Minimum Rating

1,045 ekW

Maximum Rating

1,245 ekW

Emissions

93.0 hp

Non-certified

THIS IS MY SELECT

backhoe loader

3512B Land Electric-Drive Drilling Module

Minimum Rating

1,045 ekW

Maximum Rating

1,245 ekW

Emissions

93.0 hp

Non-certified

Specifications

Oil and gas drilling is a complex task that requires specialized power generation equipment. Cat 3500 power modules are specifically designed for drilling operations of electric AC rigs. They combine decades of field experience of the 3500 platform with the latest electronics to ensure highest performance, low emissions, and simplified operator interface. Cat power modules are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty. 3512B land drilling power module ratings: 1045-1245 ekW (1492-1750 kVA) @ 50/60 Hz (1200/1500 rpm). Not emissions certified, available for non-regulated areas.

      • Minimum Rating

        1,045 ekW

        1,045 ekW

        Maximum Rating

        1,245 ekW

        1,245 ekW

        Emissions

        93.0 in

        93.0 mm

        Non-certified

        Oil Change Interval

        500 h

        500 h

        Bore

        6.69 in

        170 mm

        Fuel System

        93.0 in

        93.0 mm

        EUI

        Engine Control and Protection

        93.0 in

        93.0 mm

        ADEM A3

        Generator

        93.0 in

        93.0 mm

        SR4B

        Displacement

        3,158 in³

        52 l

        Stroke

        7.48 in

        190 mm

        Generator Set Control

        93.0 in

        93.0 mm

        EMCP 4.3

        Weight

        30,864 lb

        14,000 kg

        Voltage

        93.0 in

        93.0 mm

        600

        Aspiration

        93.0 in

        93.0 mm

        Turbocharged-Aftercooled

      • Height

        104.7 in

        2,659 mm

        Width

        91.2 in

        2,318 mm

        Length

        238.2 in

        6,051 mm

      • Cooling System - Engine

        41 gal (US)

        157 l

        Lube Oil System - Refill

        84 gal (US)

        318 l

      • Air Inlet System

        • Corrosion-resistant aftercooler core

        • Air Inlet shutoff

        • Regular duty air cleaner

      • Control System

        • ADEM A3 ECU, left-hand mounted

        • Direct rack control 0-200 mADC, space heater and jacket water heater connection and controls

      • Cooling System

        • Caterpillar supplied radiator, 46/CVS-stacked 0.627 ratio, includes blower fan, fan drive, pulley, belt guard, coolant level sensor, regulator, and fuel cooler

        • Separate-circuit aftercooled

        • Outlet controlled jacket water thermostat

        • Jacket water pump - gear driven

        • Dual outlet

        • Aftercooler water pump - gear driven

        • Aftercooler water thermostat

      • Exhaust System

        • Dry exhaust manifold

        • Dual turbochargers, water cooled bearings

      • Flywheel and Housing

        • SAE No. 00 flywheel

        • SAE No. 00 flywheel housing

        • SAE standard rotation

      • Fuel System

        • Fuel filter simplex (LH) with priming pump (LH)

        • Fuel transfer pump

        • Fuel return line with flexible connection

        • Electronic unit injectors

      • Generator Attachments

      • Instrumentation

        • Emergency stop button

        • Analog gauges:

        • Service port connector

        • Customer connection terminal blocks

      • EMCP 4.3 Control Panel

        • 140 mm (5.5 in) Graphical Display

        • Communication

        • Controls

        • Generator Set Protection

        • Outputs

        • Inputs

        • Other Features

      • Lubrication System

        • Crankcase breather

        • Oil cooler

        • Shallow oil pan

        • Oil drain extension, 2 in NPT female connection

        • Simplex oil filter

      • Mounting System

      • Protection System

      • Starting System

      • General

      • Air Inlet System

        • Heavy duty air cleaner

        • Remote air inlet adapter - rectangular

        • Remote air inlet adapter - round

      • Control System

        • Engine control options:

        • Load sharing governor, 2301A

      • Cooling System

        • Radiator options:

        • Coolant level sensor

        • Coolant conditioner

        • Cooling system connection options (for use with customer-supplied radiator):

        • Fan drive and belt guard (for use with remote and customersupplied radiators)

        • Fan pulley options (for use with customer-supplied radiator):

      • Exhaust System

        • 1200 rpm model only:

        • 1500 rpm model only:

      • Fuel System

        • Custom fuel filter

        • Primary fuel filter

        • Primary fuel filter with water separator

      • Generator Attachments

        • Barrel-mounted petroleum terminal box

        • Current transformers (3)

        • Cable access box

      • Instrumentation

        • Communications module PL1000T

        • Communications module PL1000E

        • Thermocouples installed, one per cylinder

      • Lubrication System

        • Custom oil filter

        • RH installed centrifugal oil filter

        • SAE15W40, Caterpillar DEO, 500 hour

        • Crankcase fumes disposal

        • Oil level regulator

      • Mounting System

        • Custom inner base

        • Custom outer base

        • Package isolator supports (3), for mounting inner base to customer-supplied base

      • Power Take-off

      • Protection System

        • Explosion relief valves (3)

        • Metal particle detector switch

        • Metal particle detector with annunciator

      • Starting System

        • Custom starting motor

        • Air pressure regulator

      • General

        • LH installed engine barring group

        • Jacket water heater, UL recognized, 120-240V, single phase, 6 kW, LH and RH mounted

        • Jacket water heater, UL recognized, 120-480V, single phase, 12 kW, LH and RH mounted

        • Jacket water heater lines

      WHY CHOOSE EMPIRE

      • In-house, local project teams for design, engineering and management

      • Every purchase backed by a full menu of service and support offerings

      • Flexible financing options designed to fit your budget

      • Commitment to providing expert training to maximize operations

      • Value Agreements to ensure proper maintenance and performance

      YOU MIGHT ALSO BE INTERESTED IN