THIS IS MY SELECT
Diesel Generator Sets
DE65 GC Generator Set (50 Hz)
Maximum Rating
93.0 hp
65.0 kVA
Minimum Rating
93.0 hp
65.0 kVA
Emissions/Fuel Strategy
93.0 hp
Non Regulated
THIS IS MY SELECT
backhoe loader
DE65 GC Generator Set (50 Hz)
Maximum Rating
93.0 hp
65.0 kVA
Minimum Rating
93.0 hp
65.0 kVA
Emissions/Fuel Strategy
93.0 hp
Non Regulated
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Maximum Rating
93.0 in
93.0 mm
65.0 kVA
Minimum Rating
93.0 in
93.0 mm
65.0 kVA
Emissions/Fuel Strategy
93.0 in
93.0 mm
Non Regulated
Voltage
93.0 in
93.0 mm
380 to 415 Volts
Frequency
93.0 in
93.0 mm
50 Hz
Speed
93.0 in
93.0 mm
1500 rpm
Duty Cycle
93.0 in
93.0 mm
Standby
-
Engine Model
93.0 in
93.0 mm
Cat® C3.3, In-line 3, 4-cycle diesel
Bore
4.1 in
105 mm
Stroke
5 in
127 mm
Displacement
201.4 in³
3.3 l
Compression Ratio
93.0 in
93.0 mm
17.25:1
Aspiration
93.0 in
93.0 mm
Turbocharged
Fuel System
93.0 in
93.0 mm
Inline
Governor Type
93.0 in
93.0 mm
Mechanical
-
Length - Maximum
89.7 in
2,278 mm
Width - Maximum
35.4 in
900 mm
Height - Maximum
52 in
1,322 mm
Dry Weight - Genset (maximum)
2,273 lb
1,031 kg
-
Engine
-
Genset Control
-
Governor
-
Alternator
-
Fuel Storage
-
Enclosure
-
Air, Cooling & Exhaust
-
General
-
Certification
-
Certificate of Conformance
-
Australia, CIS, Gulf Certification
-
-
Alternator Requirements
-
Auxiliary Supply Voltage
-
Fuel Storage
-
Dual wall 8 hour tank
-
Single wall tank with containment
-
Low fuel level alarm
-
Low fuel level shutdown
-
High fuel level alarm
-
-
Genset Control
-
Battery charger
-
Volt free contacts for common alarm
-
Volt free contacts for genset running
-
Panel mounted audible alarm
-
Earth fault
-
Earth leakage
-
USB to RS485 communications device
-
Emergency stop with key
-
Battery
-
Standby Pack (Smart jacket water heater, battery charger)
-
Coolant heater
-
Low coolant level shutdown
-
-
Circuit Breaker
-
3 Pole circuit breaker 63A
-
3 Pole circuit breaker 80A
-
3 Pole circuit breaker 100A
-
3 Pole circuit breaker 125A
-
3 Pole circuit breaker 160A
-
3 Pole circuit breaker 200A
-
4 Pole circuit breaker 80A
-
4 Pole circuit breaker 63A
-
4 Pole circuit breaker 100A
-
4 Pole circuit breaker 125A
-
4 Pole circuit breaker 160A
-
4 Pole circuit breaker 200A
-
Circuit breaker padlock
-
Neutral earth link
-
Overload via alarm switch on breaker
-
-
Testing & Packaging
-
PGS Test Report @ 1.0 power factor
-
PGS Test Report @ 0.8 power factor
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance