The CBS Series – Open Transition, Delayed Transition (CBSD), Closed Transition (CBSCT), ATS with Bypass Isolationis is equipped with an intuitive full-color touchscreen HMI and is compatible with Ekip Connect software for commissioning and operation.
The CBS Series has an array of standard programmable functions and is built for high performance and service with proactive outage mitigation that monitors temperature and contact health. Fast switching and no line voltages connected at the door provide advanced safety.
System Information
Product nodes
Rated Voltage and Frequency
Phase system
Number of poles
Neutral configuration
Product type
Technical Summary
Rating Range
Transfer Type
Switch Type
- Control
- Color touchscreen
- Voltage and frequency settings: Pick up and Drop out
- Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
- Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
- Additional Features
- LED indications for ATS, S1 and S2 status
- Programmable digital inputs/outputs
- Auto config (voltage, frequency, phase system)
- Source priority (Source 1/2, No priority)
- Manual re-transfer
- In-phase monitor (synchro check)
- Genset exercising: on-load, off-load
- In-built power meter module
- Load shedding
- Real time clock
- Event log
- Predictive maintenance
- Voltage and current harmonics measuring
- Accessories
- Auxiliary contacts for position indication
- Digital input/output modules (factory programmed)
- 12-24 VDC aux supply module for controller
- Communication modules
- Connectivity Capability
- Modbus RTU (RS-485)
- Modbus/TCP
- Profibus DP
- ProfiNet Yes
- DeviceNet
- Ethernet IP
- Applications
- Utility - Utility
- Utility - Generator
- UL short circuit withstand ratings
- Coordinated breaker WCR
- Time-based WCR
- Short-time ratings
- Options
- Options not available