THIS IS MY SELECT

Configuration

Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications

Modes of Operation

Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power

Application

LV and MV ( 208V - 38 kV

SPECIFICATIONS

The Emergency Transfer and Load management (XLM) product supports transfer between the utility source and generator bus and allows for sustained parallel operation with the utility for load management applications.

    Environmental Parameters

    Certifications

    IBS, CBC, UBC & OSHPD Certified

    Control Panel Enclosure

    NEMA 1 or NEMA 3R, Freestanding Construction

    Operating Temperature

    0 degrees to 50 degrees C

    Storage Temperature

    -20 degrees C to +60 degrees C

    Low Voltage Standards

    NEMA SG-5, CSA, ANSI C37.51, ANSI C37.20.1, UL 1558 or UL 891, NFPA 110, NFPA 99 and NFPA 70

    Medium Voltage Standards

    NEMA SG-5, ANSI / IEEE C37.20.2, CSA-C22.2 No. 31-M89, EEMAC G8-3.2, NFPA 70, NFPA 99 and NFPA 1110

    Generator Protective Devices

    ANSI Protective Devices

    15/25, 27/59, 81 O/U, 32, 40, 50, 51

    Technical Summary

    Configuration

    Configurable PLC based switchgear capable of controlling and monitoring multiple generator sets, tie, utility and load breakers for utility paralleling applications

    Modes of Operation

    Emergency Standby, Utility Import/Export, Peak shaving, and base load operations with redundant controls and components. Closed transition to/from generator power

    Application

    LV and MV ( 208V - 38 kV

    Utility Protective Devices

    ANSI Protective Devices

    15/25, 27/59, 81 O/U, 32, 40, 47, 50, 51, 86

    • Generator Demand Priority Control
      • Automatically match the on-line generator capacity to the loads, and avoid unnecessary operation of generator sets.

    • Data Table Interface
      • Accommodates interface with a building management system for monitoring all system parameters via Modbus RTU or TCP
    • Supplemental Hardware Synchronization check relay (ANSI 25 Device)
      • Provides additional discrete synchronization protection
    • Remote Power Monitoring System
      • To monitor breaker status, alarms, metering and other operating parameters