THIS IS MY SELECT
Diesel Generator Sets
D500 GC (60 Hz) Generator Set
Maximum Rating
93.0 hp
500 ekW
Minimum Rating
93.0 hp
500 ekW
Emissions/Fuel Strategy
93.0 hp
EPA Stationary Emergency
THIS IS MY SELECT
backhoe loader
D500 GC (60 Hz) Generator Set
Maximum Rating
93.0 hp
500 ekW
Minimum Rating
93.0 hp
500 ekW
Emissions/Fuel Strategy
93.0 hp
EPA Stationary Emergency
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Maximum Rating
93.0 in
93.0 mm
500 ekW
Minimum Rating
93.0 in
93.0 mm
500 ekW
Emissions/Fuel Strategy
93.0 in
93.0 mm
EPA Stationary Emergency
Voltage
93.0 in
93.0 mm
480 to 600 Volts
Frequency
93.0 in
93.0 mm
60 Hz
Speed
93.0 in
93.0 mm
1800 RPM
Duty Cycle
93.0 in
93.0 mm
Standby
-
Engine Model
93.0 in
93.0 mm
Cat® C15 In-line 6, 4-cycle diesel
Bore
5.4 in
137 mm
Stroke
6.8 in
171 mm
Displacement
928 in³
15.2 l
Compression Ratio
93.0 in
93.0 mm
16.1:1
Aspiration
93.0 in
93.0 mm
Turbocharged Air-to-Air Aftercooled
Fuel System
93.0 in
93.0 mm
MEUI
Governor Type
93.0 in
93.0 mm
ADEM™A4
-
Length - Maximum
189.6 in
4,815 mm
Width - Maximum
64.2 in
1,630 mm
Height - Minimum
2,034 in
80.1 mm
Height - Maximum
101.7 in
2,584 mm
Dry Weight - Genset (minimum)
8,280.6 lb
3,756 kg
Dry Weight - Genset (maximum)
10,346.3 lb
4,693 kg
-
Air Inlet System
-
Air cleaner - Non-Canister, Disposable
-
Turbocharger
-
Aftercooler core
-
-
Control Panel
-
Cooling System
-
Blower fan and fan drive with guards
-
Jacket water pump, gear driven, centrifugal
-
Radiator sight gauge
-
Coolant drain valve.
-
Thermostats and housing.
-
Radiator, Package mounted.
-
-
Exhaust System
-
Fuel System
-
Engine fuel transfer pump
-
Primary fuel filter w/integral water separator and secondary filter, spin on
-
Integral Tank Base, 24 Hrs, UL142
-
Fuel cooler
-
Fuel priming pump
-
-
Generator Set
-
All protective devices and control functions simulated and checked
-
Factory tested to design specifications at full load conditions
-
Complete system designed & built at ISO 9001:2000 certified facilities
-
-
Generators and Generator Attachments
-
Easy access to AVR and terminals
-
Standard winding protection for non-harsh environments with relative humidity ? 95%
-
IP23 protection
-
6 leads
-
Brushless, self-excited 2/3 pitch (600V uses Internal Excitation)
-
Terminal Box, IP22 RHS Facing, Bottom Cable Entry
-
Voltage regulator (single phase sensing)
-
Insulation, Class H
-
-
Governing System
-
Lube System
-
Shallow oil pan.
-
Oil filter, spin on.
-
Oil drain with valve.
-
Lubricating Oil, CK-4 (10W-30)
-
Oil cooler
-
Oil filler and dipstick.
-
Fumes disposal to front of radiator.
-
-
Mounting System
-
Captive linear vibration isolators between base and engine-generator
-
Includes lifting provisions and termination points for coolant and lube oil drain lines
-
-
Protection
-
Safety Shutoff - High water temperature
-
Safety Shutoff - Overspeed
-
Safety Shutoff - Low Oil Pressure
-
-
Starting/Charging System
-
24V,45 amp charging alternator.
-
24-volt electric starting motor.
-
-
General
-
Lifting Eyes
-
Vibration damper.
-
Parts Book
-
-
Air Inlet System
-
Bases, Mounting & Fuel Tanks
-
Audio & Visual Fuel Alarm (@90% Fuel Level)
-
Wide Base - Skid
-
5 gallon Spill Containment
-
Fuel Tank Fill Pipe & Lockable Cap
-
Overfill Prevention Valve
-
Integral Tank Base, 24 Hrs, UL142
-
-
Exhaust
-
Circuit Breaker
-
Auxiliary Contacts
-
600A LSI
-
600A LS/I
-
1200A LSI
-
1200A LS/I
-
400A LSI
-
800A LSI
-
800A LS/I
-
400A LS/I
-
-
Control System
-
Twist Release, Red Button Emergency Stop
-
Ground Fault Relay
-
20A GFCI (Ground Fault Circuit Interrupter)
-
Volt Free Contacts
-
Product Link Remote Monitoring hardware
-
Audible Alarm Gp
-
16 -light NFPA 99/110 Annunciator
-
100A Load Center
-
-
Enclosures
-
E-Stop
-
AC & DC Source Lights
-
Sound Attenuated Level 2 Enclosure (White)
-
-
Exhaust System
-
Manifold & Turbocharger Guards
-
8' Muffler - 25 dBA Attenuation
-
Flexible Exhaust Connection
-
-
Generator
-
Anti-condensation heater
-
Oversize and premium generators
-
Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
-
Permanent Magnet Generator
-
Space Heater
-
-
Starting System
-
Jacket Water Heater
-
Battery Charger (UL Certified)
-
Oversize Battery Set, 1400 CCA, 200 amp/hr.
-
Standard Battery Set: 1000 CCA, 90 amp/hr.
-
-
Power Termination
-
Circuit breakers, UL listed
-
Circuit breakers, IEC compliant
-
-
General
-
CSA Certification
-
Extended Service Coverage
-
Generator Test Report
-
UL2200 Certification
-
CSA Certification
-
UL 2200 package
-
-
Lube System
-
Mounting System
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance