THIS IS MY SELECT
Diesel Generator Sets
DE200 GC Generator Set (50 Hz)
Maximum Rating
93.0 hp
200 kVA
Minimum Rating
93.0 hp
200 kVA
Emissions/Fuel Strategy
93.0 hp
Non Regulated
THIS IS MY SELECT
backhoe loader
DE200 GC Generator Set (50 Hz)
Maximum Rating
93.0 hp
200 kVA
Minimum Rating
93.0 hp
200 kVA
Emissions/Fuel Strategy
93.0 hp
Non Regulated
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Maximum Rating
93.0 in
93.0 mm
200 kVA
Minimum Rating
93.0 in
93.0 mm
200 kVA
Emissions/Fuel Strategy
93.0 in
93.0 mm
Non Regulated
Voltage
93.0 in
93.0 mm
380 to 415 Volts
Frequency
93.0 in
93.0 mm
50 Hz
Speed
93.0 in
93.0 mm
1500 rpm
Duty Cycle
93.0 in
93.0 mm
Standby
-
Engine Model
93.0 in
93.0 mm
C7.1 I-6, 4-Cycle Diesel
Bore
4.1 in
105 mm
Stroke
5.3 in
135 mm
Displacement
427.8 in³
7 l
Compression Ratio
93.0 in
93.0 mm
16.0:1
Aspiration
93.0 in
93.0 mm
Turbocharged Air To Air Charge Cooled
Fuel System
93.0 in
93.0 mm
Inline
Governor Type
93.0 in
93.0 mm
Mechanical
-
Length - Maximum
130.9 in
3,325 mm
Width - Maximum
44.6 in
1,134 mm
Height - Maximum
65.6 in
1,666 mm
Dry Weight - Genset (maximum)
4,257 lb
1,931 kg
-
Engine
-
Control Panels
-
Enclosure
-
Fuel Storage
-
Alternator
-
Governor
-
Air, Cooling & Exhaust
-
General
-
Auxiliary Supply Voltage
-
Certification
-
Certificate of Conformance
-
Australia, CIS, Gulf Certification
-
-
Alternator Requirements
-
Fuel Storage
-
Dual Wall 8 Hour Tank
-
Single Wall Tank With Containment
-
Low Fuel Level Alarm
-
Low Fuel Level Shutdown
-
High Fuel Level Alarm
-
-
Genset Control
-
Panel Mounted Audible Alarm
-
Volt Free Contacts for Genset Running
-
Volt Free Contacts for Common Alarm
-
Battery Charger
-
Earth Leakage
-
USB to RS485 Communications Device
-
Emergency Stop with Key
-
Earth Fault
-
Coolant Heater
-
Low Coolant Level Shutdown
-
Battery
-
Standby Pack (Smart Jacket Water Heater, Battery Charger)
-
-
Circuit Breaker
-
4 Pole Circuit Breaker 200A
-
4 Pole Circuit Breaker 250A
-
3 Pole Circuit Breaker 630A
-
3 Pole Circuit Breaker 200A
-
3 Pole Circuit Breaker 250A
-
4 Pole Circuit Breaker 400A
-
4 Pole Circuit Breaker 630A
-
Circuit Breaker Padlock
-
Neutral Earth Link
-
Overload via Alarm Switch on Breaker
-
3 Pole Circuit Breaker 400A
-
-
Testing & Packaging
-
PGS Test Report @ 1.0PF
-
PGS Test Report @ 0.8PF
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance