Rating Range

200-5000A

Transfer Type

Bypass isolation, Closed transition

Switch Type

Power Breaker

SPECIFICATIONS

Cat transfer switches are designed for a variety of standby power applications. They provide flexibility, reliability and value in a compact package. A Bypass Isolation Automatic Transfer Switch (ATS) provides fully functioning transfer in applications where emergency power to critical loads must be maintained at all times with no interruption. This type of design allows for inspection, maintenance or replacement of the power switching mechanisms with no interruption in electrical service. Breaker based Bypass isolation ATS are available from 200A to 5,000A.

    Ratings

    Control Power

    200-5000A, 2-, 3-, 4-pole<br>100% rated Short

    System Voltage Application

    120-600 Vac 50/60 Hz

    Time Withstand

    85,000 for 30 cycles

    Withstand

    100 kAIC at 600V, 3 cycles

    Applicable Testing

    CSA C22.2 No. 178 certified<br> UL 1008 listed up to 3200A<br>4000A, and 5000A UL 891 listed

    Technical Summary

    Rating Range

    200-5000A

    Transfer Type

    Bypass isolation, Closed transition

    Switch Type

    Power Breaker

    • Controls and Wiring
      • All controls relays and industrial grade relays are totally encapsulated to minimize exposure to dust and dirt. Lugs are 90º rated and all control wire is #16 AWG, type XLPE with a 125º temperature rating.
    • Enclosure
      • Durable powder-coated steel NEMA 1, 3R or 12 enclosures with three door hinges to ensure proper support of the door and door mounted devices. The hinges have removable hinge pins to facilitate door removal for easy wall mounting or service and are supplied with pad-lockable latches.

    • Available Options
      • Surge suppression
      • Field selectable, multi ratio, control voltage transformer 50/60 Hz
      • Integrated service entrance
      • Space heaters
      • Remote communications
      • Multi-meter options available
      • 2- or 4-position test switch
      • Selectable automatic or non-automatic operation
      • Open or closed transition
      • Load sequencing contacts
      • Integral overcurrent protection
      • Seismic Zone 4 Qualified (BOCA, CBC, IBC, UBC and OSHPD)
    • Optional Delayed Transition includes:
      • Pre-transfer signal with 1 N.O. and 1 N.C. contacts
      • Time delay neutral
      • In-phase transition