THIS IS MY SELECT

Diesel Generator Sets

DE50 GC Generator Set (50 Hz)

Minimum Rating

93.0 hp

50.0 kVA

Maximum Rating

93.0 hp

50.0 kVA

Emissions/Fuel Strategy

93.0 hp

Non Regulated

THIS IS MY SELECT

backhoe loader

DE50 GC Generator Set (50 Hz)

Minimum Rating

93.0 hp

50.0 kVA

Maximum Rating

93.0 hp

50.0 kVA

Emissions/Fuel Strategy

93.0 hp

Non Regulated

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Minimum Rating

        93.0 in

        93.0 mm

        50.0 kVA

        Maximum Rating

        93.0 in

        93.0 mm

        50.0 kVA

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Non Regulated

        Voltage

        93.0 in

        93.0 mm

        380 to 415 Volts

        Frequency

        93.0 in

        93.0 mm

        50 Hz

        Speed

        93.0 in

        93.0 mm

        1500 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby

      • Engine Model

        93.0 in

        93.0 mm

        Cat® C3.3, In-line 3, 4-cycle diesel

        Bore

        4.1 in

        105 mm

        Stroke

        5 in

        127 mm

        Displacement

        201.4 in³

        3.3 l

        Compression Ratio

        93.0 in

        93.0 mm

        17.25:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged

        Fuel System

        93.0 in

        93.0 mm

        Inline

        Governor Type

        93.0 in

        93.0 mm

        Mechanical

      • Length - Maximum

        89.7 in

        2,278 mm

        Width - Maximum

        35.4 in

        900 mm

        Height - Maximum

        52 in

        1,322 mm

        Dry Weight - Genset (maximum)

        2,273 lb

        1,031 kg

      • Engine

      • Genset Control

      • Governor

      • Alternator

      • Fuel Storage

      • Enclosure

      • Air, Cooling & Exhaust

      • General

      • Certification

        • Certificate of Conformance

        • Australia, CIS, Gulf Certification

      • Alternator Requirements

      • Auxiliary Supply Voltage

      • Fuel Storage

        • Dual wall 8 hour tank

        • Single wall tank with containment

        • Low fuel level alarm

        • Low fuel level shutdown

        • High fuel level alarm

      • Genset Control

        • Battery charger

        • Volt free contacts for genset running

        • Volt free contacts for common alarm

        • Earth leakage

        • Earth fault

        • Emergency stop with key

        • USB to RS485 communications device

        • Panel mounted audible alarm

        • Battery

        • Low coolant level shutdown

        • Standby Pack (Smart jacket water heater, battery charger)

        • Coolant heater

      • Circuit Breaker

        • 3 Pole circuit breaker 80A

        • 3 Pole circuit breaker 63A

        • 3 Pole circuit breaker 100A

        • 3 Pole circuit breaker 125A

        • 3 Pole circuit breaker 160A

        • 3 Pole circuit breaker 200A

        • 4 Pole circuit breaker 80A

        • 4 Pole circuit breaker 63A

        • 4 Pole circuit breaker 100A

        • 4 Pole circuit breaker 125A

        • 4 Pole circuit breaker 160A

        • 4 Pole circuit breaker 200A

        • Circuit breaker padlock

        • Neutral earth link

        • Overload via alarm switch on breaker

      • Testing & Packaging

        • PGS Test Report @ 1.0PF

        • PGS Test Report @ 0.8PF

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN