THIS IS MY SELECT

Diesel Generator Sets

3512B Diesel Generator Set

Maximum Rating

1500 ekW

Minimum Rating

1230 ekW

Emissions/Fuel Strategy

Low Fuel, Low Emissions

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    3512B TA, V-12, 4-Stroke Water-Cooled Diesel

    Bore

    6.69 in

    Stroke

    7.48 in

    Displacement

    3,573.55 in³

    Compression Ratio

    14.0:1 Std 15.5:1 HD

    Aspiration

    TA

    Fuel System

    Electronic Unit Injection

    Governor Type

    ADEM™ A3

    Generator Set Dimensions

    Length - Maximum

    221.9 in

    Width - Maximum

    90 in

    Height - Maximum

    93.2 in

    Dry Weight - Genset (minimum)

    24,430 lb

    Dry Weight - Genset (maximum)

    25,090 lb

    Generator Set Specifications

    Maximum Rating

    1500 ekW

    Minimum Rating

    1230 ekW

    Emissions/Fuel Strategy

    Low Fuel, Low Emissions

    Voltage

    380 to 13800 Volts

    Frequency

    60 Hz

    Speed

    1800 rpm

    Duty Cycle

    Standby, Mission Critical, Prime, Continuous

    Standby Rating

    1500/1400 ekW

    Prime Power Rating

    1360/1275 ekW

    • Air Inlet System
      • Air cleaner; single element canister type with service indicator
    • Exhaust System
      • Exhaust flange outlet
      • Dry exhaust manifold
      • Flanged faced outlet(s)
    • Generator
      • IP23 Protection
      • Matched to the performance and output characteristics of Cat engines
    • Power Termination
      • Busbar
    • Control Panel
      • Cat ECS Genset controller
    • Control System
      • Alarm acknowledge
      • kW-hr (total)
      • Lamp test
      • Over/under voltage (27 / 59)
      • Digital indication for:
      • DC volts
      • PLC functionality
      • Speed adjust
      • 4 Programmable relay outputs (Form A)?
      • Text alarm/event descriptions
      • Warning/shutdown with common LED indication of shutdowns for:
      • Engine cycle crank
      • Emergency stop
      • Auto/start/stop control
      • RPM
      • Reverse power (kW) (32)
      • True RMS AC metering, 3-phase, +/-2% accuracy
      • Accessory module data link
      • Low coolant level
      • kVAr-hr (total)
      • kVAr (per phase, average & percent)
      • 1 Programmable relay outputs (Form C)
      • Over/under frequency (81 o/u)
      • Low oil pressure
      • Amps (per phase & average)
      • Failure to start (overcrank)
      • Cat ECS 100
      • Controls:
      • High coolant temperature
      • Communications
      • Number of I/O varies on options selected
      • 24 Volt DC operation
      • Engine cool-down timer
      • Low coolant temperature
      • Generator phase sequence
      • Frequency (Hz)
      • Volts (L-L & L-N)
      • Reverse reactive power (kVAr) (32RV)
      • Oil pressure (psi, kPa or bar)
      • Customizable screens
      • Generator set packages include Caterpillar's voltage
        regulator (IVR). IVR includes reactive droop capability, 3-phase voltage sensing, KVAR / PF modes, RFI suppression, min max exciter. Limiter and exciter diode monitor
      • Load histogram feature
      • 1 Programmable digital outputs
      • Customer data link (Modbus RTU)
      • Overspeed
      • Environmental sealed front face
      • Coolant temperature
      • kW (per phase, average & percent)
      • Programmable protective relaying functions:
      • kVA (per phase, average & percent)
      • Power factor (per phase & average)
      • Emergency stop pushbutton
      • Generator mounted - rear facing
      • Cat connect
      • Overcurrent (50 / 51)
    • Cooling System
      • Package mounted radiator
      • Radiator fan and fan drive
      • Fan and belt guards
      • Coolant drain line with valve
      • Caterpillar extended life coolant (Not included with packages without radiator, installed SF44CTS
      • Coolant level sensors (Not included with packages without radiator)
      • SCAC
    • Fuel System
      • Primary fuel filter with integral water separator
      • Secondary fuel filters
      • Flexible fuel lines - shipped loose
      • Fuel priming pump
      • Fuel cooler; not included with packages without radiator
    • Generators and Attachments
      • Low voltage:
      • Random wound
      • 6 Leads
      • NEMA standard hole pattern
      • High voltage
      • Busbar connections, right side extension box, bottom cable entry
      • NEMA Class H insulation system, Class H temperature rise at 40C ambient
        (125C prime / 150C standby)
      • Permanent magnet excitation (PMG)
      • NEMA standard hole pattern
      • Medium voltage:
      • Busbar connections, top center mounted, top cable entry
      • NEMA Class H insulation system, Class H temperature rise at 40C ambient
        (125C prime / 150C standby)
      • Winding temperature detectors
      • Form wound
      • 3 Phase brushless, Salient pole
      • Class H insulation, Class F temperature rise at 40C ambient (105C prime / 130C standby)
      • Internal excitation (IE)
    • Governing System
      • ADEM III
    • Literature
      • Parts book
    • Lube System
      • Lubricating oil
      • Gear type lube oil pump
      • Oil drain lines and valve
      • Fumes disposal
      • Integral lube Oil cooler
      • Oil filter, filler and dipstick
    • Mounting System
      • Rubber anti-vibration mounts - shipped loose
    • Starting / Charging System
      • Battery disconnect switch
      • Battery and battery rack w/cables
      • 45 Amp Charging alternator
      • 24 Volt electric starting motor
    • General
      • Paint - Caterpillar yellow with high gloss black rails & radiator
      • Flywheel and Flywheel housing-SAE No. 00
      • Right hand servicing
      • SAE standard rotation

