Generator Sets

D400 GC (60 Hz) Generator Set

Maximum Rating

93.0 hp

400 ekW

Minimum Rating

93.0 hp

400 ekW

Emissions/Fuel Strategy

93.0 hp

EPA Stationary Emergency

THIS IS MY SELECT

backhoe loader

D400 GC (60 Hz) Generator Set

Maximum Rating

93.0 hp

400 ekW

Minimum Rating

93.0 hp

400 ekW

Emissions/Fuel Strategy

93.0 hp

EPA Stationary Emergency

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Maximum Rating

        93.0 in

        93.0 mm

        400 ekW

        Minimum Rating

        93.0 in

        93.0 mm

        400 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        EPA Stationary Emergency

        Voltage

        93.0 in

        93.0 mm

        480 to 600 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby

      • Engine Model

        93.0 in

        93.0 mm

        Cat® C13 In-line 6, 4-cycle diesel

        Bore

        5.1 in

        130 mm

        Stroke

        6.2 in

        157 mm

        Displacement

        763 in³

        12.5 B

        Compression Ratio

        93.0 in

        93.0 mm

        16.3:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged Air-to-Air Aftercooled

        Fuel System

        93.0 in

        93.0 mm

        MEUI

        Governor Type

        93.0 in

        93.0 mm

        ADEM™A4

      • Length - Maximum

        182.8 in

        4,625 mm

        Width - Maximum

        64.2 in

        1,630 mm

        Height - Minimum

        80.3 in

        2,039 mm

        Height - Maximum

        96.7 in

        2,456 mm

        Dry Weight - Genset (minimum)

        7,330.4 lb

        3,325 kg

        Dry Weight - Genset (maximum)

        4,107 lb

        9,054.4 kg

      • Air Inlet System

        • Air cleaner - Non-Canister, Disposable

        • Aftercooler core

        • Turbocharger

      • Control Panel

      • Cooling System

        • Blower fan and fan drive with guards

        • Coolant drain valve.

        • Radiator sight gauge

        • Radiator, Package mounted.

        • Jacket water pump, gear driven, centrifugal

        • Thermostats and housing.

      • Exhaust System

      • Fuel System

        • Primary fuel filter w/integral water separator and secondary filter, spin on

        • Engine fuel transfer pump

        • Fuel cooler

        • Fuel priming pump

        • Integral Tank Base, 24 Hrs, UL142

      • Generator Set

        • All protective devices and control functions simulated and checked

        • Complete system designed & built at ISO 9001:2000 certified facilities

        • Factory tested to design specifications at full load conditions

      • Generators and Generator Attachments

        • Insulation, Class H

        • IP23 protection

        • Standard winding protection for non-harsh environments with relative humidity ? 95%

        • 6 leads

        • Terminal Box, IP22 RHS Facing, Bottom Cable Entry

        • Easy access to AVR and terminals

        • Brushless, self-excited 2/3 pitch (600V uses Internal Excitation)

        • Voltage regulator (single phase sensing)

      • Governing System

      • Lube System

        • Fumes disposal to front of radiator.

        • Lubricating Oil, CK-4 (10W-30)

        • Oil cooler

        • Shallow oil pan.

        • Oil filler and dipstick.

        • Oil filter, spin on.

        • Oil drain with valve.

      • Mounting System

        • Captive linear vibration isolators between base and engine-generator

        • Includes lifting provisions and termination points for coolant and lube oil drain lines

      • Protection

        • Safety Shutoff - Low Oil Pressure

        • Safety Shutoff - High water temperature

        • Safety Shutoff - Overspeed

      • Starting/Charging System

        • 24-volt electric starting motor.

        • 24V,45 amp charging alternator.

      • General

        • Lifting Eyes

        • Vibration damper.

        • Parts Book

      • Air Inlet System

      • Bases, Mounting & Fuel Tanks

        • Audio & Visual Fuel Alarm (@90% Fuel Level)

        • Integral Tank Base, 24 Hrs, UL142

        • 5 gallon Spill Containment

        • Fuel Tank Fill Pipe & Lockable Cap

        • Overfill Prevention Valve

        • Wide Base - Skid

      • Circuit Breaker

        • 1200A LSI

        • 1200A LS/I

        • 600A LS/I

        • 400A LS/I

        • 800A LS/I

        • 600A LSI

        • Auxiliary Contacts

        • 800A LSI

        • 400A LSI

      • Control System

        • Twist Release, Red Button Emergency Stop

        • Ground Fault Relay

        • Volt Free Contacts

        • Audible Alarm Gp

        • 16 -light NFPA 99/110 Annunciator

        • 20A GFCI (Ground Fault Circuit Interrupter)

        • 100A Load Center

        • Product Link Remote Monitoring hardware

      • Enclosures

        • AC & DC Source Lights

        • E-Stop

        • Sound Attenuated Level 2 Enclosure (White)

      • Exhaust System

        • 8' Muffler - 25 dBA Attenuation

        • Manifold & Turbocharger Guards

        • Flexible Exhaust Connection

      • Generator

        • Space Heater

        • Permanent Magnet Generator

      • Circuit Breakers

        • 4 Pole (IEC-100% rated) circuit breaker - Motorised

        • Circuit breaker (IEC) auxiliary contacts

        • Shunt trip for IEC circuit breaker

      • Starting System

        • Oversize Battery Set, 1400 CCA, 200 amp/hr.

        • Standard Battery Set: 1000 CCA, 90 amp/hr.

        • Jacket Water Heater

        • Battery Charger (UL Certified)

      • General

        • Generator Test Report

        • Extended Service Coverage

        • UL2200 Certification

        • CSA Certification

      • starting / Charging System

        • Jacket water heater

        • Battery disconnect switch

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN