THIS IS MY SELECT

Diesel Generator Sets

C15 Generator Set

Maximum Rating

500 ekW

Minimum Rating

320 ekW

Emissions/Fuel Strategy

Low Fuel, Tier 2, Tier 3, EU Stage IIIA

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C15 ATAAC, I-6, 4-Stroke Water-Cooled Diesel

    Bore

    5.4 in

    Stroke

    6.75 in

    Displacement

    927.56 in³

    Compression Ratio

    16.1:1

    Aspiration

    Air to Air Aftercooled

    Fuel System

    MEUI

    Governor Type

    Adem™A4

    Generator Set Dimensions

    Length - Maximum

    168.2 in

    Width - Maximum

    81 in

    Height - Maximum

    126.3 in

    Generator Set Specifications

    Maximum Rating

    500 ekW

    Minimum Rating

    320 ekW

    Emissions/Fuel Strategy

    Low Fuel, Tier 2, Tier 3, EU Stage IIIA

    Voltage

    208 to 600 Volts

    Frequency

    60 Hz

    Speed

    1800 RPM

    Duty Cycle

    Standby, Prime

    • Air Inlet
      • Air cleaner
    • Air System
      • Turbocharger
      • Air cleaner - Non canister disposable paper filter
      • Aftercooler core
    • Control Panel
      • GCCP 1.3
      • GCCP 1.3 Genset Controller
    • Cooling
      • Package mounted radiator
    • Cooling System
      • Caterpillar extended life coolant
      • Fan drive, battery charging alternator drive
      • Radiator and cooling fan with guard
      • Coolant drain line with valve
    • Exhaust
      • Base, formed steel with single wall integral 8-hour fuel tank
      • Standard open set fuel tank/base supplied
      • Exhaust flange outlet
    • Fuel
      • Secondary fuel filters
      • Primary fuel filter with integral water separator
      • Fuel priming pump
    • Fuel System
      • Primary fuel filter w/integral water separator and secondary filter
      • Fuel priming pump
      • Engine fuel transfer pump
      • Flexible fuel lines
      • Fuel cooler
    • Generator
      • Matched to the performance and output characteristics of Cat engines
      • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
      • IP23 Protection
    • Power Termination
      • Busbar
    • Generator and Attachments
      • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
      • Integrated voltage regulator (IVR)
      • Segregated low voltage (AC/DC) wiring panel
      • Optional LC Frame generator - IP23 Protection
      • Power center, IP22
      • A Frame generator - IP21 Protection
    • Mounting
      • Rubber vibration isolators
    • Governing System
      • Cat electronic governor (ADEM A4).
    • Lube System
      • Oil cooler
      • Oil drain valves
    • Mounting System
      • Captive linear vibration isolators between base and engine-generator includes lifting provisions and termination points for coolant and lube oil drain lines
    • Starting/Charging
      • 24 Volt battery with rack and cables
      • 24 volt starting motor
      • Batteries
    • General
      • Engine and alternator pre paint, Caterpillar yellow
      • Paint - Caterpillar yellow except rails and radiators gloss black

    • Air Inlet System
      • Single element air cleaner
      • Dual element air cleaner
    • Exhaust
      • Industrial, residential, critical mufflers
    • Certifications
      • EU Certificate of Conformance (CE)
      • Global certification for CIS
    • Circuit breakers
      • Shunt trip for IEC circuit breaker
      • Padlockable circuit breaker device
      • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
      • Auxiliary contacts, circuit breaker
      • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
      • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
      • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
      • Power terminal strip
    • Generator
      • Oversize and premium generators
      • Anti-condensation heater
      • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
    • Power Termination
      • Circuit breakers, UL listed
      • Circuit breakers, IEC compliant
    • Control Panels
      • GCCP 1.4
      • Volt free contacts
      • Local annunciator
      • Remote annunciator module
      • Local alarm horn
      • Oil temperature displays
      • Protective devices: Earth fault relay ; Earth leakage Ground fault relay ; Overload shutdown via breaker ; Low fuel level alarm ; Low fuel level shutdown ; High fuel level alarm ; Fuel level sensor
    • Starting/Charging
      • Jacket water heater
      • Charging alternator
      • Heavy duty starting system
      • Battery chargers
      • Oversize batteries
    • Cooling System
      • Stone guards
      • Radiator duct flange
      • Low coolant temperature alarm
    • Enclosures
      • Sound attenuated enclosures
      • High ambient sound attenuated enclosures
    • General
      • Sound attenuated, weather protective or high ambient weather protective enclosure
      • CSA Certification
      • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
      • EEC Declaration of Conformity
      • Integral & sub-base UL listed dual wall fuel tanks
      • Automatic transfer switches (ATS)
      • Single or dual wall sub-base fuel tanks
      • The following options are based on regional and product configuration:
      • EU Certificate of Conformance (CE)
      • Single or dual wall integral fuel tanks
      • Narrow, wide or skid base
      • UL 2200 package
    • Exhaust System
      • Engine mounted muffler
      • End in/end out mufflers - 10, 25 and 35 dBA attenuation
      • 6 and 8 inch elbow kit
      • Manifold and turbocharger guards
      • Flexible exhaust fittings
      • 6 and 8 inch flange GP
    • Fuel System
      • Manual fuel transfer pump
      • Dual wall fuel tank base
      • Fuel transfer system controls
    • Generator and Attachments
      • Space heaters
      • Permanent magnet excitation (PMG) generator
      • Ingress protection
      • LC frame generator
      • Oversize A Frame generator
      • LC frame CIP generator
      • CIP A Frame generator
      • Oversize LC frame generator
    • Lube System
      • Manual sump pump
    • Mounting System
      • Narrow skid base - replaces standard fuel tank base
    • Special Test / Reports
      • PGS Test report @ 1.0 power factor
      • PGS Test report @ 0.8 power factor
    • Starting / Charging System
      • 5 Amp single Battery charger
      • Battery disconnect switch
      • Jacket water heater