Maximum Rating

4000 kVA

Minimum Rating

3150 kVA

Emissions/Fuel Strategy

Low Fuel, Low Emissions

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel

    Bore

    6.89 in

    Stroke

    8.66 in

    Displacement

    6,456.31 in³

    Compression Ratio

    15.3:1

    Aspiration

    Turbo Aftercooled

    Fuel System

    Common Rail

    Governor Type

    ADEM� A4

    Generator Set Dimensions

    Length - Minimum

    264.2 in

    Length - Maximum

    330.8 in

    Width - Minimum

    85.1 in

    Width - Maximum

    127.8 in

    Height - Minimum

    87.6 in

    Height - Maximum

    150.7 in

    Dry Weight - Genset (minimum)

    55,100 lb

    Dry Weight - Genset (maximum)

    66,200 lb

    Generator Set Specifications

    Maximum Rating

    4000 kVA

    Minimum Rating

    3150 kVA

    Emissions/Fuel Strategy

    Low Fuel, Low Emissions

    Voltage

    400 to 11000 Volts

    Frequency

    50 Hz

    Speed

    1500 RPM

    Duty Cycle

    Standby, Mission Critical, Prime, Continuous

    Standby Rating

    4000(no fan)/3900 kVA

    Prime Power Rating

    3600(no fan)/3500 kVA

    • Air Inlet
      • 4 x Single element canister air cleaners with service indicator(s).
    • Control Panel
      • Engine cycle crank
      • Oil pressure (psi, kPa or bar)
      • Digital Indicators
      • Coolant temperature
      • Environmental sealed front face
      • Frequency (Hz)
      • True RMS AC metering, 3-phase, +/-2% accuracy
      • Text alarm/event descriptions
      • Low coolant level
      • Volts (L-L & L-N)
      • Auto/start/stop control
      • Warning/shutdown Indicators:
      • Emergency stop pushbutton
      • Engine cool-down timer
      • DC volts
      • High coolant temperature
      • Operating hours
      • Low oil pressure
      • Cat ECS 100
      • Amps (per phase & average)
      • 4 Programmable relay Inputs
      • Alarm acknowledge
      • 4 Programmable relay output
      • Failure to start (overcrank)
      • Overspeed
      • Lamp test
      • 24 Volt DC operation
      • Wall mounted controls
      • RPM
    • Cooling System
      • SCAC cooling
      • Coolant sensors
      • JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
      • AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI
    • Exhaust
      • Dry exhaust manifold
      • Bolted flange (ANSI 6" & DIN 150) with bellow for each turbo (Qty 4). 50 Hz
    • Fuel
      • Filters x 3
      • Secondary/tertiary fuel filters
      • 4 Micron spin on type
      • 10 Micron spin on type
      • Engine mounted filters x 3
      • Primary fuel filter water/fuel water separator
    • Generators and Attachments
      • Salient pole
      • RFI suppression
      • Anti-condensation space heater
      • IEC platinum Stator RTDs
      • Form wound
      • NEMA Class H insulation
      • Voltage regulator
      • Reactive droop capability
      • Min/max Exciter limiter
      • 3 Phase voltage sensing
      • Exciter diode monitor
      • 6 Leads
      • 3 Phase brushless
      • Right side extension box, bottom cable entry
      • Permanent magnet excitation (PMG)
      • Class H temperature rise at 40C ambient
    • Governing System
      • ADEM A4
      • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
    • Lube System
      • Oil drain lines and valve
      • Gear type lube oil pump
      • Oil filter, filler and dipstick
      • Integral lube Oil cooler
      • Lubricating oil
      • Fumes disposal
    • Mounting Systems
      • Rails - Engine/Generator
      • Rubber anti-vibration mounts - shipped loose
    • Starting / Charging System
      • Batteries and battery rack w/cables
      • Dual 24 volt electric starting motors
      • Battery disconnect switch
    • General
      • SAE standard rotation
      • Right hand servicing
      • Paint - Caterpillar yellow with high gloss black rails

    • Air Inlet Systems
      • Single element air cleaner
    • Control Panels
      • EMCP 4.4
      • Controller and MV and HV power connection locations
      • Load share module
      • Controller voltage and current sensing groups
      • Speed adjust
      • Annunciator modules
      • Customer interface options
      • Generator temperature monitoring
      • E-Stop
      • Interconnect harness
      • Generator harness
      • Modbus monitoring of packages
      • Vandal proof panel door
    • Cooling System
      • Package mounted radiators
      • Remote radiators
      • Fuel cooler
    • Crankcase Systems
      • Explosive relief valves
      • Crankcase ventilation system
    • Exhaust System
      • Front housing - Standby or mission critical
      • Front housing - Prime or continuous
      • Exhaust collectors/manifold
      • Mufflers (15, 25 and 34 dBA)
    • Fuel System
      • Primary fuel filter
    • Generators and Attachments
      • Medium voltage - 3000 Frames - 50 Hz, 3 phase, 1500 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Thermostat for space heater
      • Generator air cleaner
      • Differential current transformers - (5, 9 and 15 kV Class)
    • Instrumentation
      • Pyrometer and thermocouples
    • Lube System
      • Lube oil heater
      • Lube oil heater with Crankcase explosion relief valves
      • Drain group oil pans
      • Lubricating oil
      • Electric prelube pumps
      • Oil filters
    • Mounting System
      • Rubber anti-vibration mounts
      • Spring type linear vibration isolators
      • IBC vibration isolators - Shipped loose
    • Special Tests / Reports
      • Generator test report
      • PGS Test report @ 1.0 power factor
      • PGS Test report @ 0.8 power factor
      • Standard genset TVA (Torsional Vibration Analysis) report
      • Custom generator TVA report
      • Special test charge - Engine only
      • Genset fuel consumption test
      • Standard engine test charge
    • Starting / Charging System
      • 24 Volt electric starting motor
      • Air starting motor
      • Air pressure regulator
      • Starter location covers
      • 24 Volt battery set - Dry
      • 20, 35 and 50 Amp Battery chargers
      • Charging alternators - Dry
      • Jacket water heaters
    • General
      • Special paint - 3500, Colors (other than Caterpillar yellow or high performance paints)
      • US aid emblem
      • Service tools
      • Engine barring group
      • Manual
      • Engine barring air powered
      • control GP - air powered bar group

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN