THIS IS MY SELECT
Diesel Generator Sets
D450 GC (60 Hz) Generator Set
Maximum Rating
93.0 hp
450 ekW
Minimum Rating
93.0 hp
450 ekW
Emissions/Fuel Strategy
93.0 hp
EPA Stationary Emergency
THIS IS MY SELECT
backhoe loader
D450 GC (60 Hz) Generator Set
Maximum Rating
93.0 hp
450 ekW
Minimum Rating
93.0 hp
450 ekW
Emissions/Fuel Strategy
93.0 hp
EPA Stationary Emergency
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Maximum Rating
93.0 in
93.0 mm
450 ekW
Minimum Rating
93.0 in
93.0 mm
450 ekW
Emissions/Fuel Strategy
93.0 in
93.0 mm
EPA Stationary Emergency
Voltage
93.0 in
93.0 mm
480 to 600 Volts
Frequency
93.0 in
93.0 mm
60 Hz
Speed
93.0 in
93.0 mm
1800 RPM
Duty Cycle
93.0 in
93.0 mm
Standby
-
Engine Model
93.0 in
93.0 mm
Cat® C15 In-line 6, 4-cycle diesel
Bore
5.4 in
137 mm
Stroke
6.8 in
171 mm
Displacement
928 in³
15.2 l
Compression Ratio
93.0 in
93.0 mm
16.1:1
Aspiration
93.0 in
93.0 mm
Turbocharged Air-to-Air Aftercooled
Fuel System
93.0 in
93.0 mm
MEUI
Governor Type
93.0 in
93.0 mm
ADEM™A4
-
Length - Maximum
189.6 in
4,815 mm
Width - Maximum
64.2 in
1,630 mm
Height - Minimum
80.1 in
2,034 mm
Height - Maximum
101.7 in
2,584 mm
Dry Weight - Genset (minimum)
8,172.5 lb
3,707 kg
Dry Weight - Genset (maximum)
10,238.3 lb
4,644 kg
-
Air Inlet System
-
Aftercooler core
-
Turbocharger
-
Air cleaner - Non-Canister, Disposable
-
-
Control Panel
-
Cooling System
-
Thermostats and housing.
-
Blower fan and fan drive with guards
-
Radiator, Package mounted.
-
Coolant drain valve.
-
Jacket water pump, gear driven, centrifugal
-
Radiator sight gauge
-
-
Exhaust System
-
Fuel System
-
Fuel priming pump
-
Integral Tank Base, 24 Hrs, UL142
-
Primary fuel filter w/integral water separator and secondary filter, spin on
-
Engine fuel transfer pump
-
Fuel cooler
-
-
Generator Set
-
Complete system designed & built at ISO 9001:2000 certified facilities
-
Factory tested to design specifications at full load conditions
-
All protective devices and control functions simulated and checked
-
-
Generators and Generator Attachments
-
IP23 protection
-
Voltage regulator (single phase sensing)
-
Easy access to AVR and terminals
-
Brushless, self-excited 2/3 pitch (600V uses Internal Excitation)
-
Terminal Box, IP22 RHS Facing, Bottom Cable Entry
-
Standard winding protection for non-harsh environments with relative humidity ? 95%
-
6 leads
-
Insulation, Class H
-
-
Governing System
-
Lube System
-
Fumes disposal to front of radiator.
-
Oil filter, spin on.
-
Lubricating Oil, CK-4 (10W-30)
-
Shallow oil pan.
-
Oil cooler
-
Oil filler and dipstick.
-
Oil drain with valve.
-
-
Mounting System
-
Includes lifting provisions and termination points for coolant and lube oil drain lines
-
Captive linear vibration isolators between base and engine-generator
-
-
Protection
-
Safety Shutoff - Low Oil Pressure
-
Safety Shutoff - Overspeed
-
Safety Shutoff - High water temperature
-
-
Starting/Charging System
-
24-volt electric starting motor.
-
24V,45 amp charging alternator.
-
-
General
-
Vibration damper.
-
Parts Book
-
Lifting Eyes
-
-
Air Inlet System
-
Bases, Mounting & Fuel Tanks
-
Overfill Prevention Valve
-
Wide Base - Skid
-
Audio & Visual Fuel Alarm (@90% Fuel Level)
-
Integral Tank Base, 24 Hrs, UL142
-
Fuel Tank Fill Pipe & Lockable Cap
-
5 gallon Spill Containment
-
-
Exhaust
-
Circuit Breaker
-
400A LSI
-
400A LS/I
-
800A LSI
-
Auxiliary Contacts
-
600A LS/I
-
1200A LSI
-
600A LSI
-
1200A LS/I
-
800A LS/I
-
-
Control System
-
Volt Free Contacts
-
100A Load Center
-
Product Link Remote Monitoring hardware
-
Twist Release, Red Button Emergency Stop
-
16 -light NFPA 99/110 Annunciator
-
20A GFCI (Ground Fault Circuit Interrupter)
-
Audible Alarm Gp
-
Ground Fault Relay
-
-
Enclosures
-
E-Stop
-
AC & DC Source Lights
-
Sound Attenuated Level 2 Enclosure (White)
-
-
Generator
-
Anti-condensation heater
-
Oversize and premium generators
-
Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
-
Permanent Magnet Generator
-
Space Heater
-
-
Exhaust System
-
Manifold & Turbocharger Guards
-
Flexible Exhaust Connection
-
8' Muffler - 25 dBA Attenuation
-
-
Starting System
-
Standard Battery Set: 1000 CCA, 90 amp/hr.
-
Oversize Battery Set, 1400 CCA, 200 amp/hr.
-
Battery Charger (UL Certified)
-
Jacket Water Heater
-
-
Power Termination
-
Circuit breakers, IEC compliant
-
Circuit breakers, UL listed
-
-
General
-
UL2200 Certification
-
CSA Certification
-
Extended Service Coverage
-
Generator Test Report
-
CSA Certification
-
UL 2200 package
-
-
Lube System
-
Mounting System
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance