THIS IS MY SELECT

Diesel Generator Sets

3512 Generator Set

Maximum Rating

1250 ekW

Minimum Rating

890 ekW

Emissions/Fuel Strategy

Low Fuel Consumption

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    3512 TA, V-12, 4-Stroke Water-Cooled Diesel

    Bore

    6.69 in

    Stroke

    7.48 in

    Displacement

    3,161.03 in³

    Compression Ratio

    13.5:1

    Aspiration

    TA

    Fuel System

    Direct Unit Injection

    Governor Type

    Woodward

    Generator Set Dimensions

    Length - Minimum

    214.8 in

    Length - Maximum

    218.8 in

    Width - Maximum

    77.8 in

    Height - Maximum

    93.2 in

    Dry Weight - Genset (minimum)

    22,210 lb

    Dry Weight - Genset (maximum)

    22,650 lb

    Generator Set Specifications

    Maximum Rating

    1250 ekW

    Minimum Rating

    890 ekW

    Emissions/Fuel Strategy

    Low Fuel Consumption

    Voltage

    380 to 13800 Volts

    Frequency

    60 Hz

    Speed

    1800 rpm

    Duty Cycle

    Standby, Mission Critical, Prime, Continuous

    Standby Rating

    1250/1100 ekW

    Prime Power Rating

    1135/1000 ekW

    • Air Inlet System
      • Air cleaner; single element canister type with service indicator
    • Air Inlet
      • Air cleaner
    • Cooling
      • Radiator fan and fan drive
      • JWAC.
    • Exhaust
      • Exhaust flange outlet
      • Dry exhaust manifold
    • Fuel
      • Secondary fuel filters
      • Primary fuel filter with integral water separator
      • Fuel cooler; not included with packages without radiator
      • Secondary fuel filters
      • Fuel priming pump
    • Generator
      • IP23 Protection
      • Matched to the performance and output characteristics of Cat engines
    • Power Termination
      • Busbar
    • Control Panel
      • Accessory module data link
      • Features include:
      • Over/under voltage (27 / 59)
      • Coolant temperature
      • Generator phase sequence
      • Serial annunciator module data link
      • Low coolant temperature
      • Low oil pressure
      • DC volts
      • Over/under voltage (27/59)
      • Auto/start/stop control
      • Exciter diode monitor
      • Failure to start (overcrank)
      • 6 programmable digital inputs
      • Emergency stop
      • Generator mounted - rear facing
      • Programmable protective relaying functions:
      • Power factor (per phase & average)
      • Alarm acknowledge
      • DC volts
      • kVA (per phase, average & percent)
      • Overspeed
      • IVR includes:
      • RFI suppression
      • Emergency stop pushbutton
      • Package mounted radiator (except C175)
      • Overspeed
      • Emergency stop
      • kVAr (per phase, average & percent)
      • Environmental sealed front face
      • Customer data link (Modbus RTU)
      • Min / max exciter limiter
      • Speed adjust
      • Operating hours
      • True RMS AC metering, 3-phase, +/-2% accuracy
      • Reactive droop capability
      • Customizable screens
      • Volts (L-L & L-N)
      • PLC functionality
      • Digital indication for:
      • RPM
      • High coolant temperature
      • Digital indication for:
      • kW-hr (total)
      • Over/under frequency (81 o / u)
      • Low coolant temperature
      • 24 Volt DC operation
      • kW-hr (total)
      • Oil pressure (psi, kPa or bar)
      • Warning/shutdown with common LED indication of shutdowns for:
      • kVAr-hr (total)
      • EMCP 4.2B
      • 2 Programmable relay outputs (Form C)
      • kVAr-hr (total)
      • kW (per phase, average & percent)
      • kVAr (per phase, average & percent)
      • Engine cool-down timer
      • Over/under frequency (81 o/u)
      • Engine cool-down timer
      • True RMS AC metering, 3-phase, +/-2% accuracy
      • Low coolant level
      • Frequency (Hz)
      • Controls:
      • Generator phase sequence
      • High coolant temperature
      • Communications:
      • Reverse power (kW) (32)
      • Volts (L-L & L-N), frequency (Hz)
      • Alarm acknowledge
      • Environmental sealed front face
      • Controls:
      • Operating hours
      • Generator mounted - rear facing
      • Power factor (per phase & average)
      • kW (per phase, average & percent)
      • Programmable protective relaying functions:
      • Engine cycle crank
      • Reverse power (kW) (32)
      • 24 Volt DC operation
      • Lamp test
      • Text alarm/event descriptions
      • Failure to start (overcrank)
      • Generator set packages include Caterpillar's voltage regulator (IVR)
      • Warning/shutdown with common LED indication of shutdowns for:
      • Text alarm/event descriptions
      • 4 programmable relay outputs (Form A)
      • Lamp test
      • Load histogram feature
      • Coolant temperature
      • Auto/start/stop control
      • Overcurrent (50 / 51)
      • kVA (per phase, average & percent)
      • KVAR/PF modes
      • Engine cycle crank
      • 3 Phase voltage sensing
      • 2 Programmable digital outputs
      • Low oil pressure
      • Reverse reactive power (kVAr) (32RV)
      • EMCP 4 Genset controller
      • RPM
      • Oil pressure (psi, kPa or bar)
      • Amps (per phase & average)
      • Low coolant level
      • Amps (per phase & average)
      • EMCP4.2 controller includes:
    • Cooling System
      • Radiator fan and fan drive
      • Fan and belt guards
      • JWAC
      • Caterpillar extended life coolant
      • Coolant level sensors
      • Coolant drain line with valve
    • Exhaust System
      • Dry exhaust manifold.
      • Exhaust flange outlet
    • Fuel System
      • Fuel cooler; not included with packages without radiator
      • Flexible fuel lines - shipped loose
      • Secondary fuel filters
      • Fuel priming pump
    • Generators and Attachments
      • LV
      • Winding temperature detectors
      • 3 phase brushless, Salient pole
      • 1800 Frames are Form wound, Permanent magnet excitation (PMG), with winding
        temperature detectors
      • NEMA Class H insulation system, Class H temperature rise at 40C ambient (125C prime/150C standby)
      • Generator set packages include Caterpillar's digital voltage
        regulator (CDVR)
      • CDVR includes reactive droop capability, 3-phase voltage sensing, KVAR/PF modes, RFI suppression, min/max exciter. Limiter and exciter diode monitor
      • 6 Lead
      • Internal excitation (IE)
      • Busbar connections, top center mounted, top cable entry. 50 Hz models: IEC standard hole pattern
      • Random wound
    • Governing System
      • Woodward 2301A isochronous governor
    • Lube System
      • Integral lube Oil cooler
      • Oil filter, filler and dipstick
      • Oil drain lines and valve
      • Fumes disposal
      • Gear type lube oil pump.
      • Lubricating oil
    • Mounting System
      • Rubber anti-vibration mounts - shipped loose
      • Rails - engine/generator/radiator mounting
    • Starting / Charging System
      • Battery disconnect switch
      • Battery and battery rack w/cables
      • 24 Volt electric starting motor
    • Generator and Attachments
      • Random wound
      • LV
      • 6 Lead
      • 3 phase brushless, Salient pole
    • General
      • Right hand servicing
      • Caterpillar yellow with high gloss black rails & radiator
      • Flywheel and Flywheel housing-SAE No. 00
      • SAE standard rotation
      • Paint - Caterpillar yellow except rails and radiators gloss black

