THIS IS MY SELECT

Diesel Generator Sets

DE150 GC Generator Set (60 Hz)

Minimum Rating

93.0 hp

132 ekW

Maximum Rating

93.0 hp

132 ekW

Emissions/Fuel Strategy

93.0 hp

Non Regulated

THIS IS MY SELECT

backhoe loader

DE150 GC Generator Set (60 Hz)

Minimum Rating

93.0 hp

132 ekW

Maximum Rating

93.0 hp

132 ekW

Emissions/Fuel Strategy

93.0 hp

Non Regulated

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Minimum Rating

        93.0 in

        93.0 mm

        132 ekW

        Maximum Rating

        93.0 in

        93.0 mm

        132 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Non Regulated

        Voltage

        93.0 in

        93.0 mm

        220 to 480 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby

      • Engine Model

        93.0 in

        93.0 mm

        C7.1 I-6, 4-Cycle Diesel

        Bore

        4.1 in

        105 mm

        Stroke

        5.3 in

        135 mm

        Displacement

        427.8 in³

        7 l

        Compression Ratio

        93.0 in

        93.0 mm

        18.2:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged

        Fuel System

        93.0 in

        93.0 mm

        Inline

        Governor Type

        93.0 in

        93.0 mm

        Mechanical

      • Length - Maximum

        130.9 in

        3,325 mm

        Width - Maximum

        44.6 in

        1,134 mm

        Height - Maximum

        65.6 in

        1,666 mm

        Dry Weight - Genset (maximum)

        4,043 lb

        1,834 kg

      • Engine

      • Control Panels

      • Fuel Storage

      • Governor

      • Enclosure

      • Alternator

      • Air, Cooling & Exhaust

      • General

      • Auxiliary Supply Voltage

      • Certification

        • Certificate of Conformance

        • Australia, CIS, Gulf Certification

      • Alternator Requirements

      • Fuel Storage

        • Dual Wall 8 Hour Tank

        • Low Fuel Level Alarm

        • High Fuel Level Alarm

        • Low Fuel Level Shutdown

        • Single Wall Tank With Containment

      • Circuit Breaker

        • 3 Pole Circuit Breaker 630A

        • 4 Pole Circuit Breaker 250A

        • 4 Pole Circuit Breaker 200A

        • 3 Pole Circuit Breaker 250A

        • 3 Pole Circuit Breaker 200A

        • 4 Pole Circuit Breaker 400A

        • 4 Pole Circuit Breaker 630A

        • Circuit Breaker Padlock

        • Neutral Earth Link

        • Overload via Alarm Switch on Breaker

        • 3 Pole Circuit Breaker 400A

      • Genset Control

        • Panel Mounted Audible Alarm

        • Battery Charger

        • Earth Leakage

        • Volt Free Contacts for Genset Running

        • Volt Free Contacts for Common Alarm

        • Earth Fault

        • Emergency Stop with Key

        • USB to RS485 Communications Device

        • Coolant Heater

        • Battery

        • Low Coolant Level Shutdown

        • Standby Pack (Smart Jacket Water Heater, Battery Charger)

      • Testing & Packaging

        • PGS Test Report @ 1.0PF

        • PGS Test Report @ 0.8PF

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN