THIS IS MY SELECT

Diesel Generator Sets

3512B Diesel Generator Set

Standby Rating

1875/1750 kVA

Prime Power Rating

1700/1600 kVA

Emissions/Fuel Strategy

Low Fuel , Low Emissions

SPECIFICATIONS

1600 - 1875 kVA at 50 Hz Diesel Genset
The 3512B generator set has been developed for a wide range of applications, from emergency standby installations such as healthcare and datacenters to continuously powering remote installations. The packages can be optimized for performance that matters to you with either low emissions or low fuel consumption versions available. Backed by the worldwide network of Cat dealers ready to support your operation with technical support, service, parts, and warranty, Cat generator sets will provide the reliability and durability you expect.
Q. Does this generator comply with ISO 8528 guidelines?
A. Yes, the 3512B, like all of our generators, is tested in accordnace the load steps outlined in with ISO 8528, Part 5.

    Engine Specifications

    Engine Model

    3512B TA, V-12, 4-Stroke Water-Cooled Diesel

    Bore

    6.69 in

    Stroke

    7.48 in

    Stroke - HD

    8.46 in

    Displacement

    3,161.03 in³

    Displacement - HD

    3,576 in³

    Compression Ratio

    15.5:1 HD

    Aspiration

    TA

    Fuel System

    Electronic Unit Injection

    Governor Type

    ADEM™ A3

    Generator Set Dimensions

    Length - Minimum

    212.8 in

    Length - Maximum

    217.1 in

    Width - Minimum

    90 in

    Width - Maximum

    90 in

    Height - Minimum

    94.9 in

    Height - Maximum

    94.9 in

    Dry Weight - Genset (minimum)

    25,620 lb

    Dry Weight - Genset (maximum)

    26,530 lb

    Generator Set Specifications

    Standby Rating

    1875/1750 kVA

    Prime Power Rating

    1700/1600 kVA

    Emissions/Fuel Strategy

    Low Fuel , Low Emissions

    Voltage

    400 to 415 Volts

    Frequency

    50 Hz

    Speed

    1500 rpm

    Duty Cycle

    Standby, Mission Critical, Prime, Continuous

    Minimum Rating

    1600 kVA

    Maximum Rating

    1875 kVA

    • Control System
      • EMCP 4.2B
      • Emergency stop pushbutton
      • Failure to start (overcrank)
      • High coolant temperature
      • 4 Programmable digital outputs
      • Auto/start/stop control
      • 4 Programmable digital inputs
      • DC volts
      • Engine cycle crank
      • Low coolant level
      • Speed adjust
      • Low oil pressure
      • Communications
      • Frequency (Hz)
      • Warnings/shutdown indicators
      • Engine cool-down timer
      • Operating hours
      • Emergency stop
      • Oil pressure
      • Lamp test
      • True RMS AC metering, 3-phase, +/-2% accuracy
      • Digital indication for:
      • Overspeed
      • Alarm acknowledge
      • RPM
      • 24 Volt DC operation
      • Amps (per phase & average)
      • Coolant temperature
      • Volts (L-L & L-N)
    • Governing System
      • ADEM III
    • Cooling System
      • SCAC
      • Coolant drain line with valve
      • Radiator fan and fan drive
      • Fan and belt guards
      • Coolant level sensors
      • Caterpillar extended life coolant
    • Exhaust System
      • Dry exhaust manifold
      • Flanged faced outlet(s)
    • Fuel System
      • Fuel cooler; not included with packages without radiator
      • Flexible fuel lines
      • Secondary fuel filters.
      • Fuel priming pump
    • Generator System
      • RFI suppression
      • Min / max exciter
      • 3 phase brushless, Salient pole
      • Caterpillar's digital voltage regulator (CDVR)
      • Class H temperature rise at 40C ambient
      • Random wound
      • Winding temperature detectors
      • Internal excitation (IE)
      • 3 Phase voltage sensing
      • Busbar connections
      • 6 Leads
      • NEMA Class H insulation
    • Literature
      • Parts book
      • Operation & Maintenance Manual
    • Lube System
      • Lubricating oil
      • Gear type lube oil pump
      • Fumes disposal
      • Oil drain lines and valve
      • Oil filter, filler and dipstick
      • Integral lube Oil cooler
    • Mounting System
      • Rails - Engine/generator/radiator mounting
    • General
      • Flywheel and Flywheel housing-SAE
      • Caterpillar yellow with high gloss black rails & radiator
      • RH service
      • SAE standard rotation

