Diesel Generator Sets

C4.4 Generator Set

Maximum Rating

60 ekW

Minimum Rating

36 ekW

Emissions/Fuel Strategy

U.S. EPA Cert., Tier 3

SPECIFICATIONS

Caterpillar is leading the power generation marketplace with Power Solutions engineered to deliver unmatched flexibility, expandability, reliability, and cost-effectiveness.

    Engine Specifications

    Engine Model

    C4.4, In-line 4, 4-cycle diesel

    Bore

    4.13 in

    Stroke

    in

    Displacement

    268.5 in

    Compression Ratio

    18.2:1

    Aspiration

    Turbocharged

    Fuel System

    Electronic (adjustable)

    Governor Type

    Adem™A4

    Generator Set Dimensions

    Length - Maximum

    75.8 in

    Width - Maximum

    44.1 in

    Height - Maximum

    53.6 in

    Generator Set Specifications

    Maximum Rating

    60 ekW

    Minimum Rating

    36 ekW

    Emissions/Fuel Strategy

    U.S. EPA Cert., Tier 3

    Voltage

    208 to 600 Volts

    Frequency

    60 Hz

    Speed

    1800 rpm

    Duty Cycle

    Standby, Prime

    • Certificates
      • IBC seismic and wind Certifications
    • Charging System
      • NFPA battery charger UL10A 120VAC
    • Air Inlet System
      • Air cleaner
      • Cartridge type air filter
    • Circuit breakers
      • Second circuit breaker box
      • 3-Pole 100% rated
      • Power terminal strip
      • Breakers (100% UL rated)
    • Control Panel
      • 1000028996
    • Exhaust System
      • Stub pipe, gaskets, raincap and SAE exhaust flange for customer use - shipped loose
    • Fuel System
      • Standard open set fuel tank/base supplied base, formed steel with single wall integral 8-hour fuel tank
    • Cooling System
      • Coolant drain line with valve
      • Radiator and cooling fan with guards
      • Fan drive, battery charging alternator drive
      • Caterpillar extended life coolant
      • Radiator stone guard
    • Generator
      • 12 Leads
    • Governing System
      • Mechanical and electrical governing system - model dependent
    • Lube System
      • Oil drain line with valve
      • Lubricating oil
    • Control Panels
      • WCA1 Low coolant temperature alarm
      • WSS1 Low coolant level shut down
      • FSS Low fuel level alarm & indication panel circuitry required when sub-base tank is selected
      • NFPA110 bundle includes:
      • PAA1 Panel mounted audible alarm
      • A Coolant heater, remote annunciator or 0.8 power factor test may be required depending on the application
      • Oil temperature gauge and sender
      • PBC10NU NFPA battery charger
      • Ground fault relay
      • Discrete I/O module
      • Volt free contacts genset run and common alarm
      • Audible alarm
      • Remote E-stop button
      • Remote annunciator module
      • Low coolant temperature alarm
      • Protective devices:
      • Overload shutdown via breaker
      • Fuel level reading
      • Low coolant level shutdown
    • General
      • Engine and alternator pre-paint, Caterpillar yellow
    • Starting/Charging System
      • 24V battery with rack and cables
      • Batteries

    • Certificates
      • IBC seismic and wind Certifications
    • Alternator System
      • R Frame auxilliary winding
    • Air Inlet System
      • Cartridge type air filter
    • Charging System
      • NFPA battery charger UL10A 120VAC
    • Circuit breakers
      • 3-Pole 100% rated
      • Breakers (100% UL rated)
      • Second circuit breaker box
      • Power terminal strip
    • Control Panels
      • Discrete I/O module
      • Remote annunciator module
      • Remote E-stop button
      • Protective devices: Low coolant temperature alarm - Low coolant level shutdown - Fuel level reading - Overload shutdown via breaker
      • Ground fault relay
      • Audible alarm
      • Oil temperature gauge and sender
      • Volt free contacts genset run and common alarm
      • NFPA110 bundle includes: FSS Low fuel level alarm & indication panel circuitry required
        when sub-base tank is selected - WSS1 Low coolant level shut down - WCA1 Low coolant temperature alarm - PAA1 Panel mounted audible alarm - PBC10NU NFPA battery charger - A Coolant heater ,remote annunciator or 0.8 power factor test may be required depending on the application
    • Heating Elements
      • Coolant heater
      • Battery heater
      • Anti-condensation heater
      • Lube oil sump heater
      • Jacket water heater
      • Wiring for canopy space heater
    • Cooling System
      • Radiator transition flange
    • Enclosures
      • Panel viewing window
      • External emergency stop
      • Sound attenuated enclosure, Level 2
      • Weatherproof enclosure
      • Sound attenuated enclosure, Level 1
    • Fuel System
      • 5 Gallon fill containment
      • Tank riser
      • 209 and 394 gallon sub-base fuel tanks
      • Emergency vent pipe
      • 5 Gallon spill containment
    • Mounting System
      • Seismic vibration isolators
    • Tests
      • Generator test report
      • PGS Test report @ 0.8 power factor
      • 4 Hour factory test
      • PGS Test report @ 1.0 power factor
    • Exhaust System
      • 10, 25 and 35 dBA silencer systems
      • Overhead silencer mounting kit
    • Generators
      • Permanent magnet excitation (PMG) generator