THIS IS MY SELECT
Diesel Generator Sets
DE660 GC (50 Hz) Generator Set
Maximum Rating
93.0 hp
660 kVA
Minimum Rating
93.0 hp
660 kVA
Emissions/Fuel Strategy
93.0 hp
Non Regulated
THIS IS MY SELECT
backhoe loader
DE660 GC (50 Hz) Generator Set
Maximum Rating
93.0 hp
660 kVA
Minimum Rating
93.0 hp
660 kVA
Emissions/Fuel Strategy
93.0 hp
Non Regulated
Specifications
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
-
Maximum Rating
93.0 in
93.0 mm
660 kVA
Minimum Rating
93.0 in
93.0 mm
660 kVA
Emissions/Fuel Strategy
93.0 in
93.0 mm
Non Regulated
Voltage
93.0 in
93.0 mm
380 to 415 Volts
Frequency
93.0 in
93.0 mm
50 Hz
Speed
93.0 in
93.0 mm
1500 rpm
Duty Cycle
93.0 in
93.0 mm
Standby
-
Engine Model
93.0 in
93.0 mm
C15 In-line 6, 4-cycle diesel
Bore
5.4 in
137 mm
Stroke
6.8 in
171 mm
Displacement
928 in³
15.2 l
Compression Ratio
93.0 in
93.0 mm
16.1:1
Aspiration
93.0 in
93.0 mm
Turbocharged Air-to-Air Aftercooled
Fuel System
93.0 in
93.0 mm
EUI
Governor Type
93.0 in
93.0 mm
Adem™A4
-
Length - Maximum
131 in
3,328 mm
Width - Maximum
60.6 in
1,540 mm
Height - Maximum
86.1 in
2,187 mm
Dry Weight - Genset (maximum)
8,364 lb
3,794 kg
-
Engine
-
Air Inlet
-
Control Panels
-
Governor
-
Cooling
-
Alternator
-
Fuel Storage
-
Cooling System
-
Radiator and cooling fan with guards
-
Fan drive, battery charging alternator drive
-
-
Fuel
-
Fuel priming pump
-
Primary fuel filter with integral water separator
-
Secondary fuel filter
-
-
Electrical Options
-
3 Pole Circuit Breaker
-
Neutral Earth Link
-
24 Volt battery with rack and cables
-
-
Air inlet system
-
Generator
-
Matched to the performance and output characteristics of Cat engines
-
Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
-
IP23 Protection
-
-
Lube system
-
Lubricating oil
-
Oil drain line with valve
-
-
Mounting system
-
Captive linear vibration isolators
-
Lifting provision and drag points
-
-
General
-
Engine and alternator pre paint, Caterpillar yellow
-
Engine and alternator pre paint, Caterpillar yellow
-
-
Power Termination
-
Generator and Attachments
-
Power center, IP22
-
Segregated low voltage (AC/DC) wiring panel
-
Optional LC frame generator - IP23 Protection
-
Integrated Voltage Regulator
-
Mandatory Option circuit breaker, IEC, 3 pole, mounted in power centre
-
-
Mounting
-
Governing System
-
Lube System
-
Oil cooler
-
Oil drain valves
-
-
Mounting System
-
Control panel
-
PLG 4G/3G/Ethernet
-
Annunciator
-
Emergency E-Stop
-
-
Exhaust
-
Enclosure
-
Generator
-
Oversize and premium generators
-
Excitation: [ ] Permanent Magnet Excited (PM) [ ] Internally Excited (IE)
-
Anti-condensation heater
-
-
Electrical Options
-
4 Pole circuit breaker
-
Auxiliary Contacts
-
Pad-lockable circuit breaker
-
Battery Charger
-
Wet Battery
-
-
Power Termination
-
Circuit breakers, UL listed
-
Circuit breakers, IEC compliant
-
-
Alternator
-
Space Heater
-
AVR
-
-
Generator and Attachments
-
Oversize A frame generator
-
LC frame generator
-
LC frame CIP generator
-
Ingress protection
-
CIP a frame generator
-
Permanent magnet generator
-
Oversize LC frame generator
-
Space heaters
-
-
Starting/Charging
-
Oversize batteries
-
Charging alternator
-
Jacket water heater
-
Battery chargers
-
Heavy-duty starting system
-
24 Volt battery with rack and cables
-
-
Air inlet system
-
Single Stage Air Filter
-
Dual Element Air Filter
-
-
Certifications
-
EU certificate of conformance
-
EAC certification
-
-
General
-
The following options are based on regional and product configuration:
-
Sound attenuated, weather protective or high ambient weather protective enclosure
-
UL 2200 package
-
CSA Certification
-
Narrow, Wide or Skid Base
-
EEC Declaration of Conformity
-
EU Certificate of Conformance (CE)
-
Single or dual wall sub-base fuel tanks
-
Single or dual wall integral fuel tanks
-
Automatic transfer switches (ATS)
-
Integral & sub-base UL listed dual wall fuel tanks
-
Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
-
-
Extended service coverage
-
Enclosures
-
High ambient sound attenuated enclosures
-
Sound attenuated enclosures
-
-
Exhaust System
-
Industrial Silencer
-
10 dBA Attenuation silencer
-
6 and 8 inch elbow kit
-
Flexible exhaust fittings
-
6 and 8 inch flange GP
-
Manifold and turbocharger guard
-
End in / End out mufflers - 10, 25 and 35 dBA attenuation
-
Engine mounted muffler
-
-
Fuel System
-
Dual Wall 8Hr Fuel Tank
-
Single Wall 8Hr Fuel Tank with Spill Containment
-
Low Fuel Level Shutdown
-
Low and High Fuel Level Alarms
-
Manual fuel transfer pump
-
Dual wall fuel tank base
-
Fuel transfer system controls
-
-
Lube System
-
Mounting System
-
Special Test / Reports
-
PGS Test report @ 1.0 power factor
-
PGS Test report @ 0.8 power factor
-
-
Starting / Charging System
-
5 Amp single battery charger
-
Jacket water heater
-
Battery disconnect switch
-
Similar Models
WHY CHOOSE EMPIRE
-
In-house, local project teams for design, engineering and management
-
Every purchase backed by a full menu of service and support offerings
-
Flexible financing options designed to fit your budget
-
Commitment to providing expert training to maximize operations
-
Value Agreements to ensure proper maintenance and performance