    • Control Panels
      • Remote monitoring software
      • Digital I/O module
      • EMCP 4.4
      • Load share module
      • Generator temperature monitoring & protection
    • Exhaust System
      • Exhaust mufflers
      • Flanges
      • Elbows
      • Flange and exhaust expanders
      • Mufflers
      • Y Adapters
      • Flexible fittings
    • Generator
      • Oversize and premium generators
      • Permanent magnet excitation (PMG)
      • Internal excitation (IE)
      • Anti-condensation heater
    • Air Inlet System
      • Heavy duty air cleaner
      • Single element filter
    • Power Termination
      • Circuit breakers, UL listed
      • Circuit breakers, IEC compliant
    • Cooling System
      • Standard installed radiators
      • Optional installed radicators
      • Coolant
      • Water level switch gauges
    • Fuel System
      • Primary fuel filter
    • General
      • UL 2200 package
      • EEC Declaration of Conformity
      • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
      • CSA Certification
      • Enclosures: Sound attenuated, weather protective
      • Automatic transfer switches (ATS)
      • Integral & sub-base fuel tanks
      • The following options are based on regional and product configuration:
      • US aid emblem
      • Integral & sub-base UL listed dual wall fuel tanks
      • EU Certificate of Conformance (CE)
    • Generators and Attachments
      • 1400, 1600, 2700 Frames
      • Generator conversion from IE to PM
      • Space heater
      • RW, IE, 6 Leads, Pitch 0.6667
      • Low voltage: 380,440 / 480 Volts, 3 Phase, 1800 rpm
      • Differential current transformers (DCT) 15 kV class
      • Generator air cleaner
      • Differential current transformers (DCT) 8.7 kV class
    • Mounting
      • IBC isolators
      • Rubber anti-vibration mounts
      • Spring type vibration isolators
    • Starting/Charging
      • Air starting motor with control and silencer
      • Heavy duty starting system
      • Charging alternator
      • Oversize batteries
      • Battery chargers
      • Jacket water heater
    • Instrumentation
      • Wiring GP W/O cyl sensors
      • Pyrometer and thermocouples
    • Lube System
      • Lubrication oil in standard sump
      • Oil drains
      • Prelube pumps
      • Oil level regulator
    • Crankcase Protection
      • Explosion relief valves
      • No crankcase explosion relief valves
      • Crankcase ventilation system
      • No explosion relief valves
    • Mounting System
      • IBC vibration isolators
      • Puck style low efficiency isolators
      • Spring type vibration isolators
    • Power Connections
      • 2000, 2500 Amp, 4 Pole, IECrated Circuit breakers
      • Cable entry - right side
      • Grounding groups
      • Left side power connections
      • 1600 ,2000, 2500, 3000, 4000 Amp, 3 Pole, UL-100% rated Circuit breakers
      • 2000, 2500, 3200 Amp, 3 Pole, IEC rated Circuit breakers
      • Rear power connections
      • Neutral ground connections
      • 6 Leads, 6 terminal option
      • Right side power connections
      • Center post buss bar
    • Special Tests / Reports
      • Generator test report
      • PGS Test report @ 0.8 power factor
      • Standard engine test charge
      • CSA Certification
      • Torsional vibration analysis
      • Generator fuel consumption test
      • PGS Test report @ 1.0 power factor
      • IBC seismic Certification
      • Fuel consumption test
    • Starting / Charging System
      • Air pressure regulator
      • Batteries, racks and cables:
      • Air starting motor
      • 35 Amp Battery charger
      • 24 Volt battery set - Dry
      • Starter cover
      • 10 Amp Battery charger
      • Engine barring device
      • Jacket water heaters
      • Electric starting motors

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN