Configuration

Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications

Modes of Operation

Multi-unit Island and multi-unit standby mode with optional redundant controls and components.

Application

LV and MV (208V - 38 kV)

SPECIFICATIONS

EGP (Emergency Generator Paralleling) switchgear is used for paralleling multiple generators that are not directly connected to a utility source.

    Environmental Parameters

    Certifications

    IBC, CBC, UBC & OSHPD Certified

    Control Panel Enclosure

    NEMA 1 or NEMA 3R Freestanding Construction

    Operating Temperature

    0°C to 50°C

    Storage Temperature

    -20°C to +60°C

    Low Voltage Standards

    NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70

    Medium Voltage Standards

    NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110

    Generator Protective Devices

    ANSI Protective Devices

    15/25, 27/59, 81 O/U, 32, 40, 50, 51

    Technical Summary

    Configuration

    Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie and load breakers in conjunction with downstream transfer switches for standby or emergency applications

    Modes of Operation

    Multi-unit Island and multi-unit standby mode with optional redundant controls and components.

    Application

    LV and MV (208V - 38 kV)

    • EGP Switchgear
      • Choice of 19” Surface Acoustic Wave Color or 15” Resistive Color Touchscreen
      • Emergency Stop Button for each generator
      • Instant Auto Switch
      • Generator Demand Priority Control
      • Audible Alarm & Horn Silence Button
      • Circuit Breaker Control Switch with Indicators

    • Data Table Interface
      • * Accomodates interface with a building management system for monitoring all system parameters via Modbus RTU or TCP
    • Supplemental Hardware Synchronization check relay (ANSI 25 Device)
      • * Provides additional discrete synchronization protection
    • Remote Power Monitoring System
      • * To monitor breaker status, alarms, metering and other operating parameters