    • Air Inlet System
      • Dual element air cleaner
      • Single element filter
      • Heavy duty air cleaner
    • Exhaust
      • Exhaust mufflers
    • Generator
      • Internal excitation (IE)
      • Oversize and premium generators
      • Anti-condensation heater
      • Permanent magnet excitation (PMG)
    • Control System
      • EMCP voltage and current sensing groups
      • CAN2 network equipment
      • Annunciator modules (Local and remote)
      • Customer interface options
      • Load share module options (LV)
      • EMCP 4.3, EMCP 4.4
      • Annunciator network equipment
      • Neutral to ground connection
      • Generator temperature monitoring
      • Remote annunciator module (Low voltage)
      • Local annunciator modules (Low voltage)
      • Cat connect: Ethernet telematics / Satellite telematics / Cell telematics
      • Governors (MUI-Low voltage)
    • Power Termination
      • Circuit breakers, IEC compliant
      • Circuit breakers, UL listed
    • Cooling System
      • Installed radiators
      • Coolant
      • Water level switch gauges
      • Cooling system attachments
    • Mounting
      • IBC isolators
      • Rubber anti-vibration mounts
      • Spring type vibration isolators
    • Starting/Charging
      • Jacket water heater
      • Oversize batteries
      • Battery chargers
      • Charging alternator
      • Heavy duty starting system
      • Air starting motor with control and silencer
    • Exhaust System
      • Flexible fittings
      • Mufflers
      • Y Adapters
      • Elbows
      • Flange and exhaust expanders
    • Factory Support
      • Factory commissioning
    • Fuel System
      • Secondary fuel filters
      • Primary fuel filter
    • Generators and Attachments
      • Internally excitation
      • Permanent magnet excitation (PMG)
      • RW
      • 6 Leads
      • Space heater kit
      • 1400 and 1600 Frame
      • Pitch 0.6667
      • Low voltage generators 380, 400, 415 Volts 3 Phase, 1500 rpm
      • Generator conversion kits - PM to IE / IE to PM
    • General
      • EU Certificate of Conformance (CE)
      • The following options are based on regional and product configuration:
      • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
      • UL 2200 package
    • Instrumentation
      • Pyrometer and thermocouples
    • Lube System
      • Lube oil in standard sump
      • Standard sump oil pan
      • Lube oil filters
      • Drain GP oil pan
      • Oil level regulator
      • Prelube pump groups
    • Crankcase System
      • Crankcase protection group
      • Crankcase ventilation system
    • Mounting System
      • Low efficiency isolators
      • Low efficiency isolators puck
      • Low isolators
      • Spring type vibration isolators
    • Power Connections
      • Low voltage - Power connection options
      • Electrically operated circuit breakers
      • Low voltage - Package mounted circuit breakers
      • Low voltage - 1400 and 1600 Frame generators
    • Special Tests / Reports
      • Custom generator TVA report
      • PGS Test report @ 1.0 power factor
      • Generator fuel consumption test
      • Standard generator TVA report
      • PGS Test report @ 0.8 power factor
      • Generator test report
      • Standard engine test charge
    • Starting / Charging System
      • 20 Amp Battery charger
      • 10 Amp Battery charger
      • Electric starting motors
      • Starter cover
      • Batteries, racks and cables
      • Jacket water heater wiring groups
      • Jacket water heaters
      • 35 Amp Battery charger
    • Extended Service Coverage
      • Gold - 36,48, 60, 120 month coverage
      • Cat branded commercial power system
      • Silver - 36 ,48, 60, 120 month coverage
      • Platinum - 24, 36, 48, 60, 120 month coverage

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN