THIS IS MY SELECT

Gas Compression Electric Motors

CN5086 Electric Motor

Voltage/Frequency

4000V ± 10%/60 Hz

Type of EX-Protection

Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC)

Insulation

Class F

SPECIFICATIONS

Get power built for your most demanding gas compression applications. Every Cat® electric motor is tested at each stage of production to make sure it performs reliably under load and according to your process requirements. High operating efficiency and low operating costs come with low noise levels and no emissions. Cat electric motors for gas compression are backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty.

    Electric Motor Specifications

    Voltage/Frequency

    4000V ± 10%/60 Hz

    Type of EX-Protection

    Class 1 Division 2, Group A,B,C,D T3 (NEC or CEC)

    Insulation

    Class F

    Shaft

    8.5 in

    Temperature Rise

    Class B at rated load

    Maximum Ambient Temperature

    104 °F

    Locked Rotor Torque

    60%

    Locked Rotor Amps

    520% Code E

    Standards

    NEMA MG1

    Rated Torque

    29,366 lb/ft

    Connection of Stator Winding

    Star

    Full Load Speed

    894 r/min

    Number of Poles

    8

    Mounting Designation

    F1 or F2

    Electric Motor Type

    Squirrel Cage Induction Motor

    Enclosure Type/Method of Cooling

    WP-II

    Duty

    Continuous

    Maximum Altitude - Before Derate

    3,000 ft

    Full Load Current

    658 Amps

    Service Factor

    1.15 SF

    Breakdown Torque

    190%

    No Load Current

    200 Amps

    • Bearings
      • Self-lubricated sleeve bearings
      • Insulated non-drive end bearings to reduce bearing currents
      • Bearing RTDs for temperature monitoring
    • Rotors
      • Designed for minimal vibration
      • Dynamic balancing at full operational speed
      • Fabricated copper squirrel cages
      • Oversized, forged, keyless shaft
      • AISI 4140/DIN42CrMo4 shaft
    • Stators
      • Radial air ducts ensure uniform and efficient cooling
      • Vacuum pressure impregnated with specially formulated epoxy resin
      • 2X RTDS per Phase
      • Space heater
      • Welded and machined stator core retains its rigidity throughout motor life to ensure a sealed and homogeneous insulation system that results in high dielectric strength, excellent heat transfer and the elimination of hazardous internal partial discharges