Maximum Rating

110 kVA

Minimum Rating

110 kVA

Emissions/Fuel Strategy

Non Regulated

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C4.4, In-line 4, 4-cycle diesel

    Bore

    4.1 in

    Stroke

    in

    Displacement

    268.5 in

    Compression Ratio

    18.23:1

    Aspiration

    Turbocharged Air To Air Charge Cooled

    Fuel System

    Inline

    Governor Type

    Mechanical

    Generator Set Dimensions

    Length - Maximum

    108.1 in

    Width - Maximum

    39.3 in

    Height - Maximum

    58.1 in

    Dry Weight - Genset (maximum)

    1,330 lb

    Generator Set Specifications

    Maximum Rating

    110 kVA

    Minimum Rating

    110 kVA

    Emissions/Fuel Strategy

    Non Regulated

    Voltage

    380 to 415 Volts

    Frequency

    50 Hz

    Speed

    1500 rpm

    Duty Cycle

    Standby

    • Engine
      • C4.4, Inline 4 Cylinder, 4 Stroke Diesel
    • Genset Control
      • GCCP 1.1
    • Governor
      • Mechanical Governor
    • Fuel Storage
      • Single Wall 8 Hour Tank
    • Alternator
      • A Frame Standard Alternator
    • Enclosure
      • Cat GC Enclosure
    • Air, Cooling & Exhaust
      • Enclosure Silencer
    • General
      • Engine and alternator pre-paint, Caterpillar yellow

    • Certification
      • Certificate of Conformance 13
      • Australia, CIS, Gulf Certification
    • Auxiliary Supply Voltage
      • 120V
    • Alternator Requirements
      • Space Heater
    • Fuel Storage
      • Dual Wall 8 Hour Tank
      • Single Wall Tank With Containment
      • High Fuel Level Alarm
      • Low Fuel Level Alarm
      • Low Fuel Level Shutdown
    • Genset Control
      • Volt Free Contacts for Common Alarm
      • Panel Mounted Audible Alarm
      • Earth Fault
      • Volt Free Contacts for Genset Running
      • Emergency Stop with Key
      • Earth Leakage
      • Battery Charger
      • USB to RS485 Communications Device
      • Coolant Heater
      • Standby Pack (Smart Jacket Water Heater, Battery Charger)
      • Battery
      • Low Coolant Level Shutdown
    • Circuit Breaker
      • 3 Pole Circuit Breaker 125A
      • 3 Pole Circuit Breaker 160A
      • 3 Pole Circuit Breaker 200A
      • 4 Pole Circuit Breaker 125A
      • 3 Pole Circuit Breaker 400A
      • 3 Pole Circuit Breaker 250A
      • 4 Pole Circuit Breaker 160A
      • 4 Pole Circuit Breaker 250A
      • 4 Pole Circuit Breaker 200A
      • Circuit Breaker Padlock
      • 4 Pole Circuit Breaker 400A
      • Neutral Earth Link
      • Overload via Alarm Switch on Breaker
    • Testing & Packaging
      • PGS Test Report @ 1.0PF
      • PGS Test Report @ 0.8PF