    • Exhaust
      • Exhaust mufflers
    • Air Inlet System
      • Air inlet protection
      • Air cleaner - Dual element
      • Remote air inlet adapters
    • Generator
      • Oversize and premium generators
      • Internal excitation (IE)
      • Permanent magnet excitation (PMG)
      • Anti-condensation heater
    • Circuit breakers
      • Breaker harnesses
      • EMAX breaker connections
      • EMAX breakers
      • Enclosures - Control packaging
      • Cable entry options
      • Low voltage, IEC standard hole
      • Optional busbar power connections
      • Busbar connections
    • Power Termination
      • Circuit breakers, IEC compliant
      • Circuit breakers, UL listed
    • Control Panels
      • Annunciator modules
      • Customer interface options
      • Auxiliary box
      • Mounting group - External box clips
      • Governors
      • Generator temperature monitoring
    • Cooling System
      • Heat exchangers
      • 3512 MUI 1500 Radiators PGS
      • Water level switch gauges
    • Mounting
      • Spring type vibration isolators
      • IBC isolators
      • Rubber anti-vibration mounts
    • Certificates
      • EU Declaration of Conformity
      • Eurasian Conformity (EAC) mark
      • European union certification
      • European Directive genset, DoI (Declaration of Incorporation)
    • Starting/Charging
      • Jacket water heater
      • Battery chargers
      • Charging alternator
      • Heavy duty starting system
      • Oversize batteries
      • Air starting motor with control and silencer
    • Exhaust System
      • Flexible fittings
      • Mufflers
      • Through wall installation kit
    • Fuel System
      • Primary fuel filter
    • Generators and Attachments
      • Space heater kit
      • Generator conversions - IE and PM
    • Instrumentation
      • Pyrometers
    • Lube System
      • Oil level reg-1 shallow pan
      • Manual prelube sump pumps
      • Electric prelube pumps
    • Mounting System
      • Vibration isolator options
    • Protection System
      • Explosion relief valves
    • Special Tests / Reports
      • PGS Test report @ 0.8 power factor
      • Neutral ground - LV
      • PGS Test report @ 1.0 power factor
      • IBC seismic Certification
      • Neutral grounding connection
    • Starting / Charging System
      • Battery chargers (10 and 20 amp)
      • Battery sets - 24 Volt, dry
      • Electric starting motors - Dual 24 Volt
      • Charging alternators
      • Jacket water heaters
      • Starting aids
    • General
      • Integral & sub-base fuel tanks
      • Enclosures: Sound attenuated, weather protective
      • Engine barring group - installed
      • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
      • CSA Certification
      • Integral & sub-base UL listed dual wall fuel tanks
      • The following options are based on regional and product configuration:
      • Automatic transfer switches (ATS)
      • UL 2200 package
      • EU Certificate of Conformance (CE)
      • EEC Declaration of Conformity

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN