THIS IS MY SELECT

Diesel Generator Sets

C15 (50 Hz) China Non Road

Maximum Rating

550 kVA

Minimum Rating

365 kVA

Emissions/Fuel Strategy

Low Fuel, Tier 2 or 3

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel

    Bore

    5.4 in

    Stroke

    6.75 in

    Displacement

    927.56 in³

    Compression Ratio

    16.1:1

    Aspiration

    Air to Air Aftercooled

    Fuel System

    MEUI

    Governor Type

    Adem™A4

    Generator Set Dimensions

    Length - Maximum

    222.7 in

    Width - Maximum

    90 in

    Height - Maximum

    93.2 in

    Generator Set Specifications

    Maximum Rating

    550 kVA

    Minimum Rating

    365 kVA

    Emissions/Fuel Strategy

    Low Fuel, Tier 2 or 3

    Voltage

    208 to 600 Volts

    Frequency

    50 Hz

    Speed

    1500 rpm

    Duty Cycle

    Standby, Prime

    • Air System
      • Aftercooler core
      • Turbocharger
      • Air cleaner - Non canister disposable paper filter
    • Air Inlet
      • Air cleaner
    • Control Panel
      • GCCP 1.3
      • GCCP 1.3
    • Cooling
      • Package mounted radiator
    • Cooling System
      • Radiator and cooling fan with guard
      • Coolant drain line with valve
      • Caterpillar extended life coolant
      • Fan drive, battery charging alternator drive
    • Fuel
      • Secondary fuel filters
      • Fuel priming pump
      • Primary fuel filter with integral water separator
    • Exhaust
      • Stainless steel exhaust flex, gaskets, raincap & SAE exhaust flange
        for customer use - shipped loose
      • Exhaust flange outlet
    • Fuel System
      • Standard open set fuel tank/base supplied
      • Base, formed steel with single wall integral 8-hour fuel tank
    • Generator
      • IP23 Protection
      • Matched to the performance and output characteristics of Cat engines
      • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • Generator and Attachments
      • IP23 Protection
      • A Frame generator - IP21 Protection
      • Segregated low voltage (AC/DC) wiring panel
      • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
      • Optional LC Frame generator - IP23 Protection
      • Power center, IP22
      • Integrated voltage regulator (IVR)
    • Power Termination
      • Busbar
    • Governing System
      • Cat electronic governor (ADEM A4)
    • Lube System
      • Lubricating oil
      • Oil drain valves
    • Mounting
      • Rubber vibration isolators
    • Mounting System
      • Rubber vibration isolators
    • Starting/Charging
      • 24 Volt battery with rack and cables
      • Batteries
      • 24 volt starting motor
    • General
      • Engine and alternator pre paint, Caterpillar yellow
      • Paint - Caterpillar yellow except rails and radiators gloss black

    • Air Inlet System
      • Single element air cleaner
      • Dual element air cleaner
    • Exhaust
      • Industrial, residential, critical mufflers
    • Certifications
      • EU Certificate of Conformance (CE)
      • Global certification for CIS
    • Generator
      • Oversize and premium generators
      • Anti-condensation heater
      • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Power Termination
      • Circuit breakers, UL listed
      • Circuit breakers, IEC compliant
    • Circuit breakers
      • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
      • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
      • Auxiliary contacts, circuit breaker
      • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
      • Padlockable circuit breaker device
      • Power terminal strip
      • Shunt trip for IEC circuit breaker
      • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
    • Control Panels
      • Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
      • Remote annunciator module
      • Oil temperature displays
      • GCCP 1.4
      • Local annunciator
      • Local alarm horn
      • Volt free contacts
    • Starting/Charging
      • Jacket water heater
      • Heavy duty starting system
      • Battery chargers
      • Oversize batteries
      • Charging alternator
    • Cooling System
      • Radiator duct flange
      • Stone guards
      • Low coolant temperature alarm
    • Enclosures
      • Sound attenuated enclosures
      • High ambient sound attenuated enclosures
    • Exhaust System
      • End in/end out mufflers - 10, 25 and 35 dBA attenuation
      • Manifold and turbocharger guards
      • Flexible exhaust fittings
      • 6 and 8 inch flange GP
      • 6 and 8 inch elbow kit
      • Engine mounted muffler
    • Fuel System
      • Dual wall fuel tank base
      • Manual fuel transfer pump
      • Fuel transfer system controls
    • General
      • UL 2200 package
      • Automatic transfer switches (ATS)
      • Narrow, wide or skid base
      • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
      • Single or dual wall sub-base fuel tanks
      • EU Certificate of Conformance (CE)
      • EEC Declaration of Conformity
      • The following options are based on regional and product configuration:
      • Single or dual wall integral fuel tanks
      • CSA Certification
      • Sound attenuated, weather protective or high ambient weather protective enclosure
      • Integral & sub-base UL listed dual wall fuel tanks
    • Generator and Attachments
      • Oversize A Frame generator
      • LC frame generator
      • Oversize LC frame generator
      • CIP A Frame generator
      • LC frame CIP generator
      • Permanent magnet excitation (PMG) generator
      • Space heaters
      • Ingress protection
    • Lube System
      • Manual sump pump
    • Mounting System
      • Narrow skid base - replaces standard fuel tank base
    • Special Test / Reports
      • PGS Test report @ 1.0 power factor
      • PGS Test report @ 0.8 power factor
    • Starting / Charging System
      • 5 Amp single Battery charger
      • Battery disconnect switch

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN