Diesel Generator Sets

C175-16 Generator Set

Maximum Rating

3365 ekW

Minimum Rating

2500 ekW

Emissions/Fuel Strategy

Low Fuel, Tier 2

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C175-16 SCAC, V-16, 4-Stroke Water-Cooled Diesel

    Bore

    6.89 in

    Stroke

    8.66 in

    Displacement

    6,456.31 in³

    Compression Ratio

    16.7:1

    Aspiration

    Turbo Aftercooled

    Fuel System

    Common Rail

    Governor Type

    ADEM� A4

    Generator Set Dimensions

    Length - Minimum

    250.9 in

    Length - Maximum

    330.6 in

    Width - Minimum

    82.7 in

    Width - Maximum

    124.3 in

    Height - Minimum

    86.9 in

    Height - Maximum

    134.2 in

    Dry Weight - Genset (minimum)

    42,750 lb

    Dry Weight - Genset (maximum)

    57,774 lb

    Generator Set Specifications

    Maximum Rating

    3365 ekW

    Minimum Rating

    2500 ekW

    Emissions/Fuel Strategy

    Low Fuel, Tier 2

    Voltage

    480 to 13800 Volts

    Frequency

    60 Hz

    Speed

    1800 RPM

    Duty Cycle

    Standby, Mission Critical, Prime, Continuous

    Standby Rating

    3365(no fan)/3250/3100(no fan)/3000 ekW

    Prime Power Rating

    3115(no fan)/3000/2825(no fan)/2725 ekW

    • Air Inlet System
      • 4 x Single element canister with service indicator(s).
    • Control Panel
      • 2 Programmable relay outputs (Form C)
      • Low coolant level
      • Over/under voltage
      • Coolant temperature
      • Serial annunciator module data link
      • Alarm acknowledge
      • Text alarm/event descriptions
      • Volts (L-L & L-N)
      • Reverse power
      • Over/under frequency
      • Environmental sealed front face
      • Programmable protective relaying functions
      • Speed adjust
      • Generator phase sequence
      • Low coolant temperature
      • Generator mounted - rear facing
      • Overspeed
      • Controls
      • Frequency (Hz)
      • Engine cycle crank
      • Engine cool-down timer
      • Warning/shutdown Indicators:
      • Lamp test
      • 2 Programmable digital outputs
      • 6 Programmable digital inputs
      • High coolant temperature
      • Customer data link (Modbus RTU)
      • Auto/start/stop control
      • Emergency stop pushbutton
      • RPM
      • Digital Indicators
      • Communications
      • Accessory module data link
      • Oil pressure (psi, kPa or bar)
      • Low oil pressure
      • Overcurrent
      • Emergency stop
      • 24 Volt DC operation
      • 4 Programmable relay outputs (Form A)
      • Failure to start (overcrank)
      • True RMS AC metering, 3-phase, +/-2% accuracy
      • Power factor (per phase & average)
      • Operating hours
      • DC volts
      • Amps (per phase & average)
      • Cat ECS 100
      • Reverse reactive power
    • Exhaust System
      • Bolted flange, with bellow for each turbo
      • Exhaust flange outlet
    • Fuel System
      • Engine mounted filters #REF!
      • Filters x 3
      • 10 Micron spin on yype
      • Secondary/tertiary fuel filters
      • 4 Micron spin on type
      • Primary fuel filter water/fuel water separator
    • Generators and Attachments
      • Right side extension box, bottom cable entry
      • IEC platinum stator RTDs
      • Reactive droop capability
      • 3 Phase voltage sensing
      • (MV) Busbar connections, right side extension box, bottom cable entry
      • Class F temperature rise at 40C ambient
      • Anti-condensation space heater
      • NEMA Class H insulation
      • 6 Leads
      • Class H temperature rise at 40C ambient
      • Voltage regulator
      • Exciter diode monitor
      • Form wound
      • RFI suppression
      • (LV) Busbar connections, top/center mounted, top cable entry
      • 3 Phase brushless
      • 60 Hz models: NEMA standard hole pattern
      • Permanent magnet excitation (PMG)
      • Min / max exciter limiter
      • Salient pole
    • Governing System
      • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
      • ADEM A4
    • Lube System
      • Oil filter, filler and dipstick
      • Integral lube Oil cooler
      • Oil drain lines and valve
      • Fumes disposal
      • Lubricating oil
      • Prelube - required with prime, continuous, and standby
      • Gear type lube oil pump
    • Mounting Systems
      • Rails - Engine/generator
      • Rubber anti-vibration mounts - shipped loose
      • Dual 24 volt electric starting motors
      • Battery disconnect switch
      • Batteries and battery rack w/cables
    • Power Termination
      • Busbar
    • Service Instructions
      • Two PM inspections
    • General
      • Paint - Caterpillar yellow with high gloss black rails & radiator
      • SAE standard rotation
      • LH Service
      • Flywheel and flywheel housing-SAE No. 00

    • Air Inlet System
      • Air inlet adapters
      • Dual element air cleaner
      • Single element air cleaner
      • Air inlet protection
    • Control Panel
      • Package mounted radiator
      • Automatically selected ground
      • Customer AC-DC connection mounting location - LV/MV
      • Load share governor
      • EMCP 4.4
      • E-Stop
      • Frame boxes
      • Annunciator modules
      • Load share module / auxiliary plate and auxiliary box (LV)
      • Fuel cooler
      • Controller mounting location - LV/MV
      • Modbus monitoring of packages
      • Customer interface options
      • EMCP 4.4 optional harness
      • Controller voltage and current sensing groups
      • Remote radiators
      • Generator harness
      • Interconnect harness
      • Speed adjust
      • Controller and MV and HV power connection locations
      • Raise lower switch
    • Crankcase Systems
      • Explosive relief valves
      • Crankcase ventilation system
    • Exhaust System
      • Mufflers
      • Exhaust support group
      • Weld flanges
      • Exhaust collectors/manifold
      • Front housing - Prime or continuous
      • Front housing - Standby or mission critical
      • Aftercooler drain
    • Fuel System
      • Primary fuel filter
    • Generators and Attachments
      • Low voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Medium voltage - 1800 and 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Conversion GP - Top cable entry
      • Low voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Differential current transformers
      • Space heater kit
      • Medium voltage - 1800 and 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Thermostat for space heater
      • Generator air intake
    • Instrumentation
      • Pyrometer and thermocouples
    • Lube System
      • Drain group oil pans
      • Oil filters
      • Lube oil heater
      • Electric prelube pumps
      • Lubricating oil
    • Mounting Systems
      • IBC vibration isolators - Shipped loose
      • Spring type linear vibration isolators
      • Rubber anti-vibration mounts
    • Power Connections
      • Low voltage connection cable
      • Center post busbarss (LV)
      • 1800 Frame generator side / rear mounted busbars (MV)
      • Enclosures - Control packaging (LV)
      • Paralleling circuit breakers
      • 1800 Frame generators Circuit breaker
      • Neutral ground (LV)
      • Neutral ground (MV)
      • Cable entry options (LV)
      • Cable entry options (MV)
      • Masterpack breakers
      • Power connection covers (LV)
      • Harnesses (Breaker)
      • Masterpack breaker connections
      • Side/rear mounted busbars (LV)
    • Special Tests / Reports
      • IBC seismic Certification
      • Special test charge - Engine only
      • PGS Test report @ 0.8 power factor
      • Genset fuel consumption test
      • Standard genset TVA (Torsional Vibration Analysis) report
      • PGS Test report @ 1.0 power factor
      • OSCOSH1 seismic Certification
      • Custom generator TVA report
      • Generator test report
      • Standard engine test charge
    • Starting / Charging System
      • Heavy duty battery sets with rack
      • Charging alternators - Dry
      • Air pressure regulator
      • Starter location covers
      • 24 Volt power distribution box
      • 24 Volt electric starting motor
      • 35 Amp Battery chargers
      • 24 Volt battery set - Dry
      • 20 Amp Battery chargers
      • Jacket water heaters
      • 50 Amp Battery chargers
      • Air starting motor
      • Jacket water heater wiring groups
    • General
      • Special paint colors
      • Control GP - air powered bar group
      • Barring group manual
      • Service tools - Engine barring group
      • Engine barring air powered