THIS IS MY SELECT

Diesel Generator Sets

D50 GC Generator Set

Minimum Rating

93.0 hp

50 ekW

Maximum Rating

93.0 hp

50 ekW

Emissions/Fuel Strategy

93.0 hp

U.S. EPA Cert., Tier 3, SCAQMD Compliant

THIS IS MY SELECT

backhoe loader

D50 GC Generator Set

Minimum Rating

93.0 hp

50 ekW

Maximum Rating

93.0 hp

50 ekW

Emissions/Fuel Strategy

93.0 hp

U.S. EPA Cert., Tier 3, SCAQMD Compliant

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Minimum Rating

        93.0 in

        93.0 mm

        50 ekW

        Maximum Rating

        93.0 in

        93.0 mm

        50 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        U.S. EPA Cert., Tier 3, SCAQMD Compliant

        Voltage

        93.0 in

        93.0 mm

        208 to 600 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby

      • Engine Model

        93.0 in

        93.0 mm

        C4.4, In-line 4, 4-cycle diesel

        Bore

        4.1 in

        105 mm

        Stroke

        5 in

        127 mm

        Displacement

        269 in

        4.4 l

        Compression Ratio

        93.0 in

        93.0 mm

        18.2:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged

        Fuel System

        93.0 in

        93.0 mm

        Common Rail

        Governor Type

        93.0 in

        93.0 mm

        Mechanical, ADEM™A4

      • Length - Maximum

        77.2 in

        1,962 mm

        Width - Maximum

        43.3 in

        1,100 mm

        Height - Maximum

        48 in

        1,220 mm

        Dry Weight - Genset (maximum)

        2,055 lb

        932 kg

      • Certificates

      • Air Inlet System

        • Air Cleaner

        • Cartridge type air filter

      • Circuit Breakers

        • Second circuit breaker box

        • Power perminal strips

        • Breakers (100% UL rated)

        • 3-Pole 100% rated

      • Charging System

      • Control Panel

      • Exhaust System

      • Fuel System

      • Cooling System

        • Fan drive, battery charging alternator drive

        • Caterpillar extended life coolant

        • Radiator and cooling fan with guards

        • Coolant drain line with valve

        • Radiator stone guard

      • Control Panels

        • NFPA110 bundle includes:

        • WCA1 Low coolant temperature alarm

        • FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected

        • WSS1 Low coolant level shut down

        • PBC10NU NFPA Battery Charger

        • Oil temperature guage and sender

        • PAA1 Panel mounted audible alarm

        • A coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application

        • Audible alarm

        • Remote E-stop button

        • Ground fault relay

        • Discrete I/O module

        • Remote annunciator

        • Volt free contacts genset run and common alarm

        • Fuel level reading

        • Protective devices:

        • Low coolant temperature alarm

        • Low coolant level shutdown

        • Overload shutdown via breaker

      • Generator

      • Governing System

      • Lube System

        • Lubricating oil

        • Oil drain line with valve

      • General

      • Starting/Charging System

        • Batteries

        • 24V battery with rack and cables

      • Certificates

      • Air Inlet System

      • Alternator System

      • Charging System

      • Circuit Breakers

        • Breakers (100% UL rated)

        • Power perminal strips

        • 3-Pole 100% rated

        • Second circuit breaker box

      • Control Panels

        • Volt free contacts genset run and common alarm

        • Oil temperature guage and sender

        • Remote E-stop button

        • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker

        • Audible alarm

        • Remote annunciator

        • Discrete I/O module

        • NFPA110 bundle includes: FSS low fuel level alarm & indication panel circuitry required when sub-base tank is selected - WSS1 Low Coolant level shut down - WCA1 Low Coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA Battery Charger - A coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application

        • Ground fault relay

      • Cooling System

      • Enclosures

        • External emergency stop

        • Sound attenuated enclosure, level 2

        • Panel viewing window

      • Exhaust System

        • 10, 25 and 35 dBA silencer systems

        • Overhead silencer mounting kit

      • Fuel System

        • 5 gallon spill containment

        • 209 and 394 gallon sub-base fuel tanks

        • Tank riser

        • Emergency vent pipe

        • 5 gallon fill containment

      • Heating Elements

        • Coolant heater

        • Wiring for canopy space heater

        • Battery heater

        • Lube oil sump heater

        • Anti-condensation heater

        • Wiring for canopy space heater

        • Jacket water heater

      • Generators

        • Permanent magnet generator

        • Permanent magnet generator

      • Mounting System

      • Tests

        • 4 Hour factory test

        • PGS test report @ 1.0 power factor

        • PGS test report @ 0.8 power factor

        • Generator test report

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN