THIS IS MY SELECT

ATS TruOne - TruControl

Cat® CS – ATS (Spec Grade)

Rating Range

30 - 3000 A

Transfer Type

Open Transition (CS), Delayed Transition (CSD), Closed Transition (CSCT)

Switch Type

Contactor

SPECIFICATIONS

The CS Series – Contactor-type, Open Transition (CS), Delayed Transition (CSD), Closed Transition (CSCT) ATS is equipped with an intuitive full-color touchscreen HMI and is compatible with Ekip Connect software for commissioning and operation.

The CS Series has an array of standard programmable functions and is built for high performance and service with proactive outage mitigation that monitors temperature and contact health.

    System Information

    Product nodes

    UL: 30-200 A, 260-1200 A, 1600-3000 A

    Rated Voltage and Frequency

    200-480VAC, 50/60 Hz

    Phase system

    Single and Three

    Number of poles

    2, 3 and 4

    Neutral configuration

    Solid neutral, Switched neutral, (Optional) Overlapping neutral

    Product type

    Open transition (I-II), Delayed Transition (I-O-II), Closed transition (I-O-II) 1600-3000A only

    Technical Summary

    Rating Range

    30 - 3000 A

    Transfer Type

    Open Transition (CS), Delayed Transition (CSD), Closed Transition (CSCT)

    Switch Type

    Contactor

    • Control
      • Color touchscreen
      • Voltage and frequency settings: Pick up and Drop out
      • Time Delay Settings: Override momentary, Transfer, Generator stop, Center-OFF (Delayed Transition Type), Pre-transfer, Post-transfer, Elevator Pre-signal, Elevator Post-signal, and Load shead.
      • Source failure detections: No Voltage, Under/Over Voltage, Phase missing, Voltage unbalance, Invalid frequency, and Incorrect phase sequence
    • Additional Features
      • LED indications for ATS, S1 and S2 status
      • Programmable digital inputs/outputs
      • Auto config (voltage, frequency, phase system)
      • Source priority (Source 1/2, No priority)
      • Manual re-transfer
      • In-phase monitor (synchro check)
      • Genset exercising: on-load, off-load
      • In-built power meter module
      • Load shedding
      • Real time clock
      • Event log
      • Predictive maintenance
      • Voltage and current harmonics measuring
    • Accessories
      • Auxiliary contacts for position indication
      • Digital input/output modules (factory programmed)
      • 12-24 VDC aux supply module for controller
      • Communication modules
    • Connectivity Capability
      • Modbus RTU (RS-485)
      • Modbus/TCP
      • Profibus DP
      • ProfiNet Yes
      • DeviceNet
      • Ethernet IP
    • Applications
      • Utility - Utility
      • Utility - Generator
    • UL short circuit withstand ratings
      • Coordinated breaker WCR
      • Time-based WCR
      • Short-time ratings

    • Optional Neutral Configuration
      • Overlapping neutral