THIS IS MY SELECT

Diesel Generator Sets

DE88 GC Generator Set (60 Hz)

Minimum Rating

93.0 hp

80 ekW

Maximum Rating

93.0 hp

80 ekW

Emissions/Fuel Strategy

93.0 hp

Non Regulated

THIS IS MY SELECT

backhoe loader

DE88 GC Generator Set (60 Hz)

Minimum Rating

93.0 hp

80 ekW

Maximum Rating

93.0 hp

80 ekW

Emissions/Fuel Strategy

93.0 hp

Non Regulated

Specifications

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

      • Minimum Rating

        93.0 in

        93.0 mm

        80 ekW

        Maximum Rating

        93.0 in

        93.0 mm

        80 ekW

        Emissions/Fuel Strategy

        93.0 in

        93.0 mm

        Non Regulated

        Voltage

        93.0 in

        93.0 mm

        220 to 480 Volts

        Frequency

        93.0 in

        93.0 mm

        60 Hz

        Speed

        93.0 in

        93.0 mm

        1800 rpm

        Duty Cycle

        93.0 in

        93.0 mm

        Standby

      • Engine Model

        93.0 in

        93.0 mm

        C4.4, In-line 4, 4-cycle diesel

        Bore

        4.1 in

        105 mm

        Stroke

        5 in

        127 mm

        Displacement

        268.5 in

        4.4 l

        Compression Ratio

        93.0 in

        93.0 mm

        17.25:1

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged

        Fuel System

        93.0 in

        93.0 mm

        Inline

        Governor Type

        93.0 in

        93.0 mm

        Mechanical

      • Length - Maximum

        89.6 in

        2,275 mm

        Width - Maximum

        43.3 in

        1,099 mm

        Height - Maximum

        57.7 in

        1,465 mm

        Dry Weight - Genset (maximum)

        1,245 lb

        2,745 kg

      • Engine

      • Governor

      • Alternator

      • Fuel Storage

      • Genset Control

      • Enclosure

      • Air, Cooling & Exhaust

      • General

      • Auxiliary Supply Voltage

      • Certification

        • Australia, CIS, Gulf Certification

        • Certificate of Conformance

      • Alternator Requirements

      • Fuel Storage

        • Low Fuel Level Shutdown

        • Single Wall Tank With Containment

        • Dual Wall 8 Hour Tank

        • Low Fuel Level Alarm

        • High Fuel Level Alarm

      • Genset Control

        • Volt Free Contacts for Genset Running

        • Earth Fault

        • Panel Mounted Audible Alarm

        • USB to RS485 Communications Device

        • Emergency Stop with Key

        • Earth Leakage

        • Battery Charger

        • Volt Free Contacts for Common Alarm

        • Coolant Heater

        • Standby Pack (Smart Jacket Water Heater, Battery Charger)

        • Battery

        • Low Coolant Level Shutdown

      • Circuit Breaker

        • 3 Pole Circuit Breaker 160A

        • 3 Pole Circuit Breaker 125A

        • 3 Pole Circuit Breaker 200A

        • 3 Pole Circuit Breaker 400A

        • 4 Pole Circuit Breaker 160A

        • 4 Pole Circuit Breaker 125A

        • 3 Pole Circuit Breaker 250A

        • 4 Pole Circuit Breaker 250A

        • 4 Pole Circuit Breaker 200A

        • Circuit Breaker Padlock

        • 4 Pole Circuit Breaker 400A

        • Neutral Earth Link

        • Overload via Alarm Switch on Breaker

      • Testing & Packaging

        • PGS Test Report @ 1.0PF

        • PGS Test Report @ 0.8PF

      Similar Models

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN