Diesel Generator Sets

D600 GC (60 Hz) Generator Set

Maximum Rating

93.0 hp

600 ekW

Minimum Rating

93.0 hp

600 ekW

Emissions/Fuel Strategy

93.0 hp

EPA Stationary Emergency

THIS IS MY SELECT

backhoe loader

D600 GC (60 Hz) Generator Set

Maximum Rating

93.0 hp

600 ekW

Minimum Rating

93.0 hp

600 ekW

Emissions/Fuel Strategy

93.0 hp

EPA Stationary Emergency

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Maximum Rating

        93.0 in

        93.0 mm

        600 ekW

        Minimum Rating

        93.0 in

        93.0 mm

        600 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        EPA Stationary Emergency

        Voltage

        93.0 in

        93.0 mm

        480 to 600 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby

      • Engine Model

        93.0 in

        93.0 mm

        Cat® C18 In-line 6, 4-cycle Diesel

        Bore

        5.7 in

        145 mm

        Stroke

        7.2 in

        183 mm

        Displacement

        1,106 in³

        18.1 l

        Compression Ratio

        93.0 in

        93.0 mm

        14.5:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged Air-to-Air Aftercooled

        Fuel System

        93.0 in

        93.0 mm

        MEUI

        Governor Type

        93.0 in

        93.0 mm

        ADEM™A4

      • Length - Maximum

        196.1 in

        4,980 mm

        Width - Maximum

        73.4 in

        1,865 mm

        Height - Minimum

        79.1 in

        2,009 mm

        Height - Maximum

        100.9 in

        2,563 mm

        Dry Weight - Genset (minimum)

        8,959.6 lb

        4,064 kg

        Dry Weight - Genset (maximum)

        11,647 lb

        5,283 kg

      • Air Inlet System

        • Turbocharger

        • Air cleaner - Non-Canister, Disposable

        • Aftercooler core

      • Control Panel

      • Cooling System

        • Radiator sight gauge

        • Thermostats and housing.

        • Coolant drain valve.

        • Jacket water pump, gear driven, centrifugal

        • Blower fan and fan drive with guards

        • Radiator, Package mounted.

      • Exhaust System

      • Fuel System

        • Fuel cooler

        • Primary fuel filter w/integral water separator and secondary filter, spin on

        • Integral Tank Base, 24 Hrs, UL142

        • Engine fuel transfer pump

        • Fuel priming pump

      • Generator Set

        • Complete system designed & built at ISO 9001:2000 certified facilities

        • Factory tested to design specifications at full load conditions

        • All protective devices and control functions simulated and checked

      • Generators and Generator Attachments

        • 6 leads

        • Voltage regulator (single phase sensing)

        • Easy access to AVR and terminals

        • Insulation, Class H

        • Brushless, self-excited 2/3 pitch (600V uses Internal Excitation)

        • Terminal Box, IP22 RHS Facing, Bottom Cable Entry

        • Standard winding protection for non-harsh environments with relative humidity ? 95%

        • IP23 protection

      • Governing System

      • Lube System

        • Oil filler and dipstick.

        • Shallow oil pan.

        • Oil filter, spin on.

        • Oil cooler

        • Lubricating Oil, CK-4 (10W-30)

        • Oil drain with valve.

        • Fumes disposal to front of radiator.

      • Mounting System

        • Includes lifting provisions and termination points for coolant and lube oil drain lines

        • Captive linear vibration isolators between base and engine-generator

      • Protection

        • Safety Shutoff - High water temperature

        • Safety Shutoff - Overspeed

        • Safety Shutoff - Low Oil Pressure

      • Starting/Charging System

        • 24V,45 amp charging alternator.

        • 24-volt electric starting motor.

      • General

        • Parts Book

        • Vibration damper.

        • Lifting Eyes

      • Air Inlet System

      • Bases, Mounting & Fuel Tanks

        • Audio & Visual Fuel Alarm (@90% Fuel Level)

        • Integral Tank Base, 24 Hrs, UL142

        • 5 gallon Spill Containment

        • Overfill Prevention Valve

        • Fuel Tank Fill Pipe & Lockable Cap

        • Wide Base - Skid

      • Circuit Breaker

        • 400A LSI

        • Auxiliary Contacts

        • 400A LS/I

        • 800A LSI

        • 600A LSI

        • 1200A LS/I

        • 800A LS/I

        • 600A LS/I

        • 1200A LSI

      • Control System

        • 20A GFCI (Ground Fault Circuit Interrupter)

        • Ground Fault Relay

        • 16 -light NFPA 99/110 Annunciator

        • Volt Free Contacts

        • Twist Release, Red Button Emergency Stop

        • 100A Load Center

        • Product Link Remote Monitoring hardware

        • Audible Alarm Gp

        • Earth (Ground) fault relay

        • Volt free contact

        • Remote E-Stop button

        • Discrete I/O module

        • Annunciators box

        • Local annunciator

      • Exhaust System

        • 8' Muffler - 25 dBA Attenuation

        • Flexible Exhaust Connection

        • Manifold & Turbocharger Guards

      • Generator

        • Space Heater

        • Permanent Magnet Generator

      • Starting System

        • Jacket Water Heater

        • Standard Battery Set: 1000 CCA, 90 amp/hr.

        • Battery Charger (UL Certified)

        • Oversize Battery Set, 1400 CCA, 200 amp/hr.

      • General

        • Extended Service Coverage

        • Generator Test Report

        • CSA Certification

        • UL2200 Certification

        • Tool set

      • Circuit Breakers

        • Single LSI motorised circuit breaker

        • Single LSI motorised Circuit Breaker

        • Auxiliary contacts

        • Neutral bar (208V)

      • Enclosures

        • E-Stop

        • Sound Attenuated Level 2 Enclosure (White)

        • AC & DC Source Lights

        • Sound attenuated enclosure

      • Cooling System

        • Coolant heater

        • Stone guards

        • Jacket water heater with pump

      • Base / Fuel Tank

      • Fuel System

      • Starting and Charging

        • Oversize battery set

        • Standard battery set

        • 5 Amp battery charger

        • Battery disconnect switch

      • Certifications

        • CSA 22.2

        • UL2200 Listed

        • Seismic

      • Lube System

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN