THIS IS MY SELECT

Diesel Generator Sets

C175-16 Generator Set

Maximum Rating

3100 kVA

Minimum Rating

2500 kVA

Emissions/Fuel Strategy

Low Fuel, Low Emissions

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel

    Bore

    6.89 in

    Stroke

    8.66 in

    Displacement

    5,166.88 in³

    Compression Ratio

    16.7:1

    Aspiration

    Turbo Aftercooled

    Fuel System

    Common Rail

    Governor Type

    ADEM� A4

    Generator Set Dimensions

    Length - Minimum

    241.6 in

    Length - Maximum

    311 in

    Width - Minimum

    83 in

    Width - Maximum

    108.5 in

    Height - Minimum

    87 in

    Height - Maximum

    130.2 in

    Dry Weight - Genset (minimum)

    42,750 lb

    Dry Weight - Genset (maximum)

    50,750 lb

    Generator Set Specifications

    Maximum Rating

    3100 kVA

    Minimum Rating

    2500 kVA

    Emissions/Fuel Strategy

    Low Fuel, Low Emissions

    Voltage

    380 to 11000 Volts

    Frequency

    50 Hz

    Speed

    1500 rpm

    Duty Cycle

    Standby, Mission Critical, Prime, Continuous

    Standby Rating

    3100(no fan)/3000 kVA

    Prime Power Rating

    2825(no fan)/2725 kVA

    • Air Inlet System
      • 4 x Single element canister with service indicator(s)
    • Control Panel
      • EMCP 4.2B
      • Volts (L-L & L-N)
      • Engine cycle crank
      • Power factor (per phase & average)
      • Overcurrent
      • Communications
      • Emergency stop
      • 2 Programmable relay outputs (Form C)
      • 6 Programmable digital inputs
      • 2 Programmable digital outputs
      • Environmental sealed front face.
      • DC Volts
      • Reverse power
      • Programmable protective relaying functions
      • High coolant temperature
      • Accessory module data link
      • Low coolant level
      • Over/under frequency
      • Amps (per phase & average)
      • True RMS AC metering, 3-phase, +/-2% accuracy
      • Low coolant temperature
      • Reverse reactive power
      • Controls
      • Oil pressure (psi, kPa or bar)
      • Lamp test
      • Coolant temperature
      • Warning/shutdown Indicators:
      • 4 Programmable relay outputs (Form A)
      • Alarm acknowledge
      • Generator phase sequence
      • 24 Volt DC operation
      • Serial annunciator module data link
      • Customer data link (Modbus RTU)
      • Failure to start (overcrank)
      • Auto/start/stop control.
      • Low oil pressure
      • RPM
      • Text alarm/event descriptions.
      • Digital Indicators
      • Generator mounted - rear facing
      • Emergency stop pushbutton
      • Engine cool-down timer
      • Operating hours
      • Over/under voltage
      • Overspeed
      • Frequency (Hz)
    • Cooling System
      • Radiator group - shipped loose
      • SCAC cooling
      • Coolant Sensors
      • Coolant drain line and valves
      • Fan and belt guards
    • Exhaust System
      • Bolted flange, with bellow for each turbo
      • Dry exhaust manifold
    • Fuel System
      • Filters x 3
      • Secondary/ tertiary fuel filters
      • 10 Micron spin On Type
      • 4 Micron Spin On Type
      • Primary fuel filter water/fuel water separator
      • Engine mounted filters x 3
    • Generator and Attachments
      • 6 Leads
      • IEC platinum stator RTDs
      • Voltage regulator
      • Reactive droop capability
      • 3 Phase voltage sensing
      • RFI suppression
      • Min / max exciter limiter
      • exciter diode monitor
      • Form wound
      • Permanent magnet excitation (PMG)
      • NEMA Class H insulation
      • Class H temperature rise at 40C ambient
      • (LV) Busbar connections, top/center mounted, top cable entry
      • 3 Phase Brushless
      • Salient pole
      • 50 Hz models: IEC standard hole pattern
      • (MV) Busbar connections, right side extension box, bottom cable entry
      • Anti-condensation space heater
      • Class F temperature rise at 40C ambient
      • Right side extension box, bottom cable entry
    • Governing System
      • ADEM A4
      • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
    • Lube System
      • Gear type lube oil pump
      • Lubricating oil
      • Fumes disposal
      • Integral lube Oil cooler
      • Oil drain lines and valve
      • Oil filter, filler and dipstick
      • Prelube - required with prime, continuous, and standby
    • Mounting Systems
      • Rubber anti-vibration mounts - shipped loose
      • Battery disconnect switch
      • Batteries and battery rack w/cables
      • Dual 24 volt electric starting motors
      • Rails - Engine/generator
    • Service Instructions
      • Two PM inspections
    • Power Termination
      • Busbar
    • General
      • Paint - Caterpillar yellow with high gloss black rails & radiator
      • Right hand servicing
      • Flywheel and flywheel housing-SAE No. 00
      • SAE standard rotation

    • Air Inlet System
      • Single element air cleaner
      • Dual element air cleaner
      • Air inlet adapters
      • Air inlet protection
    • Control Panel
      • EMCP 4.3, EMCP 4.4
      • EMCP 4.4 optional harness
      • EMCP and MV&HV power connection locations
      • Load share module
      • EMCP mounting location - LV / MV
      • Customer AC-DC connection mounting location - LV/MV
      • Load share module / auxiliary plate and auxiliary box (LV)
      • Load share governor
      • Frame boxes
      • Automatically selected ground
      • EMCP voltage and current sensing groups
      • Raise lower switch
      • Speed adjust
      • Annunciator modules
      • Customer interface options
      • Generator temperature monitoring
      • Modbus monitoring of packages
      • E-Stop
      • Interconnect harness
      • Generator harness
    • Cooling System
      • Package mounted radiator
      • Remote radiators
      • Fuel cooler
    • Exhaust System
      • Front housing - Standby or mission critical
      • Front housing - Prime or continuous
      • Exhaust collectors/manifold
      • Exhaust support group
      • Mufflers
      • Weld flanges
      • Aftercooler drain
    • Crankcase Systems
      • Explosive relief valves
      • Crankcase ventilation system
    • Fuel System
      • Primary fuel filter
    • Generators and Attachments
      • Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Space heater kit
      • Thermostat for space heater
      • Conversion GP - Top cable entry
      • Generator air intake
      • Differential current transformers
    • Instrumentation
      • Pyrometer and thermocouples
    • Lube System
      • Lube oil heater
      • Drain group oil pans
      • Lubricating oil
      • Electric prelube pumps
      • Oil filters
    • Mounting
      • Rubber anti-vibration mounts
      • Spring type linear vibration isolators
      • IBC vibration isolators - Shipped loose
    • Power Connections
      • Center post busbarss (LV)
      • Side/rear mounted busbars (LV)
      • Harnesses (Breaker)
      • Cable entry options (LV)
      • Enclosures - Control packaging (LV)
      • Power connection covers (LV)
      • Neutral ground (LV)
      • 1800 Frame generators Circuit breaker
      • Masterpack breakers
      • Paralleling circuit breakers
      • 1800 Frame generator side / rear mounted busbars (MV)
      • Cable entry options (MV)
      • Neutral ground (MV)
      • Low voltage connection cable
      • Masterpack breaker connections
    • Special Tests / Reports
      • Generator test report
      • PGS Test report @ 1.0 power factor
      • PGS Test report @ 0.8 power factor
      • Standard genset TVA (Torsional Vibration Analysis) report
      • Custom generator TVA report
      • Special test charge - Engine only
      • Genset fuel consumption test
      • Standard engine test charge
      • IBC seismic Certification
      • OSCOSH1 seismic Certification
    • Starting / Charging System
      • 24 Volt power distribution box
      • 24 Volt electric starting motor
      • Air starting motor
      • Air pressure regulator
      • Starter location covers
      • 24 Volt battery set - Dry
      • Heavy duty battery sets with rack
      • 20 Amp Battery chargers
      • 35 Amp Battery chargers
      • 50 Amp Battery chargers
      • Charging alternators - Dry
      • Jacket water heaters
      • Jacket water heater wiring groups
    • General
      • Special paint colors
      • Service tools - Engine barring group
      • Barring group manual
      • Engine barring air powered
      • Control GP - air powered bar group

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN