THIS IS MY SELECT

Maximum Rating

4000 ekW

Minimum Rating

3150 ekW

Emissions/Fuel Strategy

Low Fuel, Tier 2

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C175-20 SCAC, V-20, 4-Stroke Water-Cooled Diesel

    Bore

    6.89 in

    Stroke

    8.66 in

    Displacement

    6,456.31 in³

    Compression Ratio

    15.3:1

    Aspiration

    Turbo Aftercooled

    Fuel System

    Common Rail

    Governor Type

    ADEM� A4

    Generator Set Dimensions

    Length - Minimum

    262.5 in

    Length - Maximum

    331.1 in

    Width - Minimum

    92 in

    Width - Maximum

    128.5 in

    Height - Minimum

    99.8 in

    Height - Maximum

    150.7 in

    Dry Weight - Genset (minimum)

    55,100 lb

    Dry Weight - Genset (maximum)

    66,200 lb

    Generator Set Specifications

    Maximum Rating

    4000 ekW

    Minimum Rating

    3150 ekW

    Emissions/Fuel Strategy

    Low Fuel, Tier 2

    Voltage

    480 to 13800 Volts

    Frequency

    60 Hz

    Speed

    1800 rpm

    Duty Cycle

    Standby, Mission Critical, Prime, Continuous

    Standby Rating

    4000 (no fan)/3900/3620(no fan)/3500 ekW

    Prime Power Rating

    3600 (no fan)/3500/3300 (no fan)/3180 ekW

    • Air Inlet System
      • 4 x Single element air cleaner canisters with service indicator(s).
    • Control Panel
      • 24 Volt DC operation
      • 4 Programmable relay Inputs
      • 4 Programmable relay output
      • Alarm acknowledge
      • Amps (per phase & average)
      • Auto/start/stop control
      • Coolant temperature
      • DC volts
      • Digital indicators
      • Cat ECS 100
      • Emergency stop
      • Emergency stop pushbutton
      • Engine cool-down timer
      • Engine cycle crank
      • Environmental sealed front face
      • Failure to start (overcrank)
      • Frequency (Hz)
      • High Coolant temperature
      • Lamp test
      • Low coolant level
      • Low oil pressure
      • Oil pressure (psi, kPa or bar)
      • Operating hours
      • Overspeed
      • RPM
      • Speed adjust
      • Text alarm/event descriptions.
      • True RMS AC metering, 3-phase, +/-2% accuracy
      • Volts (L-L & L-N)
      • Wall mounted controls:
      • Warning/shutdown Indicators:
    • Cooling System
      • AC Inlet: 6" ANSI / AC Outlet: 3-1/2" ANSI
      • Coolant sensors
      • JW Inlet: 6" ANSI / JW Outlet: 5" Cat Flange
      • SCAC cooling
    • Exhaust System
      • Dry exhaust manifold
      • Dual ANSI 18" / DIN 450 flanges. Shipped loose. Support required from installation
    • Fuel System
      • 10 Micron spin on yype
      • 4 Micron spin on type
      • Engine mounted filters x 3
      • Filters x 3
      • Primary fuel filter water/fuel water separator
      • Secondary/tertiary fuel filters
    • Generators and attachments
      • 3 Phase brushless
      • 3 Phase voltage sensing
      • 6 Leads
      • Anti-condensation space heater
      • Class H temperature rise at 40C ambient
      • Exciter diode monitor
      • Form wound
      • IEC platinum stator RTDs
      • Min / max exciter limiter
      • NEMA Class H insulation
      • Permanent magnet excitation (PMG)
      • Reactive droop capability
      • RFI suppression
      • Right side extension box, bottom cable entry
      • Salient pole
      • Voltage regulator
    • Governing System
      • ADEM A4
      • Redundant shutdown (Overspeed protection through a duplicate speed sensing system)
    • Lube System
      • Fumes disposal
      • Gear type lube oil pump
      • Integral lube Oil cooler
      • Lubricating oil
      • Oil drain lines and valve
      • Oil filter, filler and dipstick
    • Mounting Systems
      • Rails - Engine/generator
      • Rubber anti-vibration mounts - shipped loose
    • Starting / Charging System
      • Batteries and battery rack w/cables
      • Battery disconnect switch
      • Dual 24 volt electric starting motors
    • General
      • Paint - Caterpillar yellow with high gloss black rails
      • Right hand servicing
      • SAE standard rotation

    • Air Inlet Systems
      • Single element air cleaner
    • Control Panel
      • EMCP 4.4
      • Controller and MV and HV power connection locations
      • Controller voltage and current sensing groups
      • E-Stop
      • Generator harness
      • Generator temperature monitoring
      • Interconnect harness
      • Load share module
      • Modbus monitoring of packages
      • Speed adjust
      • Vandal proof panel door
      • Annunciator modules
      • Customer interface options
    • Cooling System
      • Fuel cooler
      • Package mounted radiators
      • Remote radiators
    • Crankcase Systems
      • Crankcase ventilation system
      • Explosive relief valves
    • Exhaust System
      • Exhaust collectors/manifold
      • Front housing - Prime or continuous
      • Front housing - Standby or mission critical
      • Mufflers (15, 25 and 34 dBA silencers)
    • Fuel System
      • Primary fuel filter
    • Generator
      • Anti-condensation heater
      • Internal excitation (IE)
      • Oversize and premium generators
      • Permanent magnet excitation (PMG)
    • Generators and Attachments
      • Differential current transformers
      • Generator air cleaner
      • Medium voltage - 3000 Frames - 60 Hz, 3 phase, 1800 rpm, FW, PM, No of leads=6, Pitch 0.6667
      • Thermostat for space heater
    • Instrumentation
      • Pyrometer and thermocouples
    • Lube System
      • Drain group oil pans
      • Electric prelube pumps
      • Lube oil heater
      • Lubricating oil
      • Oil filters
    • Mounting System
      • IBC vibration isolators - Shipped loose
      • Rubber anti-vibration mounts
      • Spring type linear vibration isolators
    • Power Termination
      • Circuit breakers, IEC compliant
      • Circuit breakers, UL listed
    • Special Tests / Reports
      • Custom generator TVA report
      • Generator test report
      • Genset fuel consumption test
      • PGS Test report @ 0.8 power factor
      • PGS Test report @ 1.0 power factor
      • Special test charge - Engine only
      • Standard engine test charge
      • Standard genset TVA (Torsional Vibration Analysis) report
    • Starting / Charging System
      • 20 Amp Battery chargers
      • 24 Volt battery set - Dry
      • 24 Volt electric starting motor
      • 35 Amp Battery chargers
      • 50 Amp Battery chargers
      • Air pressure regulator
      • Air starting motor
      • Charging alternators - Dry
      • Jacket water heaters
      • Starter location covers
    • General
      • Barring groups:
      • Control GP - air powered bar group
      • Engine air powered
      • Engine barring group
      • Manual
      • Special paint - 3500