THIS IS MY SELECT

Diesel Generator Sets

C18 Generator Set

Maximum Rating

600 ekW

Minimum Rating

455 ekW

Emissions/Fuel Strategy

U.S. EPA Cert., Tier 2

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C18 ATAAC, I-6, 4-Stroke Water-Cooled Diesel

    Bore

    5.71 in

    Stroke

    7.2 in

    Displacement

    1,106.4 l

    Compression Ratio

    14.5:1

    Aspiration

    Air to Air Aftercooled

    Fuel System

    Electronic unit injection

    Governor Type

    Adem™A4

    Generator Set Dimensions

    Length - Maximum

    5,550 in

    Width - Maximum

    80.9 in

    Height - Maximum

    107.8 in

    Generator Set Specifications

    Maximum Rating

    600 ekW

    Minimum Rating

    455 ekW

    Emissions/Fuel Strategy

    U.S. EPA Cert., Tier 2

    Voltage

    208 to 600 Volts

    Frequency

    60 Hz

    Speed

    1800 rpm

    Duty Cycle

    Standby, Prime

    • Air Inlet
      • Air cleaner
    • Air Inlet System
      • Turbocharger
      • Light duty air cleaner
      • Aftercooler core
    • Cooling
      • Caterpillar extended life coolant
      • Fan drive, battery charging alternator drive
      • Coolant drain line with valve
      • Radiator and cooling fan with guard
      • Package mounted radiator
    • Exhaust
      • Exhaust flange outlet
    • Exhaust System
      • Stainless steel exhaust flex gaskets, raincap and SAE exhaust
        flange for customer use - shipped loose
    • Fuel System
      • Standard 8 hour open set fuel tank
    • Fuel
      • Secondary fuel filters
      • Fuel priming pump
      • Primary fuel filter with integral water separator
    • Generator and Attachments
      • Matched to the performance and output characteristics of Cat engines
      • Segregated low voltage (AC/DC) wiring panel
      • Power center, IP22
      • A Frame generator - IP21 protection
      • Integrated voltage regulator (IVR)
      • Mandatory option circuit breaker, IEC, 3 pole, mounted in power centre
      • Integrated voltage regulator (IVR)
    • Generator
      • IP23 Protection
      • Matched to the performance and output characteristics of Cat engines
      • Load adjustment module provides engine relief upon load impact and improves load acceptance and recovery time
    • Power Termination
      • Busbar
    • Control System
      • GCCP 1.2
    • Governing System
      • Cat electronic governor (ADEM A4)
    • Control Panel
      • EMCP 4 Genset controller
    • Lube System
      • Lubricating oil
      • Oil drain valves
    • Mounting System
      • Captive linear vibration isolators between base and engine-generator.
        includes lifting provisions and termination points for coolant
        and lube oil drain lines
    • Mounting
      • Rubber vibration isolators
    • Starting/Charging
      • 24 Volt battery with rack and cables
      • 24 volt starting motor
      • Batteries
    • General
      • Engine and alternator pre-paint, Caterpillar yellow
      • Paint - Caterpillar yellow except rails and radiators gloss black

    • Air Inlet System
      • Single element air cleaner
      • Dual element air cleaner
    • Exhaust
      • Industrial, residential, critical mufflers
    • Generator
      • Oversize and premium generators
      • Excitation: [ ] Permanent magnet excitation (PMG) Excited (PM) [ ] Internally Excited (IE)
      • Anti-condensation heater
    • Power Termination
      • Circuit breakers, UL listed
      • Circuit breakers, IEC compliant
    • Circuit breakers
      • 3 Pole (IEC-100% rated) Circuit breakers - Motorised
      • 4 Pole (IEC-100% rated) Circuit breakers - Motorised
      • Shunt trip for IEC breaker
      • Power terminal strip
      • Circuit breaker (IEC) Auxiliary contacts
      • 3 Pole (IEC-100% rated) Circuit breakers - Package mounted
      • Padlockable circuit breaker device
      • 4 Pole (IEC-100% rated) Circuit breakers - Package mounted
    • Control Panels
      • Remote monitoring software
      • Load share module
      • Local & remote annunciator modules
      • GCCP 1.2, GCCP 1.5
      • Digital I/O module
    • Control System
      • Local alarm modules
      • Volt free contact
      • Local alarm horn
      • Remote annunciator module
      • Oil temperature displays
      • Protective devices: Earth fault relay - earth leageage Ground fault relay - Overload shutdown via breaker - Low fuel level alarm - Low fuel level shutdown - High fuel level alarm - Fuel level sensor
      • GCCP 1.5
    • Cooling System
      • Low coolant temperature alarm
      • Radiator duct flange
    • Enclosures
      • Sound attenuated enclosures
    • Starting/Charging
      • Jacket water heater
      • Battery chargers
      • Heavy duty starting system
      • Oversize batteries
      • Charging alternator
    • Exhaust System
      • 8 and 10 inch GP flanges
      • 8 and 10 inch elbow kits
      • Engine mounted muffler
      • 10, 25 and 35 end in / end out mufflers
      • Manifold and turbocharger guards
    • Fuel System
      • Manual fuel transfer pump
      • Fuel transfer system
      • Integral - Dual wall fuel tank base
    • General
      • Sound attenuated, weather protective or high ambient weather protective enclosure
      • Integral & sub-base UL listed dual wall fuel tanks
      • CSA Certification
      • Automatic transfer switches (ATS)
      • The following options are based on regional and product configuration:
      • Single or dual wall sub-base fuel tanks
      • EU Certificate of Conformance (CE)
      • EEC Declaration of Conformity
      • UL 2200 package
      • Single or dual wall integral fuel tanks
      • Seismic Certification per applicable building codes: IBC 2000, IBC 2003, IBC 2006, IBC 2009, CBC 2007
      • Narrow, wide or skid base
      • Enclosures: Sound attenuated, weather protective
    • Generator and Attachments
      • Space heaters
      • A Frame CIP generator
      • Permanent magnet excitation (PMG)
      • LC frame generator
      • A Frame oversize generator
      • Ingress protection
      • LC frame CIP generator
      • LC frame oversize generators
    • Lube System
      • Manual sump pump
    • Starting and Charging
      • Battery disconnect switch
      • Jacket water heaters
      • 5 Amp Battery charger

    Similar Models

    WHY CHOOSE EMPIRE

    • Machines built tough and ready to run in rugged applications

    • Trusted advisors to help you find and maximize your equipment

    • Wide inventory of rental equipment that lets you try before you buy

    • Full service and support to ensure performance and longevity

    YOU MIGHT ALSO BE INTERESTED IN