THIS IS MY SELECT
Diesel Generator Sets
DE150 GC Generator Set (50 Hz)
Maximum Rating
93.0 hp
150 kVA
Minimum Rating
93.0 hp
150 kVA
Emissions/Fuel Strategy
93.0 hp
Non Regulated
THIS IS MY SELECT
backhoe loader
DE150 GC Generator Set (50 Hz)
Maximum Rating
93.0 hp
150 kVA
Minimum Rating
93.0 hp
150 kVA
Emissions/Fuel Strategy
93.0 hp
Non Regulated
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Maximum Rating
93.0 in
93.0 mm
150 kVA
Minimum Rating
93.0 in
93.0 mm
150 kVA
Emissions/Fuel Strategy
93.0 in
93.0 mm
Non Regulated
Voltage
93.0 in
93.0 mm
380 to 415 Volts
Frequency
93.0 in
93.0 mm
50 Hz
Speed
93.0 in
93.0 mm
1500 rpm
Duty Cycle
93.0 in
93.0 mm
Standby
-
Engine Model
93.0 in
93.0 mm
C7.1 I-6, 4-Cycle Diesel
Bore
4.1 in
105 mm
Stroke
5.3 in
135 mm
Displacement
427.8 in³
7 l
Compression Ratio
93.0 in
93.0 mm
18.2:1
Aspiration
93.0 in
93.0 mm
Turbocharged
Fuel System
93.0 in
93.0 mm
Inline
Governor Type
93.0 in
93.0 mm
Mechanical
-
Length - Maximum
130.9 in
3,325 mm
Width - Maximum
44.6 in
1,134 mm
Height - Maximum
65.6 in
1,666 mm
Dry Weight - Genset (maximum)
4,043 lb
1,834 kg
-
Engine
-
Control Panels
-
Enclosure
-
Governor
-
Fuel Storage
-
Alternator
-
Air, Cooling & Exhaust
-
General
-
Certification
-
Certificate of Conformance
-
Australia, CIS, Gulf Certification
-
-
Auxiliary Supply Voltage
-
Alternator Requirements
-
Genset Control
-
Volt Free Contacts for Common Alarm
-
Battery Charger
-
Panel Mounted Audible Alarm
-
Volt Free Contacts for Genset Running
-
Earth Leakage
-
Earth Fault
-
Emergency Stop with Key
-
USB to RS485 Communications Device
-
Coolant Heater
-
Battery
-
Low Coolant Level Shutdown
-
-
Fuel Storage
-
Dual Wall 8 Hour Tank
-
Low Fuel Level Shutdown
-
Low Fuel Level Alarm
-
Single Wall Tank With Containment
-
High Fuel Level Alarm
-
-
Circuit Breaker
-
3 Pole Circuit Breaker 630A
-
4 Pole Circuit Breaker 250A
-
4 Pole Circuit Breaker 200A
-
3 Pole Circuit Breaker 200A
-
3 Pole Circuit Breaker 250A
-
4 Pole Circuit Breaker 400A
-
4 Pole Circuit Breaker 630A
-
Circuit Breaker Padlock
-
Neutral Earth Link
-
Overload via Alarm Switch on Breaker
-
3 Pole Circuit Breaker 400A
-
-
Testing & Packaging
-
PGS Test Report @ 1.0PF
-
PGS Test Report @ 0.8PF
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance