THIS IS MY SELECT
C4.4 Generator Set
Maximum Rating
60 ekW
Minimum Rating
36 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
SPECIFICATIONS
Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.
Engine Specifications
Engine Model
C4.4, In-line 4, 4-cycle diesel
Bore
4.13 in
105 mm
Stroke
5 in
127 mm
Displacement
268.5 in
4.4 l
Compression Ratio
18.2:1
Aspiration
Turbocharged
Fuel System
Electronic (adjustable)
Governor Type
Adem™A4
Generator Set Dimensions
Length - Maximum
75.8 in
1,925 mm
Width - Maximum
44.1 in
1,120 mm
Height - Maximum
53.6 in
1,361 mm
Generator Set Specifications
Maximum Rating
60 ekW
Minimum Rating
36 ekW
Emissions/Fuel Strategy
U.S. EPA Cert., Tier 3
Voltage
208 to 600 Volts
Frequency
60 Hz
Speed
1800 rpm
Duty Cycle
Standby, Prime
- Certificates
- IBC seismic and wind Certifications
- Charging System
- NFPA battery charger UL10A 120VAC
- Air Inlet System
- Air cleaner
- Cartridge type air filter
- Circuit breakers
- Second circuit breaker box
- 3-Pole 100% rated
- Power terminal strip
- Breakers (100% UL rated)
- Control Panel
- 1000028996
- Exhaust System
- Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
- Fuel System
- Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
- Cooling System
- Coolant drain line with valve
- Radiator and cooling fan with guards
- Fan drive, battery charging alternator drive
- Caterpillar extended life coolant
- Radiator stone guard
- Generator
- 12 Leads
- Governing System
- Mechanical and electrical governing system - model dependent
- Lube System
- Oil drain line with valve
- Lubricating oil
- Control Panels
- WCA1 Low coolant temperature alarm
- WSS1 Low coolant level shut down
- FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
- NFPA110 bundle includes:
- PAA1 Panel mounted audible alarm
- A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
- Oil temperature gauge and sender
- PBC10NU NFPA battery charger
- Ground fault relay
- Discrete I/O module
- Volt free contacts genset run and common alarm
- Audible alarm
- Remote E-stop button
- Remote annunciator module
- Low coolant temperature alarm
- Protective devices:
- Overload shutdown via breaker
- Fuel level reading
- Low coolant level shutdown
- General
- Engine and alternator pre-paint, Caterpillar yellow
- Starting/Charging System
- 24V battery with rack and cables
- Batteries
- Certificates
- IBC seismic and wind Certifications
- Alternator System
- R Frame auxilliary winding
- Air Inlet System
- Cartridge type air filter
- Charging System
- NFPA battery charger UL10A 120VAC
- Circuit breakers
- 3-Pole 100% rated
- Breakers (100% UL rated)
- Second circuit breaker box
- Power terminal strip
- Control Panels
- Discrete I/O module
- Remote annunciator module
- Remote E-stop button
- Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
- Ground fault relay
- Audible alarm
- Oil temperature gauge and sender
- Volt free contacts genset run and common alarm
- NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required
when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
- Heating Elements
- Coolant heater
- Battery heater
- Anti-condensation heater
- Lube oil sump heater
- Jacket water heater
- Wiring for canopy space heater
- Cooling System
- Radiator transition flange
- Enclosures
- Panel viewing window
- External emergency stop
- Sound attenuated enclosure, Level 2
- Weatherproof enclosure
- Sound attenuated enclosure, Level 1
- Fuel System
- 5 Gallon fill containment
- Tank riser
- 209 and 394 gallon sub-base fuel tanks
- Emergency vent pipe
- 5 Gallon spill containment
- Mounting System
- Seismic vibration isolators
- Tests
- Generator test report
- PGS Test report @ 0.8 power factor
- 4 Hour factory test
- PGS Test report @ 1.0 power factor
- Exhaust System
- 10, 25 and 35 dBA silencer systems
- Overhead silencer mounting kit
- Generators
- Permanent magnet excitation (PMG) generator
Similar Models
WHY CHOOSE EMPIRE
-
Machines built tough and ready to run in rugged applications
-
Trusted advisors to help you find and maximize your equipment
-
Wide inventory of rental equipment that lets you try before you buy
-
Full service and support to ensure performance and longevity